Carolina Marto-Costa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Carolina Marto-Costa has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Ana Paula Serro
Centro de Química Estrutural (CQE), Chemical Engineering Department and Institute of Molecular Sciences, Instituto Superior Técnico, University of Lisbon, Av. Rovisco Pais 1, 1049-001 Lisbon, Portugal; Egas Moniz Centre for Interdisciplinary Research (CiiEM), Egas Moniz School of Health & Science, Campus Universitário, Quinta da Granja, 2829-511 Monte de Caparica, Almada, Portugal
4 shared publications - Ana Catarina Branco
CQE, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal; CDP2T, Escola Superior de Tecnologia de Setúbal, Instituto Politécnico de Setúbal, Setúbal, Portugal
2 shared publications - Andreia Sofia Oliveira
Centro de Química Estrutural (CQE), Institute of Molecular Sciences, Department of Chemical Engineering, Instituto Superior Técnico, University of Lisbon, Av. Rovisco Pais 1, 1049-001 Lisbon, Portugal
2 shared publications - Madalena Salema-Oom
Egas Moniz Centre for Interdisciplinary Research (CiiEM), Egas Moniz School of Health & Science, Campus Universitário, Quinta da Granja, 2829-511 Monte de Caparica, Almada, Portugal
2 shared publications - Rogerio Colaco
Instituto Superior Técnico, University of Lisbon, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
2 shared publications - Adelino Moura Galvão
Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1, 1049-001 Lisboa, Portugal
1 shared publication
Latest Publications
- Open Access
Free-Standing, Water-Resistant, and Conductivity-Enhanced PEDOT:PSS Films from In Situ Polymerization of 3-Hydroxymethyl-3-Methyl-Oxetane
Free-standing films based on conducting polymers, such as poly(3,4-ethylenedioxythiophene): poly(styrene sulfonate) (PEDOT:PSS), offer many benefits over traditional metal electrodes for applications in flexible electronics. However, to ensure structural integrity when contacting aqueous environments and high levels of electrical conductivity, solution-processed polymers require additives that act as crosslinking agents and conductivity enhancers. In this work, a new approach is presented to fabricate water-resistant free-standing films of PEDOT:PSS and simultaneously increase their conductivity, using an oxetane compound as an additive. It is shown that at moderate temperatures, oxetane polymerizes within the PEDOT:PSS acidic medium, forming hydroxymethyl-substituted polyether compounds that form a network upon crosslinking with PSS. The polymer composite films show self-sustainability, structural stability in aqueous environments, and enhanced conductivity. Finally, the potential of the free-standing films as health-monitoring electrodes, specifically for human electrocardiography, is explored.
Open AccessFree-Standing, Water-Resistant, and Conductivity-Enhanced PEDOT:PSS Films from In Situ Polymerization of 3-Hydroxymethyl-3-Methyl-Oxetane
Free-standing films based on conducting polymers, such as poly(3,4-ethylenedioxythiophene): poly(styrene sulfonate) (PEDOT:PSS), offer many benefits over traditional metal electrodes for applications in flexible electronics. However, to ensure structural integrity when contacting aqueous environments and high levels of electrical conductivity, solution-processed polymers require additives that act as crosslinking agents and conductivity enhancers. In this work, a new approach is presented to fabricate water-resistant free-standing films of PEDOT:PSS and simultaneously increase their conductivity, using an oxetane compound as an additive. It is shown that at moderate temperatures, oxetane polymerizes within the PEDOT:PSS acidic medium, forming hydroxymethyl-substituted polyether compounds that form a network upon crosslinking with PSS. The polymer composite films show self-sustainability, structural stability in aqueous environments, and enhanced conductivity. Finally, the potential of the free-standing films as health-monitoring electrodes, specifically for human electrocardiography, is explored.
- Open Access
Tribomechanical Properties of PVA/Nomex® Composite Hydrogels for Articular Cartilage Repair
Due to the increasing prevalence of articular cartilage diseases and limitations faced by current therapeutic methodologies, there is an unmet need for new materials to replace damaged cartilage. In this work, poly(vinyl alcohol) (PVA) hydrogels were reinforced with different amounts of Nomex® (known for its high mechanical toughness, flexibility, and resilience) and sterilized by gamma irradiation. Samples were studied concerning morphology, chemical structure, thermal behavior, water content, wettability, mechanical properties, and rheological and tribological behavior. Overall, it was found that the incorporation of aramid nanostructures improved the hydrogel’s mechanical performance, likely due to the reinforcement’s intrinsic strength and hydrogen bonding to PVA chains. Additionally, the sterilization of the materials also led to superior mechanical properties, possibly related to the increased crosslinking density through the hydrogen bonding caused by the irradiation. The water content, wettability, and tribological performance of PVA hydrogels were not compromised by either the reinforcement or the sterilization process. The best-performing composite, containing 1.5% wt. of Nomex®, did not induce cytotoxicity in human chondrocytes. Plugs of this hydrogel were inserted in porcine femoral heads and tested in an anatomical hip simulator. No significant changes were observed in the hydrogel or cartilage, demonstrating the material’s potential to be used in cartilage replacement.
