Madeleine Eve Spellman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Madeleine Eve Spellman has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Matthias Wieland
Department of Population Medicine and Diagnostic Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853
10 shared publications - Ajay Singh
Department of Population Medicine and Diagnostic Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853
7 shared publications - Haritha Somula
Department of Population Medicine and Diagnostic Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853
6 shared publications - Carl Oskar Paulrud
DeLaval International, Tumba 14741, Sweden
2 shared publications - Christina Marie Geary
Department of Population Medicine and Diagnostic Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853
2 shared publications - Grace Frederick
Department of Population Medicine and Diagnostic Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853
2 shared publications
Latest Publications
- Open Access
- 1 December 2025
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 108 (12) , 13654-13666
An observational study investigating the association of teat condition with clinical mastitis risk
The objectives were to investigate the association between machine milking-induced teat tissue changes and the occurrence of clinical mastitis in Holstein dairy cows. We conducted 2 separate prospective cohort studies at 1 commercial dairy farm in New York State to study the association of machine milking-induced short-term changes (STC, trial 1) and machine milking-induced long-term changes (LTC, trial 2) with clinical mastitis occurrence. Each trial consisted of four 3-wk periods. On d 1 of each period, STC and LTC were assessed through visual inspection and manual palpation. Short-term teat tissue changes were assessed based on teat discoloration, the condition of the teat base, and the consistency of the teat end and categorized into a binary variable (STC present or absent). Long-term teat tissue changes were categorized into 4 groups as follows: no callosity present (score 1), callosity ring present with no or only mild roughness (score 2); callosity ring and roughness present with keratin fronds extending 1 to 3 mm from the teat orifice (score 3); and callosity ring present with excessive keratin fronds extending ≥4 mm from the teat orifice (score 4). Data on clinical mastitis occurrence was extracted from the herd management software. We used the first clinical mastitis event of a quarter for each 3-wk trial period and applied a 14-d gap to define a new mastitis case within a quarter between 2 trial periods. In trial 1, STC was documented in 6,110 of 66,702 cases (9.2%) over the four 3-wk periods, The frequency distribution of LTC in trial 2 was as follows: score 1 in 7,348 of 61,624 cases (11.9%), score 2 in 48,553 cases (78.8%), score 3 in 5,514 cases (8.9%), and score 4 in 209 cases (0.3%). We documented 944/66,702 (1.4%) clinical mastitis cases at the quarter level during trial 1 and 866/61,624 (1.4%) cases during trial 2. Generalized linear mixed models with a logit link and a binomial distribution were used to test if machine milking-induced teat tissue changes were associated with clinical mastitis occurrence. In trial 1, we analyzed 66,702 quarter-level observations from 5,094 cows. We found no significant association between STC and clinical mastitis occurrence. Compared with a quarter with a teat without STC, the odds (95% CI) of clinical mastitis were 1.22 (0.95-1.59). In trial 2, we used 61,624 quarter-level observations from 4,998 cows. We found no significant association between LTC and clinical mastitis occurrence. Compared with a quarter with a teat with a smooth end (score 1), the odds of a clinical mastitis case were 1.02 (0.77-1.36) for score 2, 1.19 (0.84-1.69) for score 3, and 2.14 (0.80-5.71) for score 4. We concluded that in the study cohort presented here, machine milking-induced teat tissue changes were not associated with the occurrence of clinical mastitis.
- 1 December 2025
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 108 (12) , 13654-13666
Open AccessAn observational study investigating the association of teat condition with clinical mastitis risk
The objectives were to investigate the association between machine milking-induced teat tissue changes and the occurrence of clinical mastitis in Holstein dairy cows. We conducted 2 separate prospective cohort studies at 1 commercial dairy farm in New York State to study the association of machine milking-induced short-term changes (STC, trial 1) and machine milking-induced long-term changes (LTC, trial 2) with clinical mastitis occurrence. Each trial consisted of four 3-wk periods. On d 1 of each period, STC and LTC were assessed through visual inspection and manual palpation. Short-term teat tissue changes were assessed based on teat discoloration, the condition of the teat base, and the consistency of the teat end and categorized into a binary variable (STC present or absent). Long-term teat tissue changes were categorized into 4 groups as follows: no callosity present (score 1), callosity ring present with no or only mild roughness (score 2); callosity ring and roughness present with keratin fronds extending 1 to 3 mm from the teat orifice (score 3); and callosity ring present with excessive keratin fronds extending ≥4 mm from the teat orifice (score 4). Data on clinical mastitis occurrence was extracted from the herd management software. We used the first clinical mastitis event of a quarter for each 3-wk trial period and applied a 14-d gap to define a new mastitis case within a quarter between 2 trial periods. In trial 1, STC was documented in 6,110 of 66,702 cases (9.2%) over the four 3-wk periods, The frequency distribution of LTC in trial 2 was as follows: score 1 in 7,348 of 61,624 cases (11.9%), score 2 in 48,553 cases (78.8%), score 3 in 5,514 cases (8.9%), and score 4 in 209 cases (0.3%). We documented 944/66,702 (1.4%) clinical mastitis cases at the quarter level during trial 1 and 866/61,624 (1.4%) cases during trial 2. Generalized linear mixed models with a logit link and a binomial distribution were used to test if machine milking-induced teat tissue changes were associated with clinical mastitis occurrence. In trial 1, we analyzed 66,702 quarter-level observations from 5,094 cows. We found no significant association between STC and clinical mastitis occurrence. Compared with a quarter with a teat without STC, the odds (95% CI) of clinical mastitis were 1.22 (0.95-1.59). In trial 2, we used 61,624 quarter-level observations from 4,998 cows. We found no significant association between LTC and clinical mastitis occurrence. Compared with a quarter with a teat with a smooth end (score 1), the odds of a clinical mastitis case were 1.02 (0.77-1.36) for score 2, 1.19 (0.84-1.69) for score 3, and 2.14 (0.80-5.71) for score 4. We concluded that in the study cohort presented here, machine milking-induced teat tissue changes were not associated with the occurrence of clinical mastitis.
