Xurui Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xurui Liu has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- Li Zhang
Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
11 shared publications - Chaoyu Yang
Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
4 shared publications - Hanchuan Tang
Huazhong University of Science and Technology
4 shared publications - Jianfeng Zang
Huazhong University of Science and Technology
4 shared publications - Bo Hao
Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
3 shared publications - Jiaxin Wang
Department of Urology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
3 shared publications
Latest Publications
- 13 November 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (46)
A fully hydrogel implantable patch for in situ ultrasonic monitoring of gastric leakage
Gastric leakage is a common and life-threatening postoperative complication, while delayed detection often leads to severe abdominal organ damage. Current radiological imaging modalities are limited in their ability to provide timely detection of gastric leakage, while the mechanical mismatch and long-term persistence of conventional electronic sensors limit their implantable applications. In this work, we developed a fully hydrogel-based ultrasonic metagel patch (USMP) for direct, real-time monitoring of gastric leakage via ultrasound imaging. The USMP incorporates a tree-ring air cell array, in which densely distributed air cells arranged in concentric rings create a strong back-scattering effect, thereby producing distinctive and stable ultrasound imaging signatures for rapid and sensitive detection. The air cells are encapsulated within biocompatible, hydrolytically degradable pH-responsive hydrogels, forming a fully hydrogel sensing architecture. The potential of the USMP for gastric leakage monitoring up to 7 days postimplantation is validated in the live rabbit model.
- 13 November 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (46)
A fully hydrogel implantable patch for in situ ultrasonic monitoring of gastric leakage
Gastric leakage is a common and life-threatening postoperative complication, while delayed detection often leads to severe abdominal organ damage. Current radiological imaging modalities are limited in their ability to provide timely detection of gastric leakage, while the mechanical mismatch and long-term persistence of conventional electronic sensors limit their implantable applications. In this work, we developed a fully hydrogel-based ultrasonic metagel patch (USMP) for direct, real-time monitoring of gastric leakage via ultrasound imaging. The USMP incorporates a tree-ring air cell array, in which densely distributed air cells arranged in concentric rings create a strong back-scattering effect, thereby producing distinctive and stable ultrasound imaging signatures for rapid and sensitive detection. The air cells are encapsulated within biocompatible, hydrolytically degradable pH-responsive hydrogels, forming a fully hydrogel sensing architecture. The potential of the USMP for gastric leakage monitoring up to 7 days postimplantation is validated in the live rabbit model.
- 2 October 2026
- Published by Springer Nature in Nature Reviews Materials
- p. 1-22
Engineering magnetic soft materials for biomedical applications
- 2 October 2026
- Published by Springer Nature in Nature Reviews Materials
- p. 1-22
Engineering magnetic soft materials for biomedical applications
- 23 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 11 (118)
AI-driven actuation-compatible tracking for closed-loop navigation of miniature robots in vivo
Miniature wireless magnetic robots (MWMRs) hold immense potential for minimally invasive interventions. Real-time tracking of MWMRs is essential for precise in vivo navigation but remains challenging. Tracking MWMRs via their emitted magnetic signals offers a viable solution, yet it has been limited to centimeter-scale robots because isolating weak MWMR signals from overwhelming actuation-induced interference becomes increasingly difficult with miniaturization. Here, we present an artificial intelligence (AI)–driven tracking system to overcome these challenges, enabling precise localization of millimeter-scale MWMRs in the presence of actuation fields. Our approach integrates a sensor array design with a transformer to accurately model and filter the interference, followed by a spatiotemporal transformer that interprets the extracted MWMR signals over a short time window to corresponding three-dimensional coordinates. Our system has been validated in a range of in vitro and in vivo experiments, demonstrating its applicability to closed-loop navigation of MWMRs in unshielded clinical settings.
- 23 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 11 (118)
AI-driven actuation-compatible tracking for closed-loop navigation of miniature robots in vivo
Miniature wireless magnetic robots (MWMRs) hold immense potential for minimally invasive interventions. Real-time tracking of MWMRs is essential for precise in vivo navigation but remains challenging. Tracking MWMRs via their emitted magnetic signals offers a viable solution, yet it has been limited to centimeter-scale robots because isolating weak MWMR signals from overwhelming actuation-induced interference becomes increasingly difficult with miniaturization. Here, we present an artificial intelligence (AI)–driven tracking system to overcome these challenges, enabling precise localization of millimeter-scale MWMRs in the presence of actuation fields. Our approach integrates a sensor array design with a transformer to accurately model and filter the interference, followed by a spatiotemporal transformer that interprets the extracted MWMR signals over a short time window to corresponding three-dimensional coordinates. Our system has been validated in a range of in vitro and in vivo experiments, demonstrating its applicability to closed-loop navigation of MWMRs in unshielded clinical settings.
