Moritz Ruhwedel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Moritz Ruhwedel has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Florian Sutter
German Aerospace Center
2 shared publications - Peter Heller
Institute of Solar Research Deutsches Zentrum für Luft‐ und Raumfahrt e. V. Köln Germany
2 shared publications - Robert Pitz-Paal
Institute of Solar Research, German Aerospace Center, Cologne, Germany
2 shared publications - Eckhard Lüpfert
Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) image/svg+xml
1 shared publication - Kai Gehrke
Deutsches Zentrum für Luft- und Raumfahrt (DLR), Institut für Vernetzte Energiesysteme 1 , Carl-von-Ossietzky-Straße 15, Oldenburg 26129
1 shared publication - Stephan J. Heise
Institute of Solar Research Deutsches Zentrum für Luft‐ und Raumfahrt e. V. Köln Germany
1 shared publication
Latest Publications
- Open Access
- 26 November 2025
- Published by Wiley in Physica Status Solidi (a)
- Vol. 222 (24)
Setup for Long‐Term Outdoor Testing of Optically Modified PV Modules Regarding their Thermal and Electrical Behavior Under Load
Optical modifications of the light‐facing side of photovoltaic (PV) modules can be used to increase their efficiency by implementing anti‐reflective or anti‐soiling properties or by achieving a reduction of the operating temperature. Furthermore, such front‐optical modifications can be utilized to hybridize concentrating solar thermal systems and PV systems. In order to characterize such modifications correctly, special attention has to be paid to two points: the modules have to be operated under load to keep the cells at a realistic operating temperature, and high precision of the temperature measurement is required to quantify the potentially very small effects of the modifications (e.g., for radiative cooling decreases in operating temperature of less than 1 K have to be expected). In this paper, a setup is presented for testing front‐optical modifications in fixed tilt configuration in Almería, Spain. The loading is achieved by the use of an electronic load and the precision of the temperature measurement is achieved by Platinum resistance temperature detectors (Pt100s) laminated into the modules in combination with high precision multimeters. To demonstrate the capabilities of the setup, exemplary measurement data is shown.
- 26 November 2025
- Published by Wiley in Physica Status Solidi (a)
- Vol. 222 (24)
Open AccessSetup for Long‐Term Outdoor Testing of Optically Modified PV Modules Regarding their Thermal and Electrical Behavior Under Load
Optical modifications of the light‐facing side of photovoltaic (PV) modules can be used to increase their efficiency by implementing anti‐reflective or anti‐soiling properties or by achieving a reduction of the operating temperature. Furthermore, such front‐optical modifications can be utilized to hybridize concentrating solar thermal systems and PV systems. In order to characterize such modifications correctly, special attention has to be paid to two points: the modules have to be operated under load to keep the cells at a realistic operating temperature, and high precision of the temperature measurement is required to quantify the potentially very small effects of the modifications (e.g., for radiative cooling decreases in operating temperature of less than 1 K have to be expected). In this paper, a setup is presented for testing front‐optical modifications in fixed tilt configuration in Almería, Spain. The loading is achieved by the use of an electronic load and the precision of the temperature measurement is achieved by Platinum resistance temperature detectors (Pt100s) laminated into the modules in combination with high precision multimeters. To demonstrate the capabilities of the setup, exemplary measurement data is shown.
- Open Access
- 13 February 2024
- Published by Wiley in Energy Technology
- Vol. 12 (5)
Integrated Concentrating Solar/Photovoltaic Hybrid Concepts—Technological Discussion, Energy Yield, and Cost Considerations
Concentrating solar thermal (CST) technologies are a sustainable way to produce high‐temperature heat. Four concepts of integrating photovoltaics (PV) into CST plants, namely Rear‐PV, PV‐Mirror, bifacial PV‐Mirror and Spillage‐concentrating PV (CPV), are compared and the technological and economic outcome is discussed. The concepts are presented for the use with solar tower systems, but can also be applied to other configurations. In this work, parameters for each concept to quantify annual energy production and investment costs are derived. It is determined that implementing Rear‐PV, PV‐Mirror, bifacial PV‐Mirror, and Spillage‐CPV in a concentrating solar power tower plant leads to an additional energy yield as high as 23%, 29%, 40%, and 36%, respectively, on the same mirror aperture size. For the concepts of the Rear‐PV, PV‐Mirror, and bifacial PV‐Mirror, maximum allowable cost per aperture area can be 3.0, 4.8, and 5.7 times the cost of conventional mirrors, to reach a break‐even of the specific investment cost per annually produced energy. Such values are considered to be achievable for PV‐Mirror and bifacial PV‐Mirror, but not for Rear‐PV. For Spillage‐CPV, a break‐even of investment cost can be achieved if installed in areas with spillage radiation flux exceeding ≈350 kWm−2at peak.
- 13 February 2024
- Published by Wiley in Energy Technology
- Vol. 12 (5)
Open AccessIntegrated Concentrating Solar/Photovoltaic Hybrid Concepts—Technological Discussion, Energy Yield, and Cost Considerations
Concentrating solar thermal (CST) technologies are a sustainable way to produce high‐temperature heat. Four concepts of integrating photovoltaics (PV) into CST plants, namely Rear‐PV, PV‐Mirror, bifacial PV‐Mirror and Spillage‐concentrating PV (CPV), are compared and the technological and economic outcome is discussed. The concepts are presented for the use with solar tower systems, but can also be applied to other configurations. In this work, parameters for each concept to quantify annual energy production and investment costs are derived. It is determined that implementing Rear‐PV, PV‐Mirror, bifacial PV‐Mirror, and Spillage‐CPV in a concentrating solar power tower plant leads to an additional energy yield as high as 23%, 29%, 40%, and 36%, respectively, on the same mirror aperture size. For the concepts of the Rear‐PV, PV‐Mirror, and bifacial PV‐Mirror, maximum allowable cost per aperture area can be 3.0, 4.8, and 5.7 times the cost of conventional mirrors, to reach a break‐even of the specific investment cost per annually produced energy. Such values are considered to be achievable for PV‐Mirror and bifacial PV‐Mirror, but not for Rear‐PV. For Spillage‐CPV, a break‐even of investment cost can be achieved if installed in areas with spillage radiation flux exceeding ≈350 kWm−2at peak.