- Open Access
- 1 September 2025
- Published by American Dairy Science Association in JDS Communications
- Vol. 6 (5) , 654-659
Lag time from calving to first colostrum harvest in Holstein dairy cows: Association with colostral immunoglobulin G, volume, and dry matter
Summary: First-milking colostrum samples (n = 640) were collected from Holstein cows up to 18 hours after calving. Colostrum yield was recorded, and colostrum samples were analyzed for immunoglobulin G (IgG) concentration and dry matter (DM). Total IgG yield was calculated from colostrum yield and concentration for each sample. A lag time of over 9 hours from calving to milking was associated with a decrease in colostral IgG concentration and DM. Total IgG yield did not change over time. When stored, high-quality colostrum is available to feed the newborn calf immediately after birth, first milking of colostrum can be delayed up to 9 hours without significant reduction in IgG concentration. A dilution effect was measurable after 9 hours.
- 1 September 2025
- Published by American Dairy Science Association in JDS Communications
- Vol. 6 (5) , 654-659
Open AccessLag time from calving to first colostrum harvest in Holstein dairy cows: Association with colostral immunoglobulin G, volume, and dry matter
Summary: First-milking colostrum samples (n = 640) were collected from Holstein cows up to 18 hours after calving. Colostrum yield was recorded, and colostrum samples were analyzed for immunoglobulin G (IgG) concentration and dry matter (DM). Total IgG yield was calculated from colostrum yield and concentration for each sample. A lag time of over 9 hours from calving to milking was associated with a decrease in colostral IgG concentration and DM. Total IgG yield did not change over time. When stored, high-quality colostrum is available to feed the newborn calf immediately after birth, first milking of colostrum can be delayed up to 9 hours without significant reduction in IgG concentration. A dilution effect was measurable after 9 hours.
- Open Access
- 1 January 2025
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 108 (1) , 773-780
The association between teat shape and clinical mastitis
Conformational teat traits such as teat-barrel shape and teat-end shape have long been recognized as possible risk factors for elevated somatic cell count and clinical mastitis in dairy cows. However, the association between udder health and these teat traits is still under debate. Our objective with this ambidirectional cohort study was to investigate the relationship between teat shape and the occurrence of clinical mastitis in dairy cows. For this purpose, we analyzed quarter-level data from 14,948 quarters of 3,913 Holstein cows from 1 commercial dairy farm in New York State. Cows were milked 3 times daily, housed in freestall pens, bedded with manure solids, and fed a TMR. Teat shape was assessed visually and classified based on teat-barrel and teat-end shape into 1 of 4 categories as follows: (1) triangular barrel and pointed teat end (TP), (2) square barrel and round teat end (SR), (3) square barrel, round teat end, and flat in the area of the teat orifice (SRF), and (4) square barrel and flat teat end (SF). Data on the occurrence of clinical mastitis were obtained from the dairy management software. To test the hypothesis that teat shape was associated with the occurrence of the first clinical mastitis event during the first 305 d in milk, a multivariable semiparametric proportional hazards model was built. Our results showed that teat shape was associated with the occurrence of clinical mastitis. Compared with SR, the clinical mastitis hazards (95% CI) were TP, 1.66 (1.25-2.19); SF, 1.58 (1.14-2.18); and SRF, 1.05 (0.88-1.26). We conclude that teat shape could be useful to identify cows at increased risk of clinical mastitis. This could allow farmers to employ targeted monitoring of these high-risk animals and develop management strategies that mitigate their risk.
- 1 January 2025
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 108 (1) , 773-780
Open AccessThe association between teat shape and clinical mastitis
Conformational teat traits such as teat-barrel shape and teat-end shape have long been recognized as possible risk factors for elevated somatic cell count and clinical mastitis in dairy cows. However, the association between udder health and these teat traits is still under debate. Our objective with this ambidirectional cohort study was to investigate the relationship between teat shape and the occurrence of clinical mastitis in dairy cows. For this purpose, we analyzed quarter-level data from 14,948 quarters of 3,913 Holstein cows from 1 commercial dairy farm in New York State. Cows were milked 3 times daily, housed in freestall pens, bedded with manure solids, and fed a TMR. Teat shape was assessed visually and classified based on teat-barrel and teat-end shape into 1 of 4 categories as follows: (1) triangular barrel and pointed teat end (TP), (2) square barrel and round teat end (SR), (3) square barrel, round teat end, and flat in the area of the teat orifice (SRF), and (4) square barrel and flat teat end (SF). Data on the occurrence of clinical mastitis were obtained from the dairy management software. To test the hypothesis that teat shape was associated with the occurrence of the first clinical mastitis event during the first 305 d in milk, a multivariable semiparametric proportional hazards model was built. Our results showed that teat shape was associated with the occurrence of clinical mastitis. Compared with SR, the clinical mastitis hazards (95% CI) were TP, 1.66 (1.25-2.19); SF, 1.58 (1.14-2.18); and SRF, 1.05 (0.88-1.26). We conclude that teat shape could be useful to identify cows at increased risk of clinical mastitis. This could allow farmers to employ targeted monitoring of these high-risk animals and develop management strategies that mitigate their risk.
