Cangli Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cangli Liu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Chengjun Li
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
4 shared publications - Heli Ma
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang, China
4 shared publications - Jian Wu
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
4 shared publications - Jidong Weng
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
4 shared publications - Long Chen
Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
4 shared publications - Longhuang Tang
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang, China
4 shared publications
Latest Publications
- Open Access
- 24 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1732
Application of Highly Spatially Resolved Area Array Velocity Measurement in the Cracking Behavior of Materials
Understanding microscale dynamic behavior in heterogeneous materials (e.g., polycrystalline or semiconductor systems) under impact loading requires diagnostics capable of resolving ~100 μm features. This study introduces a 19-core fiber-optic array probe with 100 μm spatial resolution, integrated with DISAR velocimetry on a light gas gun platform, enabling two-dimensional continuous measurement of free-surface velocity. The system overcomes limitations of conventional single-point methods (e.g., VISAR’s millimeter-scale resolution and reflectivity constraints) by achieving nanosecond temporal resolution and sub-nanometer displacement sensitivity. Under ~8 GPa impact loading, the probe captures spatiotemporal velocity heterogeneity in polycrystalline materials, including localized pull-back signals and periodic oscillations caused by shock wave reflections at microstructural interfaces. These observations reveal dynamic processes such as damage initiation and evolution, directly linking velocity profiles to microscale material response. The results provide experimental evidence of how grain-scale defects influence shock propagation and energy dissipation, advancing predictive models for extreme-condition material performance. This high-resolution, multi-channel approach offers a paradigm shift in diagnosing heterogeneous material behavior under high-strain-rate loading.
- 24 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1732
Open AccessApplication of Highly Spatially Resolved Area Array Velocity Measurement in the Cracking Behavior of Materials
Understanding microscale dynamic behavior in heterogeneous materials (e.g., polycrystalline or semiconductor systems) under impact loading requires diagnostics capable of resolving ~100 μm features. This study introduces a 19-core fiber-optic array probe with 100 μm spatial resolution, integrated with DISAR velocimetry on a light gas gun platform, enabling two-dimensional continuous measurement of free-surface velocity. The system overcomes limitations of conventional single-point methods (e.g., VISAR’s millimeter-scale resolution and reflectivity constraints) by achieving nanosecond temporal resolution and sub-nanometer displacement sensitivity. Under ~8 GPa impact loading, the probe captures spatiotemporal velocity heterogeneity in polycrystalline materials, including localized pull-back signals and periodic oscillations caused by shock wave reflections at microstructural interfaces. These observations reveal dynamic processes such as damage initiation and evolution, directly linking velocity profiles to microscale material response. The results provide experimental evidence of how grain-scale defects influence shock propagation and energy dissipation, advancing predictive models for extreme-condition material performance. This high-resolution, multi-channel approach offers a paradigm shift in diagnosing heterogeneous material behavior under high-strain-rate loading.
- Open Access
- 21 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (23) , 10771
Measurement of Ultra-High Speed by Optical Multistage Cascade Frequency Reduction Technology
In order to reduce the frequency of high-frequency Doppler signal light, the electronic bandwidth of a data acquisition system is reduced. This paper mainly describes the principle and experimental verification results of optical multistage cascade frequency reduction technology. The bandwidth requirement of the detector and the oscilloscope is reduced by the method of “relaying” the measured beat frequency signal between multiple electronic channels. Aiming to achieve the requirement of ultra-high speed measurement of 22 km/s, the requirement of the original signal frequency as high as 28 GHz electrical bandwidth is reduced to the acquisition and recording system with only 8 GHz bandwidth. A complete velocity profile of up to 11.47 km/s is measured on a three-stage light gas gun with velocity measurement accuracy of 1%.
- 21 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (23) , 10771
Open AccessMeasurement of Ultra-High Speed by Optical Multistage Cascade Frequency Reduction Technology
In order to reduce the frequency of high-frequency Doppler signal light, the electronic bandwidth of a data acquisition system is reduced. This paper mainly describes the principle and experimental verification results of optical multistage cascade frequency reduction technology. The bandwidth requirement of the detector and the oscilloscope is reduced by the method of “relaying” the measured beat frequency signal between multiple electronic channels. Aiming to achieve the requirement of ultra-high speed measurement of 22 km/s, the requirement of the original signal frequency as high as 28 GHz electrical bandwidth is reduced to the acquisition and recording system with only 8 GHz bandwidth. A complete velocity profile of up to 11.47 km/s is measured on a three-stage light gas gun with velocity measurement accuracy of 1%.
