David Joyce
David Joyce has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Allison Maker
Cardiovascular Research Institute, University of California San Francisco; San Francisco, CA 94158, USA
1 shared publication - Benjamin Basanta
Department of Integrative Structural and Computational Biology, Scripps Research
1 shared publication - Brandon J. Courteau
Department of Cellular and Molecular Pharmacology, University of California
1 shared publication - Brian Lee
Gatan Inc., Pleasanton, CA, United States
1 shared publication C.P. Khattak
Crystal Syst. Inc., Salem, MA, USA
1 shared publication- David Bulkley
Department of Biochemistry and Biophysics, University of California, San Francisco, California 94158, USA
1 shared publication
Latest Publications
- Open Access
High-resolution single-particle imaging at 100-200 keV with the Gatan Alpine direct electron detector
Developments in direct electron detector technology have played a pivotal role in enabling high-resolution structural studies by cryo-EM at 200 and 300 keV. Yet, theory and recent experiments indicate advantages to imaging at 100 keV, energies for which the current detectors have not been optimized. In this study, we evaluated the Gatan Alpine detector, designed for operation at 100 and 200 keV. Compared to the Gatan K3, Alpine demonstrated a significant DQE improvement at these voltages, specifically a ~4-fold improvement at Nyquist at 100 keV. In single-particle cryo-EM experiments, Alpine datasets yielded better than 2 Å resolution reconstructions of apoferritin at 120 and 200 keV on a ThermoFisher Scientific (TFS) Glacios microscope. We also achieved a ~3.2 Å resolution reconstruction for a 115 kDa asymmetric protein complex, proving its effectiveness with complex biological samples. In-depth analysis revealed that Alpine reconstructions are comparable to K3 reconstructions at 200 keV, and remarkably, reconstruction from Alpine at 120 keV on a TFS Glacios surpassed all but the 300 keV data from a TFS Titan Krios with GIF/K3. Additionally, we show Alpine’s capability for high-resolution data acquisition and screening on lower-end systems by obtaining ~3 Å resolution reconstructions of apoferritin and aldolase at 100 keV and detailed 2D averages of a 55 kDa sample using a side-entry cryo holder. Overall, we show that Gatan Alpine performs well with the standard 200 keV imaging systems and may potentially capture the benefits of lower accelerating voltages, possibly bringing smaller sized particles within the scope of cryo-EM.
Open AccessHigh-resolution single-particle imaging at 100-200 keV with the Gatan Alpine direct electron detector
Developments in direct electron detector technology have played a pivotal role in enabling high-resolution structural studies by cryo-EM at 200 and 300 keV. Yet, theory and recent experiments indicate advantages to imaging at 100 keV, energies for which the current detectors have not been optimized. In this study, we evaluated the Gatan Alpine detector, designed for operation at 100 and 200 keV. Compared to the Gatan K3, Alpine demonstrated a significant DQE improvement at these voltages, specifically a ~4-fold improvement at Nyquist at 100 keV. In single-particle cryo-EM experiments, Alpine datasets yielded better than 2 Å resolution reconstructions of apoferritin at 120 and 200 keV on a ThermoFisher Scientific (TFS) Glacios microscope. We also achieved a ~3.2 Å resolution reconstruction for a 115 kDa asymmetric protein complex, proving its effectiveness with complex biological samples. In-depth analysis revealed that Alpine reconstructions are comparable to K3 reconstructions at 200 keV, and remarkably, reconstruction from Alpine at 120 keV on a TFS Glacios surpassed all but the 300 keV data from a TFS Titan Krios with GIF/K3. Additionally, we show Alpine’s capability for high-resolution data acquisition and screening on lower-end systems by obtaining ~3 Å resolution reconstructions of apoferritin and aldolase at 100 keV and detailed 2D averages of a 55 kDa sample using a side-entry cryo holder. Overall, we show that Gatan Alpine performs well with the standard 200 keV imaging systems and may potentially capture the benefits of lower accelerating voltages, possibly bringing smaller sized particles within the scope of cryo-EM.
- 31 October 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 364-367
Production of low-cost solar grade (SoG) silicon feedstock
- 31 October 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 364-367
Production of low-cost solar grade (SoG) silicon feedstock