- Open Access
- 1 December 2024
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 107 (12) , 11744-11760
Effects of flow-responsive vacuum and pulsation with early attachment of the milking unit on teat tissue condition and milking performance in Holstein dairy cows
The objectives of this study were to assess the effect of flow-responsive vacuum and pulsation, in conjunction with the early attachment of the milking unit (TRT), on teat tissue conditions and milking characteristics in dairy cows. In a switch-back trial, 5,235 Holstein cows milked 3 times daily in a rotary parlor were assigned to the TRT or control (CON) group. The trial lasted 84 d and was comprised of 4 alternating 3-week periods of TRT and CON. For both groups, premilking udder preparation consisted of teat brushing, forestripping and predipping, and wiping of teats, resulting in a stimulation time of 4 s. In the TRT group, the preparation lag time was 58 s, and in the CON group, it was 91 s for early- and mid-lactation cows and 105 s for late-lactation animals. Upon milking unit attachment, the TRT cows were milked at a lower vacuum (37.6 kPa) and pulsation (50 cycles/min, pulsation ratio of 30:70). The vacuum and pulsation settings were changed to milking mode when the milk flow reached 0.5 kg/min (pulsation switch-point) and 1.6 kg/min (vacuum switch-point). For milking mode, the vacuum setting was 47.7 kPa, and the pulsation rate was 60 cycles/min at a ratio of 65:35. The CON cows were milked with a flow-responsive vacuum, using the same vacuum settings as the TRT group. We assessed machine milking-induced short-term teat tissue changes and teat-end hyperkeratosis by palpation and visual inspection postmilking. Electronic on-farm milk meters were used to assess milking characteristics. Generalized linear mixed models were used to analyze the effect of treatment on the outcome variables. Compared with cows in group CON, the odds ratios (95% confidence interval; 95% CI) of short-term teat-tissue changes in early-, mid-, and late lactation cows in group TRT were 0.62 (0.52-0.76), 0.61 (0.48-0.77), and 0.93 (0.76-1.14), respectively. The least squares means [LSM, (95% CI)] for milking unit-on time in early-, mid-, and late lactation animals, respectively, were 251 (248-253), 236 (234-238), and 220 (218-222) s for group TRT and 247 (245-249), 232 (230-234), and 214 (213-216) s for the CON group. The LSM (95% CI) of peak milk flow rate in early-, mid-, and late lactation animals, respectively, were 5.75 (5.68-5.82), 5.77 (5.70-5.84), and 5.54 (5.48-5.59) kg/min for the TRT cows and 5.65 (5.58-5.72), 5.74 (5.68-5.81), and 5.45 (5.40-5.51) kg/min for the CON cows. The odds ratios (95% CI) of forced take-off in group TRT for early-, mid-, and late lactation cows, respectively, were 0.39 (0.37-0.41), 0.32 (0.30-0.34), and 0.47 (0.44-0.52) compared with their respective CON groups. In this study, cows that were milked using flow-responsive vacuum and pulsation with early attachment of the milking unit had lower odds of short-term teat tissue changes and forced take-off, as well as a higher peak milk flow rate. Our data suggest that the application of flow-responsive vacuum and pulsation facilitates early attachment of the milking unit, improves teat tissue condition, and has the potential to improve parlor efficiency.
- 1 December 2024
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 107 (12) , 11744-11760
Open AccessEffects of flow-responsive vacuum and pulsation with early attachment of the milking unit on teat tissue condition and milking performance in Holstein dairy cows
The objectives of this study were to assess the effect of flow-responsive vacuum and pulsation, in conjunction with the early attachment of the milking unit (TRT), on teat tissue conditions and milking characteristics in dairy cows. In a switch-back trial, 5,235 Holstein cows milked 3 times daily in a rotary parlor were assigned to the TRT or control (CON) group. The trial lasted 84 d and was comprised of 4 alternating 3-week periods of TRT and CON. For both groups, premilking udder preparation consisted of teat brushing, forestripping and predipping, and wiping of teats, resulting in a stimulation time of 4 s. In the TRT group, the preparation lag time was 58 s, and in the CON group, it was 91 s for early- and mid-lactation cows and 105 s for late-lactation animals. Upon milking unit attachment, the TRT cows were milked at a lower vacuum (37.6 kPa) and pulsation (50 cycles/min, pulsation ratio of 30:70). The vacuum and pulsation settings were changed to milking mode when the milk flow reached 0.5 kg/min (pulsation switch-point) and 1.6 kg/min (vacuum switch-point). For milking mode, the vacuum setting was 47.7 kPa, and the pulsation rate was 60 cycles/min at a ratio of 65:35. The CON cows were milked with a flow-responsive vacuum, using the same vacuum settings as the TRT group. We assessed machine milking-induced short-term teat tissue changes and teat-end hyperkeratosis by palpation and visual inspection postmilking. Electronic on-farm milk meters were used to assess milking characteristics. Generalized linear mixed models were used to analyze the effect of treatment on the outcome variables. Compared with cows in group CON, the odds ratios (95% confidence interval; 95% CI) of short-term teat-tissue changes in early-, mid-, and late lactation cows in group TRT were 0.62 (0.52-0.76), 0.61 (0.48-0.77), and 0.93 (0.76-1.14), respectively. The least squares means [LSM, (95% CI)] for milking unit-on time in early-, mid-, and late lactation animals, respectively, were 251 (248-253), 236 (234-238), and 220 (218-222) s for group TRT and 247 (245-249), 232 (230-234), and 214 (213-216) s for the CON group. The LSM (95% CI) of peak milk flow rate in early-, mid-, and late lactation animals, respectively, were 5.75 (5.68-5.82), 5.77 (5.70-5.84), and 5.54 (5.48-5.59) kg/min for the TRT cows and 5.65 (5.58-5.72), 5.74 (5.68-5.81), and 5.45 (5.40-5.51) kg/min for the CON cows. The odds ratios (95% CI) of forced take-off in group TRT for early-, mid-, and late lactation cows, respectively, were 0.39 (0.37-0.41), 0.32 (0.30-0.34), and 0.47 (0.44-0.52) compared with their respective CON groups. In this study, cows that were milked using flow-responsive vacuum and pulsation with early attachment of the milking unit had lower odds of short-term teat tissue changes and forced take-off, as well as a higher peak milk flow rate. Our data suggest that the application of flow-responsive vacuum and pulsation facilitates early attachment of the milking unit, improves teat tissue condition, and has the potential to improve parlor efficiency.
