A. M. Belov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
A. M. Belov has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
A. V. Sushkov
National Research Centre “Kurchatov Institute”, Moscow, Russia
2 shared publicationsA. V. Stepin
National Research Centre “Kurchatov Institute”, Moscow, Russia
1 shared publicationA. Yu. Balashov
National Research Centre “Kurchatov Institute”, Moscow, Russia
1 shared publication- Baurzhan Chektybayev
Institute of Atomic Energy, National Nuclear Center of the Republic of Kazakhstan, Kurchatov, Kazakhstan
1 shared publication - D. S. Sergeev
National Research Center Kurchatov Institute, Moscow, Russia
1 shared publication - D. V. Ryzhakov
National Research Center Kurchatov Institute, Moscow, Russia
1 shared publication
Latest Publications
- 1 April 2025
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 51 (4) , 397-413
Methods for Processing Signals of Magnetic Probes at the T-15MD Tokamak
The applicability of several methods for processing experimental signals of local magnetic probes is analyzed for the purpose of determining the poloidal mode number m of MHD perturbations in plasma of tokamak with noncircular cross-section. These methods are the two-dimensional Fourier transform, the -Hilbert transform method, the method of singular value decomposition, and the method of phase matrices. The methods listed were applied under conditions of the D-shaped cross-section of the T-15MD tokamak vacuum vessel. They showed good results in determining the poloidal wave numbers of MHD perturbations for both synthetic and experimental signals of local magnetic probes. The results of processing the experimental data from local magnetic probes were in good agreement with the data of soft X-ray diagnostics of the T‑15MD tokamak.
- 1 April 2025
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 51 (4) , 397-413
Methods for Processing Signals of Magnetic Probes at the T-15MD Tokamak
The applicability of several methods for processing experimental signals of local magnetic probes is analyzed for the purpose of determining the poloidal mode number m of MHD perturbations in plasma of tokamak with noncircular cross-section. These methods are the two-dimensional Fourier transform, the -Hilbert transform method, the method of singular value decomposition, and the method of phase matrices. The methods listed were applied under conditions of the D-shaped cross-section of the T-15MD tokamak vacuum vessel. They showed good results in determining the poloidal wave numbers of MHD perturbations for both synthetic and experimental signals of local magnetic probes. The results of processing the experimental data from local magnetic probes were in good agreement with the data of soft X-ray diagnostics of the T‑15MD tokamak.
- 1 April 2024
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 50 (4) , 457-469
Simulations of TRT Vacuum Vessel Effect on the Magnetic Diagnostics System Sensor Signals
The results of model numerical calculations are presented, showing the effect of the TRT vacuum vessel on the amplitudes and phases of the magnetic sensors signals, which are located on the inner and outer vacuum vessel surfaces. It is shown that the characteristic times of loop voltage sensors considerably depend on their position on the TRT vacuum vessel. Therefore, their accurate mutual matching is required, especially in the dynamic stage of the discharge, when high eddy currents are induced in the vacuum vessel. The results of numerical calculations for the case of periodic disturbances in the plasma column are presented. They showed that the vacuum vessel almost completely shields the signals of the magnetic sensors located on the outer surface of the vacuum vessel. Moreover, it affects not only the amplitudes of magnetic sensors signals, but also their phases. Numerical studies brought us to conclusion that it is of priority to install the magnetic sensors just on the inner surface of the TRT vacuum vessel.
- 1 April 2024
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 50 (4) , 457-469
Simulations of TRT Vacuum Vessel Effect on the Magnetic Diagnostics System Sensor Signals
The results of model numerical calculations are presented, showing the effect of the TRT vacuum vessel on the amplitudes and phases of the magnetic sensors signals, which are located on the inner and outer vacuum vessel surfaces. It is shown that the characteristic times of loop voltage sensors considerably depend on their position on the TRT vacuum vessel. Therefore, their accurate mutual matching is required, especially in the dynamic stage of the discharge, when high eddy currents are induced in the vacuum vessel. The results of numerical calculations for the case of periodic disturbances in the plasma column are presented. They showed that the vacuum vessel almost completely shields the signals of the magnetic sensors located on the outer surface of the vacuum vessel. Moreover, it affects not only the amplitudes of magnetic sensors signals, but also their phases. Numerical studies brought us to conclusion that it is of priority to install the magnetic sensors just on the inner surface of the TRT vacuum vessel.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 86 (7) , 1663-1666
Comparison of Operating Parameters of the KTM Tokamak with Operating Ranges of the Facility
This article presents estimates of the operating region of the KTM tokamak in terms of plasma density and current for ohmic regimes on the basis of machine design parameters. The discharge parameters obtained in the experiments in 2021 are plotted on the diagram (ne, Ip). The increase in operating values of plasma current and achievement of boundary values of stability factor q ~ 4 are mentioned. It has been demonstrated that progressing into the region of higher plasma currents in the implemented density range leads to achievement of the limit in development of beams of accelerated electrons. Accordingly, the increase in operating plasma density is one of the aims of the next experimental campaign at the KTM tokamak.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 86 (7) , 1663-1666
Comparison of Operating Parameters of the KTM Tokamak with Operating Ranges of the Facility
This article presents estimates of the operating region of the KTM tokamak in terms of plasma density and current for ohmic regimes on the basis of machine design parameters. The discharge parameters obtained in the experiments in 2021 are plotted on the diagram (ne, Ip). The increase in operating values of plasma current and achievement of boundary values of stability factor q ~ 4 are mentioned. It has been demonstrated that progressing into the region of higher plasma currents in the implemented density range leads to achievement of the limit in development of beams of accelerated electrons. Accordingly, the increase in operating plasma density is one of the aims of the next experimental campaign at the KTM tokamak.