Open AccessTribomechanical Properties of PVA/Nomex® Composite Hydrogels for Articular Cartilage Repair
Due to the increasing prevalence of articular cartilage diseases and limitations faced by current therapeutic methodologies, there is an unmet need for new materials to replace damaged cartilage. In this work, poly(vinyl alcohol) (PVA) hydrogels were reinforced with different amounts of Nomex® (known for its high mechanical toughness, flexibility, and resilience) and sterilized by gamma irradiation. Samples were studied concerning morphology, chemical structure, thermal behavior, water content, wettability, mechanical properties, and rheological and tribological behavior. Overall, it was found that the incorporation of aramid nanostructures improved the hydrogel’s mechanical performance, likely due to the reinforcement’s intrinsic strength and hydrogen bonding to PVA chains. Additionally, the sterilization of the materials also led to superior mechanical properties, possibly related to the increased crosslinking density through the hydrogen bonding caused by the irradiation. The water content, wettability, and tribological performance of PVA hydrogels were not compromised by either the reinforcement or the sterilization process. The best-performing composite, containing 1.5% wt. of Nomex®, did not induce cytotoxicity in human chondrocytes. Plugs of this hydrogel were inserted in porcine femoral heads and tested in an anatomical hip simulator. No significant changes were observed in the hydrogel or cartilage, demonstrating the material’s potential to be used in cartilage replacement.
- Open Access
- 29 January 2024
- Published by Elsevier in Carbohydrate Polymers
- Vol. 331, 121880
Improved triamcinolone acetonide-eluting contact lenses based on cyclodextrins and high hydrostatic pressure assisted complexation
- 29 January 2024
- Published by Elsevier in Carbohydrate Polymers
- Vol. 331, 121880
Open AccessImproved triamcinolone acetonide-eluting contact lenses based on cyclodextrins and high hydrostatic pressure assisted complexation
- 28 February 2022
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 110 (8) , 1839-1852
Development of polycarbonate urethane‐based materials with controlled diclofenac release for cartilage replacement
Hydrogels are very promising human cartilage replacement materials since they are able to mimic its structure and properties. Besides, they can be used as platforms for drug delivery to reduce inflammatory postsurgical reactions. Polycarbonate urethane (PCU) has been used in orthopedic applications due to its long‐term biocompatibility and bio‐durability. In this work, PCU‐based hydrogels with the ability to release an anti‐inflammatory (diclofenac) were developed, for the first time, for such purpose. The materials were reinforced with different amounts of cellulose acetate (CA, 10%, 15%, and 25% w/w) or carbon nanotubes (CNT, 1% and 2% w/w) in order to improve their mechanical properties. Samples were characterized in terms of compressive and tensile mechanical behavior. It was found that 15% CA and 2% CNT reinforcement led to the best mechanical properties. Thus, these materials were further characterized in terms of morphology, wettability, and friction coefficient (CoF). Contrarily to CNTs, the addition of CA significantly increased the material's porosity. Both materials became more hydrophilic, and the CoF slightly increased for PCU + 15%CA. The materials were loaded by soaking with diclofenac, and drug release experiments were conducted. PCU, PCU + 15%CA and PCU + 2%CNT presented similar release profiles, being able to ensure a controlled release of DFN for at least 4 days. Finally, in vitro cytotoxicity tests using human chondrocytes were also performed and confirmed a high biocompatibility for the three studied materials.
- 28 February 2022
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 110 (8) , 1839-1852
Development of polycarbonate urethane‐based materials with controlled diclofenac release for cartilage replacement
Hydrogels are very promising human cartilage replacement materials since they are able to mimic its structure and properties. Besides, they can be used as platforms for drug delivery to reduce inflammatory postsurgical reactions. Polycarbonate urethane (PCU) has been used in orthopedic applications due to its long‐term biocompatibility and bio‐durability. In this work, PCU‐based hydrogels with the ability to release an anti‐inflammatory (diclofenac) were developed, for the first time, for such purpose. The materials were reinforced with different amounts of cellulose acetate (CA, 10%, 15%, and 25% w/w) or carbon nanotubes (CNT, 1% and 2% w/w) in order to improve their mechanical properties. Samples were characterized in terms of compressive and tensile mechanical behavior. It was found that 15% CA and 2% CNT reinforcement led to the best mechanical properties. Thus, these materials were further characterized in terms of morphology, wettability, and friction coefficient (CoF). Contrarily to CNTs, the addition of CA significantly increased the material's porosity. Both materials became more hydrophilic, and the CoF slightly increased for PCU + 15%CA. The materials were loaded by soaking with diclofenac, and drug release experiments were conducted. PCU, PCU + 15%CA and PCU + 2%CNT presented similar release profiles, being able to ensure a controlled release of DFN for at least 4 days. Finally, in vitro cytotoxicity tests using human chondrocytes were also performed and confirmed a high biocompatibility for the three studied materials.