Jessica Silvestre Vanni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jessica Silvestre Vanni has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Claudio Antônio Perottoni
Universidade de Caxias do Sul, Caxias do Sul - RS, 95070-560, Brazil
2 shared publications - Eduardo Thomazi
Federal Institute of Education, Science and Technology of Rio Grande do Sul (IFRS), Campus Caxias do Sul, Caxias do Sul, Brazil
2 shared publications - Janete Eunice Zorzi
Universidade de Caxias do Sul, Caxias do Sul, Brazil
2 shared publications - Thiago de Oliveira Gamba
School of Dentistry Federal University of Rio Grande do Sul, UFRGS Porto Alegre Brazil
2 shared publications - Celso Roman Junior
Post Graduate Program in Engineering of Processes and Technologies (PGEPROTEC), University of Caxias do Sul (UCS) Caxias do Sul Rio Grande do Sul Brazil
1 shared publication
Latest Publications
- 23 May 2024
- Published by Wiley in International Journal of Paediatric Dentistry
- Vol. 35 (1) , 129-135
Determination of relative dose of ionizing radiation in the thyroid gland using a panoramic device with different protocols
Background: The use of panoramic radiography (PR) is a complementary examination to aid in the diagnosis of cases in paediatric dentistry. The lack of specific protocols for these devices, however, can result in high doses of radiation, affecting critical organs such as the thyroid.Aim: To evaluate the discrepancies in ionizing radiation received by the thyroid during PR examinations using anthropomorphic paediatric simulators built from computed tomography images.Design: Two anthropomorphic paediatric phantoms were printed and used, representing children aged 6 and 11 years, with an opening in the thyroid region for the insertion of dosimetric radiographic films. The simulators were subjected to different pre‐existing protocols in the PR devices. The radiographic films were processed and analysed using a luxmeter.Results: The radiation dose to the thyroid was higher in the 6‐year‐old phantom than in the 11‐year‐old phantom, for given exposure factors. In addition, there was an increase in dose in children's protocols compared with small adult protocols.Conclusion: Therefore, companies that develop PR equipment must develop child protocols for separate age groups that will consequently reduce the radiation dose in children, especially in their critical organs.
- 23 May 2024
- Published by Wiley in International Journal of Paediatric Dentistry
- Vol. 35 (1) , 129-135
Determination of relative dose of ionizing radiation in the thyroid gland using a panoramic device with different protocols
Background: The use of panoramic radiography (PR) is a complementary examination to aid in the diagnosis of cases in paediatric dentistry. The lack of specific protocols for these devices, however, can result in high doses of radiation, affecting critical organs such as the thyroid.Aim: To evaluate the discrepancies in ionizing radiation received by the thyroid during PR examinations using anthropomorphic paediatric simulators built from computed tomography images.Design: Two anthropomorphic paediatric phantoms were printed and used, representing children aged 6 and 11 years, with an opening in the thyroid region for the insertion of dosimetric radiographic films. The simulators were subjected to different pre‐existing protocols in the PR devices. The radiographic films were processed and analysed using a luxmeter.Results: The radiation dose to the thyroid was higher in the 6‐year‐old phantom than in the 11‐year‐old phantom, for given exposure factors. In addition, there was an increase in dose in children's protocols compared with small adult protocols.Conclusion: Therefore, companies that develop PR equipment must develop child protocols for separate age groups that will consequently reduce the radiation dose in children, especially in their critical organs.
- 14 February 2024
- Published by Wiley in Polymer Composites
- Vol. 45 (7) , 6720-6732
Acrylonitrile‐butadiene‐styrene‐based composites for the manufacture of anthropomorphic simulators
The development of functional compounds for extrusion applied in the additive manufacturing of anthropomorphic simulators is interesting, as it guarantees the manufacture of a 3D model similar to the patient. These simulators find applications in therapies or laboratory tests involving x‐rays. In order to replicate human conditions in these tests, it is essential to create materials that closely match the properties of human tissue, including the smoothness of soft tissues and the hardness of the bone tissue. This study developed ceramic‐polymeric composites, where the tomography intensity of each mixture was measured experimentally. Combinations of acrylonitrile butadiene styrene (ABS) with zirconium oxide and basic bismuth carbonate allowed imitation of bone tissue. The samples containing zirconium oxide and basic bismuth carbonate presented results that exceeded the minimum limit and reached a value close to 2000 Hounsfield units (HU) with 12% basic bismuth carbonate content. Combinations of ABS with hydroxyapatite and aluminum oxide can imitate soft tissues. The use of a surfactant facilitated the mixing of ceramic filler with polymer. Finally, 3D printing of a physical model was performed using a dual extruder printer, allowing simultaneous printing of bone and soft tissue components.Highlights: Material mimicking x‐ray attenuation similar to bone tissue. Relation between 3D printing porosity and intensity in Hounsfield unit. Computed tomography tests on a 3D printed anthropomorphic phantom. Creating a 3D model from a Computed Tomography scan. Double extruder for 3D printing of two tissue simultaneously.
- 14 February 2024
- Published by Wiley in Polymer Composites
- Vol. 45 (7) , 6720-6732
Acrylonitrile‐butadiene‐styrene‐based composites for the manufacture of anthropomorphic simulators
The development of functional compounds for extrusion applied in the additive manufacturing of anthropomorphic simulators is interesting, as it guarantees the manufacture of a 3D model similar to the patient. These simulators find applications in therapies or laboratory tests involving x‐rays. In order to replicate human conditions in these tests, it is essential to create materials that closely match the properties of human tissue, including the smoothness of soft tissues and the hardness of the bone tissue. This study developed ceramic‐polymeric composites, where the tomography intensity of each mixture was measured experimentally. Combinations of acrylonitrile butadiene styrene (ABS) with zirconium oxide and basic bismuth carbonate allowed imitation of bone tissue. The samples containing zirconium oxide and basic bismuth carbonate presented results that exceeded the minimum limit and reached a value close to 2000 Hounsfield units (HU) with 12% basic bismuth carbonate content. Combinations of ABS with hydroxyapatite and aluminum oxide can imitate soft tissues. The use of a surfactant facilitated the mixing of ceramic filler with polymer. Finally, 3D printing of a physical model was performed using a dual extruder printer, allowing simultaneous printing of bone and soft tissue components.Highlights: Material mimicking x‐ray attenuation similar to bone tissue. Relation between 3D printing porosity and intensity in Hounsfield unit. Computed tomography tests on a 3D printed anthropomorphic phantom. Creating a 3D model from a Computed Tomography scan. Double extruder for 3D printing of two tissue simultaneously.