XLXurui Liu

Xurui Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xurui Liu has a total of 97 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A fully hydrogel implantable patch for in situ ultrasonic monitoring of gastric leakage

    by Ye Tian, Na Li, Zhangqi Pan, Jiaxin Wang, Qiyun Hu, Zheng Dai, Xudong Xu, Yueying Yang, Sendong Zhang, Xinguo Lan, et al.

    Gastric leakage is a common and life-threatening postoperative complication, while delayed detection often leads to severe abdominal organ damage. Current radiological imaging modalities are limited in their ability to provide timely detection of gastric leakage, while the mechanical mismatch and long-term persistence of conventional electronic sensors limit their implantable applications. In this work, we developed a fully hydrogel-based ultrasonic metagel patch (USMP) for direct, real-time monitoring of gastric leakage via ultrasound imaging. The USMP incorporates a tree-ring air cell array, in which densely distributed air cells arranged in concentric rings create a strong back-scattering effect, thereby producing distinctive and stable ultrasound imaging signatures for rapid and sensitive detection. The air cells are encapsulated within biocompatible, hydrolytically degradable pH-responsive hydrogels, forming a fully hydrogel sensing architecture. The potential of the USMP for gastric leakage monitoring up to 7 days postimplantation is validated in the live rabbit model.

  • Engineering magnetic soft materials for biomedical applications

    by Xurui Liu, Neng Xia, Kai Fung Chan, Joseph Jao Yiu Sung, Philip Wai Yan Chiu, Liu Wang, Li Zhang

  • AI-driven actuation-compatible tracking for closed-loop navigation of miniature robots in vivo

    by Delin Hu, Zhaoyang Qi, Yihang Jiang, Xurui Liu, Moqiu Zhang, Haojin Yang, Li Zhang

    Miniature wireless magnetic robots (MWMRs) hold immense potential for minimally invasive interventions. Real-time tracking of MWMRs is essential for precise in vivo navigation but remains challenging. Tracking MWMRs via their emitted magnetic signals offers a viable solution, yet it has been limited to centimeter-scale robots because isolating weak MWMR signals from overwhelming actuation-induced interference becomes increasingly difficult with miniaturization. Here, we present an artificial intelligence (AI)–driven tracking system to overcome these challenges, enabling precise localization of millimeter-scale MWMRs in the presence of actuation fields. Our approach integrates a sensor array design with a transformer to accurately model and filter the interference, followed by a spatiotemporal transformer that interprets the extracted MWMR signals over a short time window to corresponding three-dimensional coordinates. Our system has been validated in a range of in vitro and in vivo experiments, demonstrating its applicability to closed-loop navigation of MWMRs in unshielded clinical settings.

  • Top Cited Papers
    Open Access

    Physically intelligent capsule robots with embodied memory and logic in the gastrointestinal tract

    by Huyue Chen, Xurui Liu, Jiahai Ma, Yishen Zhao, Chaoyu Yang, Kai-Fung Chan, Philip Wai Yan Chiu, Lei Shao, Wenming Zhang, Li Zhang, et al.

    Miniaturized medical robots offer a promising solution for minimally invasive measurements and interventions in the gastrointestinal (GI) tract. Clinical assessment of GI disorders is commonly guided by threshold-based physiological indicators, including pressure, temperature, and pH, which motivate event-triggered strategies for personalized medicine. However, identifying homeostatic dysregulation and enabling in-situ therapy remains challenging, because ingestible robotic systems must tightly integrate sensing, decision-making, and actuation under severe constraints of size, power, and biosafety. Inspired by the autonomy of microorganisms that operate without neural processing, this work introduces physically intelligent capsule robots (PI Capbots) that enable homeostatic monitoring and targeted delivery within the GI tract, without relying on centralized electronic control. Through embodied stimuli-responsive memory and logic, PI Capbots effectively distill rich, detailed, and redundant physiological information into a small set of decoupled and event-triggered outputs suitable for operations in in vivo environments. In each PI Capbot, multistable metamaterials encode intraluminal pressure as mechanical memory, programmable hydrogels implement orthogonal sensing and logic operations, and helical fibers enable multimodal locomotion. Ex vivo and in vivo studies in large animal models demonstrate the efficacy, robustness, and reproducibility of PI Capbots, highlighting its potential for their translational medical applications.


  • Miniature magneto-ultrasonic machines for wireless robotic sensing and manipulation

    by Xurui Liu, Hanchuan Tang, Na Li, Linjie He, Ye Tian, Bo Hao, Junnan Xue, Chaoyu Yang, Joseph Jao Yiu Sung, Li Zhang, et al.

    Intelligent miniature systems capable of wireless sensing and manipulation hold considerable promise for advancing biomedical applications. However, the development of these systems has been substantially hindered by sensing-actuation incompatibility at small scales. To overcome this challenge, we propose a robotic sensing approach that integrates embedded ultrasonic soft sensors (EUSSs) with magnetic actuators, resulting in a wireless sensor-integrated miniature machine with seamless integration and minimal interference between fields. The EUSS, with its compact dimensions (1.3 millimeters by 1.3 millimeters by 1.6 millimeters), softness (98 kilopascals), and lightweight design (4.6 milligrams), is compatible with both soft and rigid components in terms of deformability and size. By engineering onboard transducers and using passive ultrasound communication along with external magnetic fields, we could wirelessly detect and regulate environmental parameters such as force, vibration, viscosity, and temperature. Demonstrations in rabbit and porcine models show the potential for robotic feedback control, accurate drug dosing, and in situ physiological monitoring, paving the way for real-world applications of intelligent miniature machines.


