Zahra Parsa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zahra Parsa has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Mehrab Mehrvar
Department of Chemical Engineering Toronto Metropolitan University Toronto Ontario Canada
5 shared publications - Ramdhane Dhib
Department of Chemical Engineering, Toronto Metropolitan University, 350 Victoria Street, Toronto, ON M5B 2K3, Canada
3 shared publications - Chao Chang
Department of Chemical Engineering, Toronto Metropolitan University, 350 Victoria Street, Toronto, ON M5B 2K3, Canada
1 shared publication - Ramdhane Dhib
Department of Chemical Engineering, Ryerson University, 350 Victoria Street, Toronto, ON M5B 2K3, Canada
1 shared publication
Latest Publications
- Open Access
Feasibility and Statistical Analysis of Sulfanilic Acid Degradation in a Batch Photo-Fenton Process
Sulfanilic acid (SA) is a representative sulfonated aromatic amine commonly found in industrial effluents, posing significant risks to both human health and the ecosystem. Efficient and cost-effective treatment of SA-containing wastewater is crucial for sustainable environmental management. This study investigates the performance of the photo-Fenton process in degrading SA-containing wastewater. Three process variables are selected to study their effects on percent total organic carbon (%TOC) removal and final pH (pHFinal): initial total organic carbon concentration (TOC0) (150–250 mg/L), Fe2+ concentration (15–85 mg/L), and H2O2 concentration (1000–1500 mg/L). A combination of response surface methodology (RSM) and Box-Behnken design (BBD) is applied to examine both the individual and interactive effects of these variables. A total of 15 experimental trials are conducted, with the center point repeated three times. The results indicate significant interaction effects between Fe2+ and H2O2 concentrations on %TOC removal, while the interaction between TOC0 and H2O2 concentration notably influences pHFinal. The optimal operating parameters to maximize %TOC removal within 45 min of operation are determined as a TOC0 of 54.2 mg/L, an Fe2+ catalyst concentration of 33.7 mg/L, and an H2O2 concentration of 1403 mg/L. Under these conditions, the predicted %TOC removal and pHFinal were 89.2% and 2.93, respectively, which confirmed through validation experiments. Additionally, a correlation between pHFinal, TOC0, and final TOC concentration (TOCFinal) is observed, leading to the development of a linear model capable of predicting TOCFinal based on TOC0 and within the experimental space. The latter finding facilitates online monitoring of the process progress.Open AccessFeasibility and Statistical Analysis of Sulfanilic Acid Degradation in a Batch Photo-Fenton Process
Sulfanilic acid (SA) is a representative sulfonated aromatic amine commonly found in industrial effluents, posing significant risks to both human health and the ecosystem. Efficient and cost-effective treatment of SA-containing wastewater is crucial for sustainable environmental management. This study investigates the performance of the photo-Fenton process in degrading SA-containing wastewater. Three process variables are selected to study their effects on percent total organic carbon (%TOC) removal and final pH (pHFinal): initial total organic carbon concentration (TOC0) (150–250 mg/L), Fe2+ concentration (15–85 mg/L), and H2O2 concentration (1000–1500 mg/L). A combination of response surface methodology (RSM) and Box-Behnken design (BBD) is applied to examine both the individual and interactive effects of these variables. A total of 15 experimental trials are conducted, with the center point repeated three times. The results indicate significant interaction effects between Fe2+ and H2O2 concentrations on %TOC removal, while the interaction between TOC0 and H2O2 concentration notably influences pHFinal. The optimal operating parameters to maximize %TOC removal within 45 min of operation are determined as a TOC0 of 54.2 mg/L, an Fe2+ catalyst concentration of 33.7 mg/L, and an H2O2 concentration of 1403 mg/L. Under these conditions, the predicted %TOC removal and pHFinal were 89.2% and 2.93, respectively, which confirmed through validation experiments. Additionally, a correlation between pHFinal, TOC0, and final TOC concentration (TOCFinal) is observed, leading to the development of a linear model capable of predicting TOCFinal based on TOC0 and within the experimental space. The latter finding facilitates online monitoring of the process progress. - Open Access
- 4 May 2025
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 103 (12) , 6056-6071
pH and UVA real‐time data feasibility for monitoring aqueous PVA degradation in a continuous pilot‐scale UV / H 2 O 2 photoreactor: Experimental and statistical analysis
The performance of a continuous pilot‐scale UV/H 2 O 2 photoreactor for the degradation of aqueous polyvinyl alcohol (PVA) is studied. The process variables include PVA feed concentration, inlet H 2 O 2 concentration, and hydraulic retention time (HRT), ranging from 20 to 100 mg/L, 2 to 115 mg/L, and 5 to 25 min, respectively. Interactive effects of the input variables on the percentage of total organic carbon (TOC) removal, residual H 2 O 2 concentration, and effluent pH are analyzed using Latin hypercube sampling (LHS), quadratic modelling, and response surface methodology (RSM) in MATLAB and Design Expert. The process analysis determined optimal operating conditions of 22 mg/L PVA feed, 15 mg/L inlet H 2 O 2 concentration, and 24 min HRT, yielding a maximum TOC removal of 51.51% and a residual H 2 O 2 concentration of 5 mg/L. Despite previous studies, online pH and H 2 O 2 sensors are used in the experimental setup. A key novelty of this study is the identification and validation of reliable online indicators for parameters that cannot be measured online, enabling real‐time process monitoring and control. Specifically, UV absorbance of PVA feed solutions at 254 nm (UVA) exhibits a strong dependence on the PVA feed concentration, making it a reliable online indicator for monitoring PVA levels in the feed. Additionally, indicating a linear correlation between effluent pH and %TOC removal, with an R 2 value of 0.9886, suggests that effluent pH could serve as a reliable real‐time indicator of process removal performance. These findings highlight the potential of real‐time monitoring and optimization of UV/H 2 O 2 systems in large‐scale wastewater treatment applications.