- Top Cited PapersOpen Access
- 8 July 2026
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 123 (28)
Physically intelligent capsule robots with embodied memory and logic in the gastrointestinal tract
Miniaturized medical robots offer a promising solution for minimally invasive measurements and interventions in the gastrointestinal (GI) tract. Clinical assessment of GI disorders is commonly guided by threshold-based physiological indicators, including pressure, temperature, and pH, which motivate event-triggered strategies for personalized medicine. However, identifying homeostatic dysregulation and enabling in-situ therapy remains challenging, because ingestible robotic systems must tightly integrate sensing, decision-making, and actuation under severe constraints of size, power, and biosafety. Inspired by the autonomy of microorganisms that operate without neural processing, this work introduces physically intelligent capsule robots (PI Capbots) that enable homeostatic monitoring and targeted delivery within the GI tract, without relying on centralized electronic control. Through embodied stimuli-responsive memory and logic, PI Capbots effectively distill rich, detailed, and redundant physiological information into a small set of decoupled and event-triggered outputs suitable for operations in in vivo environments. In each PI Capbot, multistable metamaterials encode intraluminal pressure as mechanical memory, programmable hydrogels implement orthogonal sensing and logic operations, and helical fibers enable multimodal locomotion. Ex vivo and in vivo studies in large animal models demonstrate the efficacy, robustness, and reproducibility of PI Capbots, highlighting its potential for their translational medical applications.
- 8 July 2026
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 123 (28)
Top Cited PapersOpen AccessPhysically intelligent capsule robots with embodied memory and logic in the gastrointestinal tract
Miniaturized medical robots offer a promising solution for minimally invasive measurements and interventions in the gastrointestinal (GI) tract. Clinical assessment of GI disorders is commonly guided by threshold-based physiological indicators, including pressure, temperature, and pH, which motivate event-triggered strategies for personalized medicine. However, identifying homeostatic dysregulation and enabling in-situ therapy remains challenging, because ingestible robotic systems must tightly integrate sensing, decision-making, and actuation under severe constraints of size, power, and biosafety. Inspired by the autonomy of microorganisms that operate without neural processing, this work introduces physically intelligent capsule robots (PI Capbots) that enable homeostatic monitoring and targeted delivery within the GI tract, without relying on centralized electronic control. Through embodied stimuli-responsive memory and logic, PI Capbots effectively distill rich, detailed, and redundant physiological information into a small set of decoupled and event-triggered outputs suitable for operations in in vivo environments. In each PI Capbot, multistable metamaterials encode intraluminal pressure as mechanical memory, programmable hydrogels implement orthogonal sensing and logic operations, and helical fibers enable multimodal locomotion. Ex vivo and in vivo studies in large animal models demonstrate the efficacy, robustness, and reproducibility of PI Capbots, highlighting its potential for their translational medical applications.
- 17 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (106) , eadu4851
Miniature magneto-ultrasonic machines for wireless robotic sensing and manipulation
Intelligent miniature systems capable of wireless sensing and manipulation hold considerable promise for advancing biomedical applications. However, the development of these systems has been substantially hindered by sensing-actuation incompatibility at small scales. To overcome this challenge, we propose a robotic sensing approach that integrates embedded ultrasonic soft sensors (EUSSs) with magnetic actuators, resulting in a wireless sensor-integrated miniature machine with seamless integration and minimal interference between fields. The EUSS, with its compact dimensions (1.3 millimeters by 1.3 millimeters by 1.6 millimeters), softness (98 kilopascals), and lightweight design (4.6 milligrams), is compatible with both soft and rigid components in terms of deformability and size. By engineering onboard transducers and using passive ultrasound communication along with external magnetic fields, we could wirelessly detect and regulate environmental parameters such as force, vibration, viscosity, and temperature. Demonstrations in rabbit and porcine models show the potential for robotic feedback control, accurate drug dosing, and in situ physiological monitoring, paving the way for real-world applications of intelligent miniature machines.