- Open Access
- 1 December 2024
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 107 (12) , 11681-11696
A randomized controlled trial to study the effect of supplemental premilking stimulation on milking performance, teat tissue condition, udder health, and well-being in dairy cows
The objectives of this study were to evaluate the effect of supplemental premilking stimulation, provided after manual stimulation, by means of high-frequency pulsation without reduction of the vacuum in the pulsation chamber on milking performance, teat tissue condition, udder health, and well-being in dairy cows. In a randomized controlled trial, Holstein cows (n = 491) from 1 commercial dairy farm with a thrice-per-day milking schedule were assigned to treatment and control groups over a 64-d period. Treatments consisted of a maximum of 20 s of pulsation stimulation at a pulsation rate of 100 (SPS100) or 300 (SPS300) cycles per minute and a pulsation ratio of 25:75, which were applied after completion of manual premilking stimulation upon milking unit attachment. Cows in the control group (CON) received only traditional premilking stimulation by manual forestripping for 6 s, and wiping. Milking characteristics were measured with on-farm milk flow meters. Milking machine-induced short-term (swelling at teat base, firmness at teat end, and teat discoloration) and long-term (teat-end callosity) changes to the teat tissue were assessed manually and visually. Composite milk samples were analyzed for somatic cell counts. Cow hind-leg activity was assessed with 3-dimensional accelerometers. Fecal 11,17-dioxoandrostanes (11,17-DOAs; a group of cortisol metabolites) were determined on wk 4 and 8 to assess the well-being of the cows. Generalized linear mixed models were used to study the effect of treatments on the outcome variables milk yield/milking and milking unit-on time. We observed no meaningful differences among groups for milk yield or milking unit-on time. Least squares means and their 95% confidence intervals (95% CI) for cows in the SPS100, SPS300, and CON groups were 13.9 (13.3-14.5), 14.0 (13.4-14.6), and 13.9 (13.3-14.6) kg for milk yield and 218 (212-224), 218 (211-224), and 218 (212-224) s for milking unit-on time, respectively. Compared with cows in the CON group, the odds (95% CI) of short-term changes were 1.30 (0.95-1.78) for the SPS100 group and 1.50 (1.10-2.05) for the SPS300 group. The odds of long-term changes were 0.94 (0.67-1.34) for cows in the SPS100 group and 0.71 (0.49-1.04) for cows in the SPS300 group. We observed no differences in SCC. In reference to the CON group, the hazard ratio (95% CI) in SPS100 and SPS300, respectively, were 0.35 (0.13-0.98) and 1.22 (0.57-2.64) for clinical mastitis, and 0.34 (0.12-0.95) and 1.28 (0.60-2.73) for culling. The least squares means (95% CI) of hind-leg activity during milking were 8.3 (6.5-10.5), 10.6 (8.1-13.7), and 9.1 (7.2-11.6) movements per milking for the SPS100, SPS300, and CON groups, respectively. The least squares means (95% CI) of fecal 11,17-DOAs concentration (ng/g) at the first and second test days, respectively, were 31.1 (28.1-34.2) and 22.3 (19.2-25.4) for the SPS100 group, 26.4 (23.4-29.4) and 25.2 (22.0-28.4) for the SPS300 group, and 24.8 (21.8-27.9) and 25.0 (21.7-28.3) for the CON group. We conclude that applying supplemental stimulation after manual stimulation through the high-frequency pulsation system tested here did not impart additional benefits to the milk harvesting process, teat tissue condition, somatic cell count, or the well-being of the animals.
- 1 December 2024
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 107 (12) , 11681-11696
Open AccessA randomized controlled trial to study the effect of supplemental premilking stimulation on milking performance, teat tissue condition, udder health, and well-being in dairy cows
The objectives of this study were to evaluate the effect of supplemental premilking stimulation, provided after manual stimulation, by means of high-frequency pulsation without reduction of the vacuum in the pulsation chamber on milking performance, teat tissue condition, udder health, and well-being in dairy cows. In a randomized controlled trial, Holstein cows (n = 491) from 1 commercial dairy farm with a thrice-per-day milking schedule were assigned to treatment and control groups over a 64-d period. Treatments consisted of a maximum of 20 s of pulsation stimulation at a pulsation rate of 100 (SPS100) or 300 (SPS300) cycles per minute and a pulsation ratio of 25:75, which were applied after completion of manual premilking stimulation upon milking unit attachment. Cows in the control group (CON) received only traditional premilking stimulation by manual forestripping for 6 s, and wiping. Milking characteristics were measured with on-farm milk flow meters. Milking machine-induced short-term (swelling at teat base, firmness at teat end, and teat discoloration) and long-term (teat-end callosity) changes to the teat tissue were assessed manually and visually. Composite milk samples were analyzed for somatic cell counts. Cow hind-leg activity was assessed with 3-dimensional accelerometers. Fecal 11,17-dioxoandrostanes (11,17-DOAs; a group of cortisol metabolites) were determined on wk 4 and 8 to assess the well-being of the cows. Generalized linear mixed models were used to study the effect of treatments on the outcome variables milk yield/milking and milking unit-on time. We observed no meaningful differences among groups for milk yield or milking unit-on time. Least squares means and their 95% confidence intervals (95% CI) for cows in the SPS100, SPS300, and CON groups were 13.9 (13.3-14.5), 14.0 (13.4-14.6), and 13.9 (13.3-14.6) kg for milk yield and 218 (212-224), 218 (211-224), and 218 (212-224) s for milking unit-on time, respectively. Compared with cows in the CON group, the odds (95% CI) of short-term changes were 1.30 (0.95-1.78) for the SPS100 group and 1.50 (1.10-2.05) for the SPS300 group. The odds of long-term changes were 0.94 (0.67-1.34) for cows in the SPS100 group and 0.71 (0.49-1.04) for cows in the SPS300 group. We observed no differences in SCC. In reference to the CON group, the hazard ratio (95% CI) in SPS100 and SPS300, respectively, were 0.35 (0.13-0.98) and 1.22 (0.57-2.64) for clinical mastitis, and 0.34 (0.12-0.95) and 1.28 (0.60-2.73) for culling. The least squares means (95% CI) of hind-leg activity during milking were 8.3 (6.5-10.5), 10.6 (8.1-13.7), and 9.1 (7.2-11.6) movements per milking for the SPS100, SPS300, and CON groups, respectively. The least squares means (95% CI) of fecal 11,17-DOAs concentration (ng/g) at the first and second test days, respectively, were 31.1 (28.1-34.2) and 22.3 (19.2-25.4) for the SPS100 group, 26.4 (23.4-29.4) and 25.2 (22.0-28.4) for the SPS300 group, and 24.8 (21.8-27.9) and 25.0 (21.7-28.3) for the CON group. We conclude that applying supplemental stimulation after manual stimulation through the high-frequency pulsation system tested here did not impart additional benefits to the milk harvesting process, teat tissue condition, somatic cell count, or the well-being of the animals.