- 4 May 2025
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 103 (12) , 6056-6071
Open AccesspH and UVA real‐time data feasibility for monitoring aqueous PVA degradation in a continuous pilot‐scale UV / H 2 O 2 photoreactor: Experimental and statistical analysis
The performance of a continuous pilot‐scale UV/H 2 O 2 photoreactor for the degradation of aqueous polyvinyl alcohol (PVA) is studied. The process variables include PVA feed concentration, inlet H 2 O 2 concentration, and hydraulic retention time (HRT), ranging from 20 to 100 mg/L, 2 to 115 mg/L, and 5 to 25 min, respectively. Interactive effects of the input variables on the percentage of total organic carbon (TOC) removal, residual H 2 O 2 concentration, and effluent pH are analyzed using Latin hypercube sampling (LHS), quadratic modelling, and response surface methodology (RSM) in MATLAB and Design Expert. The process analysis determined optimal operating conditions of 22 mg/L PVA feed, 15 mg/L inlet H 2 O 2 concentration, and 24 min HRT, yielding a maximum TOC removal of 51.51% and a residual H 2 O 2 concentration of 5 mg/L. Despite previous studies, online pH and H 2 O 2 sensors are used in the experimental setup. A key novelty of this study is the identification and validation of reliable online indicators for parameters that cannot be measured online, enabling real‐time process monitoring and control. Specifically, UV absorbance of PVA feed solutions at 254 nm (UVA) exhibits a strong dependence on the PVA feed concentration, making it a reliable online indicator for monitoring PVA levels in the feed. Additionally, indicating a linear correlation between effluent pH and %TOC removal, with an R 2 value of 0.9886, suggests that effluent pH could serve as a reliable real‐time indicator of process removal performance. These findings highlight the potential of real‐time monitoring and optimization of UV/H 2 O 2 systems in large‐scale wastewater treatment applications.
- Open Access
- 17 August 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (16) , 7060
Continuous UV/H2O2 Process: A Sustainable Wastewater Treatment Approach for Enhancing the Biodegradability of Aqueous PVA
Implementing efficient and cost-effective wastewater treatment methods in wastewater treatment plants (WWTPs) is crucial for ensuring sustainable development in contemporary societies. This study explores the feasibility of a continuous UV/ tubular photoreactor as a pre-treatment to enhance the biodegradability of aqueous polyvinyl alcohol (PVA) solutions, known as a nonbiodegradable wastewater. Using a combination of a Box–Behnken design (BBD) and the response surface methodology (RSM), three main process variables, including the PVA feed concentration, the inlet concentration, and the PVA feed flow rate, are studied within ranges of 500–1500 mg/L, 390–780 mg/L, and 50–150 mL/min, respectively. The results show significant interaction effects between the PVA feed and inlet concentrations on the effluent /COD ratio. The optimal operating conditions are determined using the RSM, with a PVA feed concentration of 665 mg/L, an inlet concentration of 390 mg/L, and a PVA feed flow rate of 59 mL/min. Operating at this point leads to an increase in the effluent /COD ratio from 0.15 to 0.53, which is validated experimentally with a ±5% error. Under these conditions, the effluent demonstrates an enhanced biodegradability, allowing for redirection to a subsequent biological post-treatment phase. This study demonstrates that using the UV/ process to enhance the biodegradability of an aqueous PVA solution is more economical than focusing on the complete removal of total organic carbon (TOC). Also, a comparison of these results with those of our previous study indicates that wastewater becomes more biodegradable by progressing the UV/ process due to the breakdown of polymer molecules, which reduces their molecular weight and makes them more consumable for biomass.- 17 August 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (16) , 7060
Open AccessContinuous UV/H2O2 Process: A Sustainable Wastewater Treatment Approach for Enhancing the Biodegradability of Aqueous PVA