- Open Access
- 20 September 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (9) , 1165
The Side-Release Method Measures the High-Pressure Sound Velocity of Iron Using Line-Spatially Resolved DISAR
The study of high-pressure sound velocity is an important part of shock wave physics, and the study of ultra-high pressure sound velocity of iron is of great significance to many research fields such as geophysics, solid state physics, and crystallography. At present, the measurement of sound velocity is usually carried out by the catch-up sparse wave method and windowed VISAR technology, which is complex in structure and not highly adaptable. In particular, for the ultra-high pressure sonic velocity measurement of metals, it is limited by the loading platform and window materials and cannot realize the high temperature and high-pressure environment of the earth’s inner core. In this paper, the sound velocity measurement of iron under high temperature and high-pressure environment (78 GPa) is realized based on the two-stage light gas cannon experimental platform. The side-side sparse wave method was used to establish a coupling model of high-spatially resolved optical group and fiber bundle. A multiplexed all-fiber laser interferometry velocity measurement system (DISAR) was built, and the spatial resolution was better than 20 μm. In this paper, we will provide a feasible route for a method for measuring the high spatiotemporal resolution velocity.
- 20 September 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (9) , 1165
Open AccessThe Side-Release Method Measures the High-Pressure Sound Velocity of Iron Using Line-Spatially Resolved DISAR
The study of high-pressure sound velocity is an important part of shock wave physics, and the study of ultra-high pressure sound velocity of iron is of great significance to many research fields such as geophysics, solid state physics, and crystallography. At present, the measurement of sound velocity is usually carried out by the catch-up sparse wave method and windowed VISAR technology, which is complex in structure and not highly adaptable. In particular, for the ultra-high pressure sonic velocity measurement of metals, it is limited by the loading platform and window materials and cannot realize the high temperature and high-pressure environment of the earth’s inner core. In this paper, the sound velocity measurement of iron under high temperature and high-pressure environment (78 GPa) is realized based on the two-stage light gas cannon experimental platform. The side-side sparse wave method was used to establish a coupling model of high-spatially resolved optical group and fiber bundle. A multiplexed all-fiber laser interferometry velocity measurement system (DISAR) was built, and the spatial resolution was better than 20 μm. In this paper, we will provide a feasible route for a method for measuring the high spatiotemporal resolution velocity.
- Open Access
Upconversion Photonic Doppler Velocimetry Based on Stimulated Brillouin Scattering
Optical up-conversion photonic Doppler velocimetry (PDV) based on stimulated Brillouin Scattering (SBS) with an all-fiber link structure is proposed in this article. Because SBS limits the laser power transmitted by a fiber over long distances, the probe does not have enough outgoing light to reach the measured surface and cannot receive the signal light. Traditionally, SBS is avoided, but it is a phase-conjugated light and shifts down relative to the source light, so it can be used as a reference light in the laser interference structure to achieve up-conversion heterodyne velocimetry. Compared with general homodyne velocimetry (DPS), SBS-PDV naturally upconverts and has more interference fringes and higher resolution at low-speed measurement. In the gas multiple reflection impact compression experiment, the velocity measurement results of SBS-PDV and dual-laser heterodyne Velocimetry (DLHV) are basically consistent, and the accuracy is better than 0.8%. Due to its coaxial heterodyne optical path, this kind of photonic Doppler velocimetry is suitable for low-velocity and long-distance practical applications in the field of shock wave physics.
Open AccessUpconversion Photonic Doppler Velocimetry Based on Stimulated Brillouin Scattering
Optical up-conversion photonic Doppler velocimetry (PDV) based on stimulated Brillouin Scattering (SBS) with an all-fiber link structure is proposed in this article. Because SBS limits the laser power transmitted by a fiber over long distances, the probe does not have enough outgoing light to reach the measured surface and cannot receive the signal light. Traditionally, SBS is avoided, but it is a phase-conjugated light and shifts down relative to the source light, so it can be used as a reference light in the laser interference structure to achieve up-conversion heterodyne velocimetry. Compared with general homodyne velocimetry (DPS), SBS-PDV naturally upconverts and has more interference fringes and higher resolution at low-speed measurement. In the gas multiple reflection impact compression experiment, the velocity measurement results of SBS-PDV and dual-laser heterodyne Velocimetry (DLHV) are basically consistent, and the accuracy is better than 0.8%. Due to its coaxial heterodyne optical path, this kind of photonic Doppler velocimetry is suitable for low-velocity and long-distance practical applications in the field of shock wave physics.