JEJuan Carlos Estrada

Juan Carlos Estrada

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Juan Carlos Estrada has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 2-Hydroxybenzylamine for Treatment of Atrial Fibrillation: A First-in-Human Clinical Pilot Trial

    by Zachary T. Yoneda, Matthew O’NEill, Diane M. Crawford, Mingfang Ao, Lili Sun, Majd A. El-Harasis, Lisa Pitchford, John A. Rathmacher, Jay Montgomery, Sharon T. Shen, et al.

    BACKGROUND: Inflammation is a common mechanism for atrial fibrillation (AF). 2-Hydroxybenzylamine (2-HOBA) is a novel therapeutic that scavenges isolevuglandins—a downstream mediator of inflammation and oxidative stress. 2-HOBA is safe and reduces AF in mice, prompting a first-in-human pilot clinical trial. METHODS: Participants were enrolled and randomized 1:1 to placebo or 2-HOBA (750 mg p.o. TID) 3 days before a planned AF ablation. Participants were monitored for 28 days after their ablation for recurrence of AF as detected by smartwatch single-lead ECG recordings. Blood was collected at the time of ablation for measurement of isolevuglandin levels. The study drug was stopped at 28 days. A 12-month extended follow-up period was used to monitor for any residual effect of the study drug on AF recurrence. RESULTS: 2-HOBA increased the risk of AF recurrence in the postablation population (odds ratio, 3.65 [95% CI, 1.31–10.16]; P =0.013) after prespecified adjustment for potential confounders. This increased risk of recurrence remained despite post hoc adjustment for other clinical risk factors. There was no difference in isolevuglandin levels between the 2-HOBA and placebo groups. After the study drug was stopped, there was no difference in AF recurrence between the 2-HOBA and placebo groups during the 12-month extended follow-up. CONCLUSIONS: 2-HOBA was associated with a higher risk of AF recurrence when tested early after AF ablation. This result was unexpected based on preclinical data, but paradoxical associations with AF have been previously reported for other drugs that target inflammation and oxidative stress pathways, such as omega-3 fatty acids. The mechanisms for AF immediately following ablation may be different from AF that occurs under other conditions, and the generalizability of these results to all forms of AF remains unknown.


  • Can Intracardiac Echocardiography Reduce Steam Pops During Half-Normal Saline Irrigated Radiofrequency Ablation?

    by Kanae Hasegawa, Zachary T. Yoneda, Jose R. Martines-Parachini, Edward M. Powers, Giovanni E. Davogustto, Tiffany Y. Hu, Kenichi Tokutake, Masaaki Kurata, Travis D. Richardson, Jay A. Montgomery, et al.

    BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% ( P P =0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P =0.004, and odds ratio, 29.93; P <0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.


  • Open Access

    Safety of ventricular arrhythmia radiofrequency ablation with half-normal saline irrigation

    by Kanae Hasegawa, Zachary T Yoneda, Edward M Powers, Kenichi Tokutake, Masaaki Kurata, Travis D Richardson, Jay A Montgomery, Sharon Shen, Juan C Estrada, Pablo J Saavedra, et al.

    Aims: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. Methods and results: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15 Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. Conclusion: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.