- Open Access
- 1 September 2024
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 107 (9) , 7469-7481
Effect of oxytocin use during colostrum harvest and the association of cow characteristics with colostrum yield and immunoglobulin G concentration in Holstein dairy cows
Our objectives were to determine the effect of oxytocin use during colostrum harvest on colostrum yield and IgG concentration in Holstein dairy cows on a commercial dairy in New York and to describe associations of cow characteristics with these outcomes. Animals were enrolled between July and October 2023 using a randomized block design, with day of enrollment as the unit of randomization. A median (range) of 10 (3-19) cows were enrolled per day. Treatments were (1) 40 IU oxytocin (OXY40), (2) 20 IU oxytocin (OXY20), and (3) an untreated control group (CNTR). Oxytocin was administered i.m. ∼45 s before unit attachment in a rotary parlor. Colostrum weight was measured using the colostrum bucket-embedded scale or a platform scale when the yield was less than the smallest bucket scale. The concentration of IgG ([IgG]) in colostrum was determined using radial immunodiffusion and used to calculate total IgG, and DM (%) was determined by oven drying. Individual cow characteristics such as parity, calf sex, weight, dystocia score, stillbirth, and milk production in wk 4 of lactation; additionally, for multiparous cows, dry period length and previous lactation dry-off linear SCS were collected. Data were analyzed separately for primiparous and multiparous cows using backward stepwise elimination. To produce final mixed effects ANOVA models, primiparous cows (n = 201) were randomized to 35.8% (n = 72) OXY40, 32.8% (n = 66) OXY20, and 31.3% (n = 63) CNTR. Multiparous groups (n = 435) were randomized to 34.7% (n = 151) OXY40, 29.7% (n = 129) OXY20, and 35.6% (n = 155) CNTR. The median (range) colostrum yield was 6.0 (0-20.6) kg and [IgG] was 98.5 (0.1-293.6) g/L in the study population. In primiparous cows, OXY40 had a higher colostrum yield (LSM [95% CI]) of 5.4 (4.9-5.9) kg compared with both OXY20 (4.1 [3.5-4.7] kg) and CNTR (3.8 [3.3-4.3] kg). In multiparous cows, OXY40, OXY20, and CNTR did not differ in colostrum yield (5.9 [5.3-6.5], 5.7 [5.1-6.3], and 5.4 [4.8-6.0] kg, respectively), but colostrum yield was greater in parity 2 compared with all other parities, cows giving birth to male calves, cows with the highest milk production at wk 4 of lactation, and cows with a dry period of >65 d. Oxytocin use did not affect [IgG] in either primiparous or multiparous cows, but [IgG] was highest in cows in parity ≥4 and lowest in cows dry >65 d. In summary, oxytocin use at 40 IU i.m. was associated with a higher colostrum yield in primiparous cows only and no change in [IgG]. Oxytocin use likely addressed disturbed milk ejection and therefore increased colostrum yield in heifers milked for the first time in a rotary parlor. This study confirms cow characteristics associated with colostrum production within a single herd.
- 1 September 2024
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 107 (9) , 7469-7481
Open AccessEffect of oxytocin use during colostrum harvest and the association of cow characteristics with colostrum yield and immunoglobulin G concentration in Holstein dairy cows
Our objectives were to determine the effect of oxytocin use during colostrum harvest on colostrum yield and IgG concentration in Holstein dairy cows on a commercial dairy in New York and to describe associations of cow characteristics with these outcomes. Animals were enrolled between July and October 2023 using a randomized block design, with day of enrollment as the unit of randomization. A median (range) of 10 (3-19) cows were enrolled per day. Treatments were (1) 40 IU oxytocin (OXY40), (2) 20 IU oxytocin (OXY20), and (3) an untreated control group (CNTR). Oxytocin was administered i.m. ∼45 s before unit attachment in a rotary parlor. Colostrum weight was measured using the colostrum bucket-embedded scale or a platform scale when the yield was less than the smallest bucket scale. The concentration of IgG ([IgG]) in colostrum was determined using radial immunodiffusion and used to calculate total IgG, and DM (%) was determined by oven drying. Individual cow characteristics such as parity, calf sex, weight, dystocia score, stillbirth, and milk production in wk 4 of lactation; additionally, for multiparous cows, dry period length and previous lactation dry-off linear SCS were collected. Data were analyzed separately for primiparous and multiparous cows using backward stepwise elimination. To produce final mixed effects ANOVA models, primiparous cows (n = 201) were randomized to 35.8% (n = 72) OXY40, 32.8% (n = 66) OXY20, and 31.3% (n = 63) CNTR. Multiparous groups (n = 435) were randomized to 34.7% (n = 151) OXY40, 29.7% (n = 129) OXY20, and 35.6% (n = 155) CNTR. The median (range) colostrum yield was 6.0 (0-20.6) kg and [IgG] was 98.5 (0.1-293.6) g/L in the study population. In primiparous cows, OXY40 had a higher colostrum yield (LSM [95% CI]) of 5.4 (4.9-5.9) kg compared with both OXY20 (4.1 [3.5-4.7] kg) and CNTR (3.8 [3.3-4.3] kg). In multiparous cows, OXY40, OXY20, and CNTR did not differ in colostrum yield (5.9 [5.3-6.5], 5.7 [5.1-6.3], and 5.4 [4.8-6.0] kg, respectively), but colostrum yield was greater in parity 2 compared with all other parities, cows giving birth to male calves, cows with the highest milk production at wk 4 of lactation, and cows with a dry period of >65 d. Oxytocin use did not affect [IgG] in either primiparous or multiparous cows, but [IgG] was highest in cows in parity ≥4 and lowest in cows dry >65 d. In summary, oxytocin use at 40 IU i.m. was associated with a higher colostrum yield in primiparous cows only and no change in [IgG]. Oxytocin use likely addressed disturbed milk ejection and therefore increased colostrum yield in heifers milked for the first time in a rotary parlor. This study confirms cow characteristics associated with colostrum production within a single herd.