- 17 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (106) , eadu4851
Miniature magneto-ultrasonic machines for wireless robotic sensing and manipulation
Intelligent miniature systems capable of wireless sensing and manipulation hold considerable promise for advancing biomedical applications. However, the development of these systems has been substantially hindered by sensing-actuation incompatibility at small scales. To overcome this challenge, we propose a robotic sensing approach that integrates embedded ultrasonic soft sensors (EUSSs) with magnetic actuators, resulting in a wireless sensor-integrated miniature machine with seamless integration and minimal interference between fields. The EUSS, with its compact dimensions (1.3 millimeters by 1.3 millimeters by 1.6 millimeters), softness (98 kilopascals), and lightweight design (4.6 milligrams), is compatible with both soft and rigid components in terms of deformability and size. By engineering onboard transducers and using passive ultrasound communication along with external magnetic fields, we could wirelessly detect and regulate environmental parameters such as force, vibration, viscosity, and temperature. Demonstrations in rabbit and porcine models show the potential for robotic feedback control, accurate drug dosing, and in situ physiological monitoring, paving the way for real-world applications of intelligent miniature machines.
- 25 June 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (103) , eadt0720
Photocatalytic microrobots for treating bacterial infections deep within sinuses
Microrobotic techniques are promising for treating biofilm infections located deep within the human body. However, the presence of highly viscous pus presents a formidable biological barrier, severely restricting targeted and minimally invasive treatments. In addition, conventional antibacterial agents exhibit limited payload integration with microrobotic systems, further compromising therapeutic efficiency. In this study, we propose a photocatalytic microrobot through a magnetically guided, optical fiber–assisted therapeutic platform specifically designed to treat bacterial infections in deep mucosal cavities. The microrobots comprising copper (Cu) single atom–doped bismuth oxoiodide (BiOI), termed CBMRs, can be guided and tracked by real-time x-ray imaging. Under external magnetic actuation, the illuminated region from the magnetically guided optical fiber synchronously follows the CBMR swarm, enabling effective antibacterial action at targeted infection sites. Upon continuous visible-light irradiation, the resultant photothermal effect substantially reduces the viscosity of pus on inflamed mucosal tissues, enhancing the penetration capability of the CBMR swarm by more than threefold compared with baseline conditions. Concurrently, atomic-level design of CBMRs facilitates robust generation of reactive oxygen species, enabling efficient biofilm disruption and reductions in bacterial viability. We validated the effectiveness of this integrated optical fiber–assisted microrobotic platform in a rabbit sinusitis model in vivo, demonstrating its potential for clinically relevant infection therapy.
- 25 June 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (103) , eadt0720
Photocatalytic microrobots for treating bacterial infections deep within sinuses
Microrobotic techniques are promising for treating biofilm infections located deep within the human body. However, the presence of highly viscous pus presents a formidable biological barrier, severely restricting targeted and minimally invasive treatments. In addition, conventional antibacterial agents exhibit limited payload integration with microrobotic systems, further compromising therapeutic efficiency. In this study, we propose a photocatalytic microrobot through a magnetically guided, optical fiber–assisted therapeutic platform specifically designed to treat bacterial infections in deep mucosal cavities. The microrobots comprising copper (Cu) single atom–doped bismuth oxoiodide (BiOI), termed CBMRs, can be guided and tracked by real-time x-ray imaging. Under external magnetic actuation, the illuminated region from the magnetically guided optical fiber synchronously follows the CBMR swarm, enabling effective antibacterial action at targeted infection sites. Upon continuous visible-light irradiation, the resultant photothermal effect substantially reduces the viscosity of pus on inflamed mucosal tissues, enhancing the penetration capability of the CBMR swarm by more than threefold compared with baseline conditions. Concurrently, atomic-level design of CBMRs facilitates robust generation of reactive oxygen species, enabling efficient biofilm disruption and reductions in bacterial viability. We validated the effectiveness of this integrated optical fiber–assisted microrobotic platform in a rabbit sinusitis model in vivo, demonstrating its potential for clinically relevant infection therapy.
