Comparison of Operating Parameters of the KTM Tokamak with Operating Ranges of the Facility
- 1 December 2023
- journal article
- research article
- Published by Pleiades Publishing Ltd in Physics of Atomic Nuclei
- Vol. 86 (7) , 1663-1666
Abstract
This article presents estimates of the operating region of the KTM tokamak in terms of plasma density and current for ohmic regimes on the basis of machine design parameters. The discharge parameters obtained in the experiments in 2021 are plotted on the diagram (ne, Ip). The increase in operating values of plasma current and achievement of boundary values of stability factor q ~ 4 are mentioned. It has been demonstrated that progressing into the region of higher plasma currents in the implemented density range leads to achievement of the limit in development of beams of accelerated electrons. Accordingly, the increase in operating plasma density is one of the aims of the next experimental campaign at the KTM tokamak.Keywords
This publication has 4 references indexed in Scilit:
- High performance plasma vertical position control system for upgraded MASTFusion Engineering and Design, 2013
- Li experiments on T-11M and T-10 in support of a steady-state tokamak concept with Li closed loop circulationNuclear Fusion, 2011
- KTM Experimental Complex Project StatusFusion Science and Technology, 2005
- Creation and control of variably shaped plasmas in TCVPlasma Physics and Controlled Fusion, 1994