- Open Access
- 1 September 2024
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 107 (9) , 7337-7351
Effects of flow-responsive pulsation on teat tissue condition and milking performance in Holstein dairy cows
The objectives of this study were to assess the effect of a reduced liner-open phase applied through flow-responsive pulsation (FRP), as a method to provide supplemental stimulation, on teat tissue conditions and milking characteristics in dairy cows. In 2 switch-back trials, 156 Holstein cows milked 3 times daily were assigned to the FRP or conventional (CON) group in alternating sequences. Trial 1 lasted for 35 d and was split into 5 alternating 1-wk periods of FRP and CON. The duration of trial 2 was 84 d, consisting of 4 alternating 3-wk periods of FRP and CON. Premilking udder preparation for both groups consisted of predipping, forestripping, and wiping the teats. Upon milking unit attachment, the FRP cows were milked at a pulsation rate of 50 cycles/min and a pulsation ratio of 30:70 until the preset milk flow threshold of 0.5 kg/min was reached. When the threshold value of 0.5 kg/min was reached, the pulsation was automatically switched to milking mode, which consisted of a pulsation rate of 60 cycles/min and a pulsation ratio of 70:30. Cows in the CON group were milked by milking mode (pulsation rate, 60 cycles/min; pulsation ratio, 70:30) immediately after attachment of the milking unit. We assessed machine milking-induced short-term changes to the teat tissue by palpation and visual inspection during trial 1, and we assessed teat-end hyperkeratosis in trial 2. Electronic on-farm milk meters were used to assess milking characteristics: milk yield (kg/milking session), milking unit-on time (s), 2-min milk yield (kg), peak milk flow rate (kg/min), and duration of low milk flow rate (s). Generalized linear mixed models were used to analyze the effects of treatment on the outcome variables. The odds of machine milking-induced short-term changes to the teat tissue were lower for cows in the FRP group than for those in the CON group: odds ratio (95% CI) = 0.41 (0.31-0.55). There were no meaningful differences in the odds of teat-end hyperkeratosis between the FRP and CON groups: odds ratio (95% CI) = 1.05 (0.38-2.89). The LSM (95% CI) of milking characteristics in the FRP and CON groups were 14.3 (13.8-14.7) and 14.3 kg (13.8-14.7) for milk yield, respectively; 272 (264-281) and 270 s (262-278) for milking unit-on time, respectively; and 5.0 (4.8-5.1) and 4.9 kg/min (4.7-5.1) for peak milk flow rate, respectively. The FRP group had lower odds of bimodality than the CON group: odds ratio (95% CI) = 0.67 (0.61-0.74). In reference to CON, the odds ratios (95% CI) in FRP were 1.05 (0.76-1.46) for kick-off and 1.02 (0.85-1.23) for milking unit reattachment. In this study, cows that were milked using FRP had lower odds of postmilking short-term changes to the teat tissue and lower odds of bimodal milk flow. We conclude that FRP may foster adequate teat stimulation in cows before the initiation of milk harvest and has the potential to improve teat tissue conditions.