- Top Cited PapersOpen Access
- 20 June 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (25) , eadv1682
A magnetically actuated microcatheter with soft rotatable tip for enhanced endovascular access and treatment efficiency
Endovascular interventions require fast access to affected regions, followed by effective treatment. Catheterizations are effective approaches for treating vascular diseases; however, they face challenges in accessibility, efficiency, and invasiveness in narrow, tortuous vascular systems. This study presents a submillimeter magnetically actuated soft rotatable-tipped microcatheter (MSRM) designed to access small blood vessels and provide efficient, minimally invasive therapeutic interventions for blood clot treatment. The MSRM’s rotatable tip design enhances accessibility and navigation speed through a rotation-assisted active steering strategy. Improved blood clot treatment efficiency is achieved through the MSRM’s multifunctionality: It can accelerate drug-blood clot interactions, mechanically break down blood clots, and retrieve clot debris. The low invasiveness is attributed to the soft material design and conservative actuation strategy. The performance of the MSRM is validated in both in vitro phantom studies and in vivo rabbit models, and the invasiveness is evaluated using a human placenta model.
- 20 June 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (25) , eadv1682
Top Cited PapersOpen AccessA magnetically actuated microcatheter with soft rotatable tip for enhanced endovascular access and treatment efficiency
Endovascular interventions require fast access to affected regions, followed by effective treatment. Catheterizations are effective approaches for treating vascular diseases; however, they face challenges in accessibility, efficiency, and invasiveness in narrow, tortuous vascular systems. This study presents a submillimeter magnetically actuated soft rotatable-tipped microcatheter (MSRM) designed to access small blood vessels and provide efficient, minimally invasive therapeutic interventions for blood clot treatment. The MSRM’s rotatable tip design enhances accessibility and navigation speed through a rotation-assisted active steering strategy. Improved blood clot treatment efficiency is achieved through the MSRM’s multifunctionality: It can accelerate drug-blood clot interactions, mechanically break down blood clots, and retrieve clot debris. The low invasiveness is attributed to the soft material design and conservative actuation strategy. The performance of the MSRM is validated in both in vitro phantom studies and in vivo rabbit models, and the invasiveness is evaluated using a human placenta model.
- Top Cited Papers
- 14 April 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 9 (8) , 1335-1348
An implantable hydrogel-based phononic crystal for continuous and wireless monitoring of internal tissue strains
Conventional implantable electronic sensors for continuous monitoring of internal tissue strains are yet to match the biomechanics of tissues while maintaining biodegradability, biocompatibility and wireless monitoring capability. Here we present a two-dimensional phononic crystal composed of periodic air columns in soft hydrogel, which was named ultrasonic metagel, and we demonstrate its use as implantable sensor for continuous and wireless monitoring of internal tissue strains. The metagel’s deformation shifts its ultrasonic bandgap, which can be wirelessly detected by an external ultrasonic probe. We demonstrate ex vivo the ability of the metagel sensor for monitoring tissue strains on porcine tendon, wounded tissue and heart. In live pigs, we further demonstrate the ability of the metagel to monitor tendon stretching, respiration and heartbeat, working stably during 30 days of implantation, and we loaded the metagel with growth factors to achieve different healing rates in subcutaneous wounds. The metagel results almost completely degraded 12 weeks after implantation. Our finding highlights the clinical potential of the ultrasonic sensor for tendon rehabilitation monitoring and drug delivery efficacy evaluation.
- 14 April 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 9 (8) , 1335-1348
Top Cited PapersAn implantable hydrogel-based phononic crystal for continuous and wireless monitoring of internal tissue strains
Conventional implantable electronic sensors for continuous monitoring of internal tissue strains are yet to match the biomechanics of tissues while maintaining biodegradability, biocompatibility and wireless monitoring capability. Here we present a two-dimensional phononic crystal composed of periodic air columns in soft hydrogel, which was named ultrasonic metagel, and we demonstrate its use as implantable sensor for continuous and wireless monitoring of internal tissue strains. The metagel’s deformation shifts its ultrasonic bandgap, which can be wirelessly detected by an external ultrasonic probe. We demonstrate ex vivo the ability of the metagel sensor for monitoring tissue strains on porcine tendon, wounded tissue and heart. In live pigs, we further demonstrate the ability of the metagel to monitor tendon stretching, respiration and heartbeat, working stably during 30 days of implantation, and we loaded the metagel with growth factors to achieve different healing rates in subcutaneous wounds. The metagel results almost completely degraded 12 weeks after implantation. Our finding highlights the clinical potential of the ultrasonic sensor for tendon rehabilitation monitoring and drug delivery efficacy evaluation.
