High-resolution single-particle imaging at 100-200 keV with the Gatan Alpine direct electron detector
Authors:
- Lieza M. ChanLCLieza M. Chan
- Brandon J. CourteauBCBrandon J. Courteau
- Allison MakerAMAllison Maker
- Mengyu WuMWMengyu Wu
- Benjamin BasantaBBBenjamin Basanta
- Hevatib MehmoodHMHevatib Mehmood
- David BulkleyDBDavid Bulkley
- David JoyceDJDavid Joyce
- Brian C. LeeBLBrian C. Lee
- Stephen MickSMStephen Mick
- Sahil GulatiSGSahil Gulati
- Gabriel C. LanderGLGabriel C. Lander
Preprint
Abstract
Developments in direct electron detector technology have played a pivotal role in enabling high-resolution structural studies by cryo-EM at 200 and 300 keV. Yet, theory and recent experiments indicate advantages to imaging at 100 keV, energies for which the current detectors have not been optimized. In this study, we evaluated the Gatan Alpine detector, designed for operation at 100 and 200 keV. Compared to the Gatan K3, Alpine demonstrated a significant DQE improvement at these voltages, specifically a ~4-fold improvement at Nyquist at 100 keV. In single-particle cryo-EM experiments, Alpine datasets yielded better than 2 Å resolution reconstructions of apoferritin at 120 and 200 keV on a ThermoFisher Scientific (TFS) Glacios microscope. We also achieved a ~3.2 Å resolution reconstruction for a 115 kDa asymmetric protein complex, proving its effectiveness with complex biological samples. In-depth analysis revealed that Alpine reconstructions are comparable to K3 reconstructions at 200 keV, and remarkably, reconstruction from Alpine at 120 keV on a TFS Glacios surpassed all but the 300 keV data from a TFS Titan Krios with GIF/K3. Additionally, we show Alpine’s capability for high-resolution data acquisition and screening on lower-end systems by obtaining ~3 Å resolution reconstructions of apoferritin and aldolase at 100 keV and detailed 2D averages of a 55 kDa sample using a side-entry cryo holder. Overall, we show that Gatan Alpine performs well with the standard 200 keV imaging systems and may potentially capture the benefits of lower accelerating voltages, possibly bringing smaller sized particles within the scope of cryo-EM.Keywords
All Related Versions
- Published version: Journal of Structural Biology, 216 (3), 108108.
This publication has 53 references indexed in Scilit:
- Leginon: New features and applicationsProtein Science, 2020
- Precise beam-tilt alignment and collimation are required to minimize the phase error associated with coma in high-resolution cryo-EMJournal of Structural Biology, 2011
- Electron Energy-Loss Spectroscopy in the Electron Microscope2011
- The resolution dependence of optimal exposures in liquid nitrogen temperature electron cryomicroscopy of catalase crystalsJournal of Structural Biology, 2010
- Appion: An integrated, database-driven pipeline to facilitate EM image processingJournal of Structural Biology, 2009
- Automated electron microscope tomography using robust prediction of specimen movementsJournal of Structural Biology, 2005
- UCSF Chimera—A visualization system for exploratory research and analysisJournal of Computational Chemistry, 2004
- Optimal Determination of Particle Orientation, Absolute Hand, and Contrast Loss in Single-particle Electron CryomicroscopyJournal of Molecular Biology, 2003
- Electron radiation damage to protein crystals of bacteriorhodopsin at different temperaturesUltramicroscopy, 1996
- Molecular structure determination by electron microscopy of unstained crystalline specimensJournal of Molecular Biology, 1975