- 1 September 2024
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 107 (9) , 7337-7351
Open AccessEffects of flow-responsive pulsation on teat tissue condition and milking performance in Holstein dairy cows
The objectives of this study were to assess the effect of a reduced liner-open phase applied through flow-responsive pulsation (FRP), as a method to provide supplemental stimulation, on teat tissue conditions and milking characteristics in dairy cows. In 2 switch-back trials, 156 Holstein cows milked 3 times daily were assigned to the FRP or conventional (CON) group in alternating sequences. Trial 1 lasted for 35 d and was split into 5 alternating 1-wk periods of FRP and CON. The duration of trial 2 was 84 d, consisting of 4 alternating 3-wk periods of FRP and CON. Premilking udder preparation for both groups consisted of predipping, forestripping, and wiping the teats. Upon milking unit attachment, the FRP cows were milked at a pulsation rate of 50 cycles/min and a pulsation ratio of 30:70 until the preset milk flow threshold of 0.5 kg/min was reached. When the threshold value of 0.5 kg/min was reached, the pulsation was automatically switched to milking mode, which consisted of a pulsation rate of 60 cycles/min and a pulsation ratio of 70:30. Cows in the CON group were milked by milking mode (pulsation rate, 60 cycles/min; pulsation ratio, 70:30) immediately after attachment of the milking unit. We assessed machine milking-induced short-term changes to the teat tissue by palpation and visual inspection during trial 1, and we assessed teat-end hyperkeratosis in trial 2. Electronic on-farm milk meters were used to assess milking characteristics: milk yield (kg/milking session), milking unit-on time (s), 2-min milk yield (kg), peak milk flow rate (kg/min), and duration of low milk flow rate (s). Generalized linear mixed models were used to analyze the effects of treatment on the outcome variables. The odds of machine milking-induced short-term changes to the teat tissue were lower for cows in the FRP group than for those in the CON group: odds ratio (95% CI) = 0.41 (0.31-0.55). There were no meaningful differences in the odds of teat-end hyperkeratosis between the FRP and CON groups: odds ratio (95% CI) = 1.05 (0.38-2.89). The LSM (95% CI) of milking characteristics in the FRP and CON groups were 14.3 (13.8-14.7) and 14.3 kg (13.8-14.7) for milk yield, respectively; 272 (264-281) and 270 s (262-278) for milking unit-on time, respectively; and 5.0 (4.8-5.1) and 4.9 kg/min (4.7-5.1) for peak milk flow rate, respectively. The FRP group had lower odds of bimodality than the CON group: odds ratio (95% CI) = 0.67 (0.61-0.74). In reference to CON, the odds ratios (95% CI) in FRP were 1.05 (0.76-1.46) for kick-off and 1.02 (0.85-1.23) for milking unit reattachment. In this study, cows that were milked using FRP had lower odds of postmilking short-term changes to the teat tissue and lower odds of bimodal milk flow. We conclude that FRP may foster adequate teat stimulation in cows before the initiation of milk harvest and has the potential to improve teat tissue conditions.
- Open Access
- 1 August 2024
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 107 (8) , 6278-6287
The association between teat shape and bimodal milk ejection in Holstein dairy cows
Our objectives were to investigate the association of teat shape with (1) bimodality (2) incremental milk flow rates (average flow rates during the first 15 s, 15-30 s, 30-60 s, and 60-120 s of milking), and (3) peak milk flow rate in Holstein dairy cows milked 3 times per day. In this prospective cohort study, we analyzed 220,928 milking observations that were collected from 2,520 cows from a single dairy herd over a period of 31 d. Teat shape was visually assessed and classified into 1 of 4 categories as follows: (1) triangular barrel and pointed teat end (TP), (2) square barrel and round teat end (SR), (3) square barrel, round teat end, and flat in the area of the teat orifice (SRF), and (4) square barrel and flat teat end (SF). Individual cow-level milk flow rates were obtained using electronic on-farm milk meters. We considered bimodality to be present if any of the incremental milk flow rates (flow rates during 15-30 s, 30-60 s, or 60-120 s) were lower than any of the previous rates (flow rates during the first 15 s, 15-30 s, or 30-60 s). The frequency distribution of cows with different teat shapes was as follows: TP, 96 (3.8%); SR, 1,751 (69.5%); SRF, 617 (24.5%); and SF, 56 (2.2%). A generalized linear mixed model revealed differences in the odds of bimodality among cows with different teat shapes. Compared with cows in category SR, the odds (95% confidence interval) of bimodality of cows in other categories were as follows: TP, 0.68 (0.48-0.97); SF, 1.96 (1.21-3.19); and SRF, 1.46 (1.23-1.72). General linear mixed models indicated an association between teat shape and all incremental milk flow rates, with higher milk flow rates being present for cows with teat shapes in the SRF and SF categories. The general linear mixed model for the dependent variable peak milk flow rate indicated an association between teat shape and peak milk flow rate. Least squares means and 95% confidence intervals were 5.1 (4.9-5.3) kg/min for TP, 5.8 (5.5-6.1) kg/min for SF, 5.6 (5.5-5.7) for SRF, and 5.3 (5.3-5.4) for SR, respectively. We conclude that in this study cohort, bimodality is more likely to occur in cows with flat teat ends compared with those with a round teat ends. We attribute this relationship to the difference in milking speed across cows with different teat shapes. Teat shape may serve as a useful phenotype to identify cows that are more likely to exhibit bimodality. Because our study population was unique, future studies considering different circumstances such as breed, milking system, and milking routine are needed before results can be extrapolated.
- 1 August 2024
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 107 (8) , 6278-6287
Open AccessThe association between teat shape and bimodal milk ejection in Holstein dairy cows
Our objectives were to investigate the association of teat shape with (1) bimodality (2) incremental milk flow rates (average flow rates during the first 15 s, 15-30 s, 30-60 s, and 60-120 s of milking), and (3) peak milk flow rate in Holstein dairy cows milked 3 times per day. In this prospective cohort study, we analyzed 220,928 milking observations that were collected from 2,520 cows from a single dairy herd over a period of 31 d. Teat shape was visually assessed and classified into 1 of 4 categories as follows: (1) triangular barrel and pointed teat end (TP), (2) square barrel and round teat end (SR), (3) square barrel, round teat end, and flat in the area of the teat orifice (SRF), and (4) square barrel and flat teat end (SF). Individual cow-level milk flow rates were obtained using electronic on-farm milk meters. We considered bimodality to be present if any of the incremental milk flow rates (flow rates during 15-30 s, 30-60 s, or 60-120 s) were lower than any of the previous rates (flow rates during the first 15 s, 15-30 s, or 30-60 s). The frequency distribution of cows with different teat shapes was as follows: TP, 96 (3.8%); SR, 1,751 (69.5%); SRF, 617 (24.5%); and SF, 56 (2.2%). A generalized linear mixed model revealed differences in the odds of bimodality among cows with different teat shapes. Compared with cows in category SR, the odds (95% confidence interval) of bimodality of cows in other categories were as follows: TP, 0.68 (0.48-0.97); SF, 1.96 (1.21-3.19); and SRF, 1.46 (1.23-1.72). General linear mixed models indicated an association between teat shape and all incremental milk flow rates, with higher milk flow rates being present for cows with teat shapes in the SRF and SF categories. The general linear mixed model for the dependent variable peak milk flow rate indicated an association between teat shape and peak milk flow rate. Least squares means and 95% confidence intervals were 5.1 (4.9-5.3) kg/min for TP, 5.8 (5.5-6.1) kg/min for SF, 5.6 (5.5-5.7) for SRF, and 5.3 (5.3-5.4) for SR, respectively. We conclude that in this study cohort, bimodality is more likely to occur in cows with flat teat ends compared with those with a round teat ends. We attribute this relationship to the difference in milking speed across cows with different teat shapes. Teat shape may serve as a useful phenotype to identify cows that are more likely to exhibit bimodality. Because our study population was unique, future studies considering different circumstances such as breed, milking system, and milking routine are needed before results can be extrapolated.