- Open Access
- 28 March 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-10
Beyond surface tension-dominated water surface jumping
Water surface jumping motions of semi-aquatic insects are primarily rely on surface tension-dominated jumping mechanism to achieve impressive jumping performance. However, this mechanism faces an inherent physical constraint: the propulsion force must remain below the threshold required to break the water surface, limiting efficient momentum acquisition. Herein, we present a water surface jumping strategy that addresses the limitations of surface tension-dominated mechanism. Our approach allows the engineered jumper to achieve a record-breaking jumping height of 18 body lengths (63 cm) and take-off velocity of 100.6 body length/s (3.52 m/s). This strategy is built on three key design principles: (I) superhydrophobic body for floating on water surface, (II) light-weight, high-power actuation module capable of providing significant propulsion force within an ultrashort time, (III) well-engineered momentum transmission system for efficient kinetic energy transfer. The developed soft jumper based on these design principles advances the development of water environment related robotics.
- 28 March 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-10
Open AccessBeyond surface tension-dominated water surface jumping
Water surface jumping motions of semi-aquatic insects are primarily rely on surface tension-dominated jumping mechanism to achieve impressive jumping performance. However, this mechanism faces an inherent physical constraint: the propulsion force must remain below the threshold required to break the water surface, limiting efficient momentum acquisition. Herein, we present a water surface jumping strategy that addresses the limitations of surface tension-dominated mechanism. Our approach allows the engineered jumper to achieve a record-breaking jumping height of 18 body lengths (63 cm) and take-off velocity of 100.6 body length/s (3.52 m/s). This strategy is built on three key design principles: (I) superhydrophobic body for floating on water surface, (II) light-weight, high-power actuation module capable of providing significant propulsion force within an ultrashort time, (III) well-engineered momentum transmission system for efficient kinetic energy transfer. The developed soft jumper based on these design principles advances the development of water environment related robotics.
- Open Access
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 1513-1532
Magnetic Continuum Robot With Modular Axial Magnetization: Design, Modeling, Optimization, and Control
Magnetic continuum robots (MCRs) have become popular owing to their inherent advantages of easy miniaturization without requiring complicated transmission structures. The evolution of MCRs, from initial designs with one embedded magnet to current designs with specific magnetization profile configurations (MPCs), has significantly enhanced their dexterity. While much progress has been achieved, the quantitative index-based evaluation of deformability for different MPCs, which can assist in designing MPCs with enhanced robot deformability, has not been addressed before. Here we use “deformability” to describe the capability for body deflection when an MCR forms different global shapes under an external magnetic field. Therefore, in this paper, we propose methodologies to design and control an MCR composed of modular axially magnetized segments. To guide robot MPC design, for the first time, we introduce a quantitative index-based evaluation strategy to analyze and optimize robot deformability. Additionally, a control framework with neural network-based controllers is developed to endow the robot with two control modes: the robot tip position and orientation ( $M_{1}$ ) and the global shape ( $M_{2}$ ). The excellent performance of the learnt controllers in terms of computation time and accuracy was validated via both simulation and experimental platforms. In the experimental results, the best closed-loop control performance metrics, indicated as the mean absolute errors, were 0.254 mm and 0.626 $^\circ$ for mode $M_{1}$ and 1.564 mm and 0.086 $^\circ$ for mode $M_{2}$ .
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 1513-1532
Open AccessMagnetic Continuum Robot With Modular Axial Magnetization: Design, Modeling, Optimization, and Control
Magnetic continuum robots (MCRs) have become popular owing to their inherent advantages of easy miniaturization without requiring complicated transmission structures. The evolution of MCRs, from initial designs with one embedded magnet to current designs with specific magnetization profile configurations (MPCs), has significantly enhanced their dexterity. While much progress has been achieved, the quantitative index-based evaluation of deformability for different MPCs, which can assist in designing MPCs with enhanced robot deformability, has not been addressed before. Here we use “deformability” to describe the capability for body deflection when an MCR forms different global shapes under an external magnetic field. Therefore, in this paper, we propose methodologies to design and control an MCR composed of modular axially magnetized segments. To guide robot MPC design, for the first time, we introduce a quantitative index-based evaluation strategy to analyze and optimize robot deformability. Additionally, a control framework with neural network-based controllers is developed to endow the robot with two control modes: the robot tip position and orientation ( $M_{1}$ ) and the global shape ( $M_{2}$ ). The excellent performance of the learnt controllers in terms of computation time and accuracy was validated via both simulation and experimental platforms. In the experimental results, the best closed-loop control performance metrics, indicated as the mean absolute errors, were 0.254 mm and 0.626 $^\circ$ for mode $M_{1}$ and 1.564 mm and 0.086 $^\circ$ for mode $M_{2}$ .