ACAlex Thomas Coyle

Alex Thomas Coyle

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alex Thomas Coyle has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Activation Energy of Conduction for Use in Temperature Corrections on Electrical Measurements of Concrete

    by Alex T. Coyle, Robert P. Spragg, Prannoy Suraneni, Armen N. Amirkhanian, Marisol Tsui-Chang, William Jason Weiss

    The formation factor obtained through electrical resistivity measurements is becoming a popular method to determine transport properties of concrete. Resistivity measurements are dependent on multiple factors, including degree of saturation, pore solution conductivity, and temperature. The Arrhenius equation is used to correct electrical resistivity for temperature effects using an activation energy of conduction (Ea-cond). This parameter has been measured on a wide variety of materials, including pore solutions, pastes, mortars, and concretes (with a variety of saturation states). The reported values of Ea-cond typically range from 9 to 39 kJ/mol. This article examines the factors affecting Ea-cond in order to select an appropriate temperature correction. In this study, Ea-cond was determined from data measured on various concrete mixtures used in transportation infrastructure applications as well as extracted and simulated pore solutions. The Ea-cond of pore solutions remains relatively constant (an average value of 13.9 ± 1.5 kJ/mol) for typical pore solutions and was slightly lower than the Ea-cond of saturated specimens (an average value of 15.8 kJ/mol). It was found that Ea-cond increases as the degree of saturation of the specimen is reduced. Drying increases the ionic concentration of the fluid in the pores; however, this does not explain the changes in Ea-cond. The effects of drying were determined to be primarily due to a change in the volume of the conductive fluid film in the concrete and in the connectivity of the fluid-filled pores. While it is better to directly measure the Ea-cond of a concrete mixture, this is not always feasible or practical. In such cases, for pore solutions, a value of 13.9 kJ/mol can be used, and for saturated concretes, a value of 15.8 kJ/mol can be used. For concretes with a varying degree of saturation, the Ea-cond can be estimated using the developed equation.


  • Prediction of Chloride Ingress in Saturated Concrete Using Formation Factor and Chloride Binding Isotherm

    by Chunyu Qiao, Alex Thomas Coyle, O. Burkan Isgor, W. Jason Weiss

    This article describes an approach to predict chloride ingress in saturated concrete using the formation factor and chloride binding isotherm. The formation factor is calculated as the ratio of the measured electrical resistivity of concrete and the electrical resistivity of the pore solution. The chloride binding isotherms are determined experimentally by placing ground concrete powder in sodium chloride (NaCl) solutions of varying concentrations and using titration to quantify the bound chloride contents. The Nernst-Plank equation is used to predict the chloride ingress with the ionic diffusion coefficients (calculated from the formation factor) and the fitted (Freundlich) chloride binding isotherm. The simulation results correspond well with experimentally obtained chloride profiles of saturated concrete after being ponded in NaCl solution. It is found that 70 % of simulated values for total chloride contents have a relative error of less than 30 % when compared to the experimental data. The approach presented in this article can be considered as an alternative for mixture qualification and quality control, though further work is needed to benchmark this against existing procedures.


  • Comparison of Linear Temperature Corrections and Activation Energy Temperature Corrections for Electrical Resistivity Measurements of Concrete

    by Alex T. Coyle, Robert P. Spragg, Prannoy Suraneni, Armen N. Amirkhanian, William J. Weiss

    Electrical resistivity measurements are increasingly being used as measurements for concrete acceptance in practice. It has been shown that these measurements are sensitive to temperature. This paper examines the influence of temperature on electrical resistivity measurements in concrete. Two temperature correction approaches that are commonly used by researchers and practitioners were evaluated: a linear temperature correction approach (α) and an activation energy–based temperature correction approach (Ea-cond). These approaches were compared with each other and their predictive capabilities were assessed using measured data from various concrete mixtures. It was found that for cases of low temperature sensitivity (low values of α or Ea-cond), the predictions obtained with α and with Ea-cond were similar. However, the Ea-cond approach was found to provide more accurate corrections (lower error) than corrections using α for measurements conducted at lower temperatures and for systems with higher temperature sensitivities (high values of α or Ea-cond). For saturated concrete specimens, both the linear (α) and activation energy (Ea-cond) approaches are acceptable, whereas the use of the Ea-cond approach provides better predictive capabilities in sealed concrete specimens, especially at low temperatures. The average values for Ea-cond were found to be 29.8 kJ/mol for sealed specimens and 15.8 kJ/mol for saturated specimens, and corresponding average values of α are 3.25 %/°C and 2.00 %/°C, respectively. The values for Ea-cond for saturated specimens are closer to what is expected of a pore solution on its own.