- Open Access
The Association of Delayed Milk Ejection with Milking Performance in Holstein Cows in a Large Dairy Herd with Suboptimal Premilking Teat Stimulation
The primary objective was to investigate the association between delayed milk ejection (DME) and the average milk flow rate, milking unit-on time, and duration in a low milk flow rate in Holstein dairy cows in a large dairy herd with suboptimal premilking teat stimulation. Our second objective was to study the association between peak lactation milk yield and the occurrence of DME. This longitudinal field study was conducted at a 4300-cow dairy farm with a thrice-daily milking schedule over a 1-week period. We analyzed data from 61,677 cow milking observations from 2937 cows. Delayed milk ejection was defined as present if the 30–60 s milk flow rate was ≤3.1 kg/min. The mean average milk flow rate (MAMF, kg/min), mean milking unit-on time (MMUT, s), and mean duration of a low milk flow rate (MLMF, s) were calculated as the mean values from the 21 milking observations. General linear multivariable models revealed associations of DME with MAMF, MMUT, and MLMF. A multivariable ordinal logistic regression model revealed an association between peak lactation milk yield and DME. Cows with lower peak lactation milk yield had greater odds of exhibiting a higher frequency level of DME. The observed associations between DME and milking performance indices suggest that DME can negatively affect milking and parlor efficiency. Peak lactation milk yield may serve as a proxy to estimate cows’ risk of recurrent DME. Future research is warranted to test if alleviating DME through, for example, a modified milking routine influences the milking performance indices described herein.
Open AccessThe Association of Delayed Milk Ejection with Milking Performance in Holstein Cows in a Large Dairy Herd with Suboptimal Premilking Teat Stimulation
The primary objective was to investigate the association between delayed milk ejection (DME) and the average milk flow rate, milking unit-on time, and duration in a low milk flow rate in Holstein dairy cows in a large dairy herd with suboptimal premilking teat stimulation. Our second objective was to study the association between peak lactation milk yield and the occurrence of DME. This longitudinal field study was conducted at a 4300-cow dairy farm with a thrice-daily milking schedule over a 1-week period. We analyzed data from 61,677 cow milking observations from 2937 cows. Delayed milk ejection was defined as present if the 30–60 s milk flow rate was ≤3.1 kg/min. The mean average milk flow rate (MAMF, kg/min), mean milking unit-on time (MMUT, s), and mean duration of a low milk flow rate (MLMF, s) were calculated as the mean values from the 21 milking observations. General linear multivariable models revealed associations of DME with MAMF, MMUT, and MLMF. A multivariable ordinal logistic regression model revealed an association between peak lactation milk yield and DME. Cows with lower peak lactation milk yield had greater odds of exhibiting a higher frequency level of DME. The observed associations between DME and milking performance indices suggest that DME can negatively affect milking and parlor efficiency. Peak lactation milk yield may serve as a proxy to estimate cows’ risk of recurrent DME. Future research is warranted to test if alleviating DME through, for example, a modified milking routine influences the milking performance indices described herein.
- Open Access
Comparison of Sensor-Based and Audible Detection of Milking Liner Slips during Machine Milking of Dairy Cows
On-farm milk flow meter technology facilitates real-time assessment of individual cow milking observations and could be used to detect milking liner slips during machine milking of dairy cows. Here, we compared the accuracy of on-farm milk flow meters for detecting milking liner slips with that of audible detection and that of a portable vacuum recording system. Compared to audible detection methods, the on-farm milk flow meter facilitated the detection of milking liner slips with moderate accuracy. Using the vacuum recording system as the gold standard, the milk flow meter system failed to detect most of the liner slips, leading to poor agreement between the two devices. We conclude that the on-farm milk flow meter system tested here compared well with audible detection; however, when vacuum recordings were considered, we found significant levels of under-detection. Taken together, dairy operators may use the on-farm milk flow meter system to inform adjustments of the milking machine settings and monitor milking routine performance. However, the system is not suitable for monitoring short-duration vacuum fluctuations. Future research is warranted to optimize the sensor-based detection of milking liner slips.
Open AccessComparison of Sensor-Based and Audible Detection of Milking Liner Slips during Machine Milking of Dairy Cows
On-farm milk flow meter technology facilitates real-time assessment of individual cow milking observations and could be used to detect milking liner slips during machine milking of dairy cows. Here, we compared the accuracy of on-farm milk flow meters for detecting milking liner slips with that of audible detection and that of a portable vacuum recording system. Compared to audible detection methods, the on-farm milk flow meter facilitated the detection of milking liner slips with moderate accuracy. Using the vacuum recording system as the gold standard, the milk flow meter system failed to detect most of the liner slips, leading to poor agreement between the two devices. We conclude that the on-farm milk flow meter system tested here compared well with audible detection; however, when vacuum recordings were considered, we found significant levels of under-detection. Taken together, dairy operators may use the on-farm milk flow meter system to inform adjustments of the milking machine settings and monitor milking routine performance. However, the system is not suitable for monitoring short-duration vacuum fluctuations. Future research is warranted to optimize the sensor-based detection of milking liner slips.