Implementing efficient and cost-effective wastewater treatment methods in wastewater treatment plants (WWTPs) is crucial for ensuring sustainable development in contemporary societies. This study explores the feasibility of a continuous UV/ tubular photoreactor as a pre-treatment to enhance the biodegradability of aqueous polyvinyl alcohol (PVA) solutions, known as a nonbiodegradable wastewater. Using a combination of a Box–Behnken design (BBD) and the response surface methodology (RSM), three main process variables, including the PVA feed concentration, the inlet concentration, and the PVA feed flow rate, are studied within ranges of 500–1500 mg/L, 390–780 mg/L, and 50–150 mL/min, respectively. The results show significant interaction effects between the PVA feed and inlet concentrations on the effluent /COD ratio. The optimal operating conditions are determined using the RSM, with a PVA feed concentration of 665 mg/L, an inlet concentration of 390 mg/L, and a PVA feed flow rate of 59 mL/min. Operating at this point leads to an increase in the effluent /COD ratio from 0.15 to 0.53, which is validated experimentally with a ±5% error. Under these conditions, the effluent demonstrates an enhanced biodegradability, allowing for redirection to a subsequent biological post-treatment phase. This study demonstrates that using the UV/ process to enhance the biodegradability of an aqueous PVA solution is more economical than focusing on the complete removal of total organic carbon (TOC). Also, a comparison of these results with those of our previous study indicates that wastewater becomes more biodegradable by progressing the UV/ process due to the breakdown of polymer molecules, which reduces their molecular weight and makes them more consumable for biomass. - Top Cited PapersOpen Access
- 16 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (2) , 189
Dynamic Modelling, Process Control, and Monitoring of Selected Biological and Advanced Oxidation Processes for Wastewater Treatment: A Review of Recent Developments
This review emphasizes the significance of formulating control strategies for biological and advanced oxidation process (AOP)-based wastewater treatment systems. The aim is to guarantee that the effluent quality continuously aligns with environmental regulations while operating costs are minimized. It highlights the significance of understanding the dynamic behaviour of the process in developing effective control schemes. The most common process control strategies in wastewater treatment plants (WWTPs) are explained and listed. It is emphasized that the proper control scheme should be selected based on the process dynamic behaviour and control goal. This study further discusses the challenges associated with the control of wastewater treatment processes, including inadequacies in developed models, the limitations of most control strategies to the simulation stage, the imperative requirement for real-time data, and the financial and technical intricacies associated with implementing advanced controller hardware. It is discussed that the necessity of the availability of real-time data to achieve reliable control can be achieved by implementing proper, accurate hardware sensors in suitable locations of the process or by developing and implementing soft sensors. This study recommends further investigation on available actuators and the criteria for choosing the most appropriate one to achieve robust and reliable control in WWTPs, especially for biological and AOP-based treatment approaches.
- 16 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (2) , 189
Top Cited PapersOpen AccessDynamic Modelling, Process Control, and Monitoring of Selected Biological and Advanced Oxidation Processes for Wastewater Treatment: A Review of Recent Developments
This review emphasizes the significance of formulating control strategies for biological and advanced oxidation process (AOP)-based wastewater treatment systems. The aim is to guarantee that the effluent quality continuously aligns with environmental regulations while operating costs are minimized. It highlights the significance of understanding the dynamic behaviour of the process in developing effective control schemes. The most common process control strategies in wastewater treatment plants (WWTPs) are explained and listed. It is emphasized that the proper control scheme should be selected based on the process dynamic behaviour and control goal. This study further discusses the challenges associated with the control of wastewater treatment processes, including inadequacies in developed models, the limitations of most control strategies to the simulation stage, the imperative requirement for real-time data, and the financial and technical intricacies associated with implementing advanced controller hardware. It is discussed that the necessity of the availability of real-time data to achieve reliable control can be achieved by implementing proper, accurate hardware sensors in suitable locations of the process or by developing and implementing soft sensors. This study recommends further investigation on available actuators and the criteria for choosing the most appropriate one to achieve robust and reliable control in WWTPs, especially for biological and AOP-based treatment approaches.