HMHevatib Mehmood

Hevatib Mehmood

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hevatib Mehmood has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Low early fixation failure rates with variable-angle locking plate fixation of AO/OTA 34 C patella fractures: a retrospective cohort study

    by Benyamin Dadpey, Kevin Zhu, Claire Bonnyman, Hevatib Mehmood, William T. Kent

    Purpose: To determine the fixation failure rate of the variable-angle (VA) locking patella plate and to evaluate whether supplemental augmentation reduced the risk of fixation failure. Methods: A retrospective comparative cohort study was performed at a Level I trauma center between January 2021 and June 2025. Adult patients with OTA/AO 34 C patella fractures treated with a VA locking plate with or without augmentation and ≥ 3 months of follow-up were included. Augmentation was defined as additional plates, independent screws, cerclage wire, heavy non absorbable sutures, or suture anchors that were used to supplement fixation and/or reinforce the inferior patellar pole or extensor mechanism. The primary outcome was fixation failure; secondary outcomes included mode of failure, infection and symptomatic implant removal. Results: Thirty-four patients were included (17 VA-only, 17 VA + augmentation). Groups were comparable for age, sex, Charlson Comorbidity Index, OTA/AO subclassification, open fracture status and follow-up duration (all p > 0.05). The overall fixation failure rate was 2.9% (1/34), occurring at the distal fixation interface in the augmented group. There was no significant difference in failure rate between groups (VA-only 0.0% vs. VA + augmentation 5.9%; p = 1.0). One patient in the VA group suffered a fracture-related infection and one patient in the VA + augmentation cohort had a suture abscess. One patient in the VA + augmentation cohort required hardware removal for symptomatic hardware. All remaining patients healed without complications. Conclusion: Variable-angle locking plate fixation of AO/OTA 34 C patella fractures was associated with low rates of early fixation failure and symptomatic hardware removal. With only a single documented fixation failure, the study was underpowered to draw conclusions regarding the protective role of augmentation on fixation failure.


  • Open Access

    The Usage-Trust Gap: Information Sources, Trust, and COVID-19 Knowledge Among American Indian and Alaska Native Adults in Rural Michigan

    by Maya Asami Takagi, Hevatib Mehmood, Asef Raiyan Hoque, Neli Ragina

    American Indian and Alaska Native (AI/AN) communities experienced disproportionate COVID-19 morbidity and mortality, particularly in rural areas with limited public health infrastructure. This study examined primary COVID-19 information sources among AI/AN adults in rural Michigan and evaluated how trust in these sources relates to health knowledge, attitudes, and vaccination behaviors. We conducted a prospective, randomized pre-post interventional study among 273 adults at a tribal health clinic in rural Isabella County, Michigan (2022–2024). Participants were assigned to receive a culturally tailored educational video or infographic, and surveys assessed COVID-19 knowledge, vaccine attitudes, information sources, and perceived reliability. Social media was the most frequently used information source but was rated as less reliable, whereas healthcare workers (HCWs) were considered the most trusted. Reliance on HCWs and personal relationships was associated with higher baseline vaccine knowledge and greater uptake of influenza vaccination. Both educational formats resulted in modest improvements in COVID-19 knowledge and vaccine attitudes. While no consistent differences were observed between formats overall, infographic-based education was associated with greater gains in select vaccine knowledge domains among participants who relied on trusted interpersonal or clinical information sources. These findings highlight a “usage-trust gap” in rural AI/AN health communication, where frequently used information channels are not necessarily the most trusted. Culturally tailored messaging delivered through trusted clinical and interpersonal networks may enhance the effectiveness of public health communication and support vaccine uptake in underserved communities.

  • Open Access

    High-resolution single-particle imaging at 100–200 keV with the Gatan Alpine direct electron detector

    by Lieza M. Chan, Brandon J. Courteau, Allison Maker, Mengyu Wu, Benjamin Basanta, Hev Mehmood, David Bulkley, David Joyce, Brian C. Lee, Stephen Mick, et al.


  • Open Access

    High-resolution single-particle imaging at 100-200 keV with the Gatan Alpine direct electron detector

    by Lieza M. Chan, Brandon J. Courteau, Allison Maker, Mengyu Wu, Benjamin Basanta, Hevatib Mehmood, David Bulkley, David Joyce, Brian C. Lee, Stephen Mick, et al.

    Developments in direct electron detector technology have played a pivotal role in enabling high-resolution structural studies by cryo-EM at 200 and 300 keV. Yet, theory and recent experiments indicate advantages to imaging at 100 keV, energies for which the current detectors have not been optimized. In this study, we evaluated the Gatan Alpine detector, designed for operation at 100 and 200 keV. Compared to the Gatan K3, Alpine demonstrated a significant DQE improvement at these voltages, specifically a ~4-fold improvement at Nyquist at 100 keV. In single-particle cryo-EM experiments, Alpine datasets yielded better than 2 Å resolution reconstructions of apoferritin at 120 and 200 keV on a ThermoFisher Scientific (TFS) Glacios microscope. We also achieved a ~3.2 Å resolution reconstruction for a 115 kDa asymmetric protein complex, proving its effectiveness with complex biological samples. In-depth analysis revealed that Alpine reconstructions are comparable to K3 reconstructions at 200 keV, and remarkably, reconstruction from Alpine at 120 keV on a TFS Glacios surpassed all but the 300 keV data from a TFS Titan Krios with GIF/K3. Additionally, we show Alpine’s capability for high-resolution data acquisition and screening on lower-end systems by obtaining ~3 Å resolution reconstructions of apoferritin and aldolase at 100 keV and detailed 2D averages of a 55 kDa sample using a side-entry cryo holder. Overall, we show that Gatan Alpine performs well with the standard 200 keV imaging systems and may potentially capture the benefits of lower accelerating voltages, possibly bringing smaller sized particles within the scope of cryo-EM.