  • Photocatalytic microrobots for treating bacterial infections deep within sinuses

    by Haidong Yu, Xurui Liu, Yabin Zhang, Jie Shen, Xijun Liu, Shubo Liu, Xiangyu Wang, Bonan Sun, Huihui Du, Lin Xu, et al.

    Microrobotic techniques are promising for treating biofilm infections located deep within the human body. However, the presence of highly viscous pus presents a formidable biological barrier, severely restricting targeted and minimally invasive treatments. In addition, conventional antibacterial agents exhibit limited payload integration with microrobotic systems, further compromising therapeutic efficiency. In this study, we propose a photocatalytic microrobot through a magnetically guided, optical fiber–assisted therapeutic platform specifically designed to treat bacterial infections in deep mucosal cavities. The microrobots comprising copper (Cu) single atom–doped bismuth oxoiodide (BiOI), termed CBMRs, can be guided and tracked by real-time x-ray imaging. Under external magnetic actuation, the illuminated region from the magnetically guided optical fiber synchronously follows the CBMR swarm, enabling effective antibacterial action at targeted infection sites. Upon continuous visible-light irradiation, the resultant photothermal effect substantially reduces the viscosity of pus on inflamed mucosal tissues, enhancing the penetration capability of the CBMR swarm by more than threefold compared with baseline conditions. Concurrently, atomic-level design of CBMRs facilitates robust generation of reactive oxygen species, enabling efficient biofilm disruption and reductions in bacterial viability. We validated the effectiveness of this integrated optical fiber–assisted microrobotic platform in a rabbit sinusitis model in vivo, demonstrating its potential for clinically relevant infection therapy.


  • Top Cited Papers
    Open Access

    A magnetically actuated microcatheter with soft rotatable tip for enhanced endovascular access and treatment efficiency

    by Moqiu Zhang, Lidong Yang, Haojin Yang, Lin Su, Junnan Xue, Qinglong Wang, Bo Hao, Yihang Jiang, Kai Fung Chan, Joseph Jao Yiu Sung, et al.

    Endovascular interventions require fast access to affected regions, followed by effective treatment. Catheterizations are effective approaches for treating vascular diseases; however, they face challenges in accessibility, efficiency, and invasiveness in narrow, tortuous vascular systems. This study presents a submillimeter magnetically actuated soft rotatable-tipped microcatheter (MSRM) designed to access small blood vessels and provide efficient, minimally invasive therapeutic interventions for blood clot treatment. The MSRM’s rotatable tip design enhances accessibility and navigation speed through a rotation-assisted active steering strategy. Improved blood clot treatment efficiency is achieved through the MSRM’s multifunctionality: It can accelerate drug-blood clot interactions, mechanically break down blood clots, and retrieve clot debris. The low invasiveness is attributed to the soft material design and conservative actuation strategy. The performance of the MSRM is validated in both in vitro phantom studies and in vivo rabbit models, and the invasiveness is evaluated using a human placenta model.


  • Top Cited Papers

    An implantable hydrogel-based phononic crystal for continuous and wireless monitoring of internal tissue strains

    by Ye Tian, Yueying Yang, Hanchuan Tang, Jiaxin Wang, Na Li, Yifan Cheng, Tianyu Kang, Jiarui Tang, Mengyuan Zhou, Wei Chen, et al.

    Conventional implantable electronic sensors for continuous monitoring of internal tissue strains are yet to match the biomechanics of tissues while maintaining biodegradability, biocompatibility and wireless monitoring capability. Here we present a two-dimensional phononic crystal composed of periodic air columns in soft hydrogel, which was named ultrasonic metagel, and we demonstrate its use as implantable sensor for continuous and wireless monitoring of internal tissue strains. The metagel’s deformation shifts its ultrasonic bandgap, which can be wirelessly detected by an external ultrasonic probe. We demonstrate ex vivo the ability of the metagel sensor for monitoring tissue strains on porcine tendon, wounded tissue and heart. In live pigs, we further demonstrate the ability of the metagel to monitor tendon stretching, respiration and heartbeat, working stably during 30 days of implantation, and we loaded the metagel with growth factors to achieve different healing rates in subcutaneous wounds. The metagel results almost completely degraded 12 weeks after implantation. Our finding highlights the clinical potential of the ultrasonic sensor for tendon rehabilitation monitoring and drug delivery efficacy evaluation.


  • Open Access

    Beyond surface tension-dominated water surface jumping

    by Xin Wang, Neng Xia, Chengfeng Pan, Jinsheng Zhao, Bo Hao, Lin Su, Dongdong Jin, Qingsong Xu, Xurui Liu, Xingyu Hou, et al.

    Water surface jumping motions of semi-aquatic insects are primarily rely on surface tension-dominated jumping mechanism to achieve impressive jumping performance. However, this mechanism faces an inherent physical constraint: the propulsion force must remain below the threshold required to break the water surface, limiting efficient momentum acquisition. Herein, we present a water surface jumping strategy that addresses the limitations of surface tension-dominated mechanism. Our approach allows the engineered jumper to achieve a record-breaking jumping height of 18 body lengths (63 cm) and take-off velocity of 100.6 body length/s (3.52 m/s). This strategy is built on three key design principles: (I) superhydrophobic body for floating on water surface, (II) light-weight, high-power actuation module capable of providing significant propulsion force within an ultrashort time, (III) well-engineered momentum transmission system for efficient kinetic energy transfer. The developed soft jumper based on these design principles advances the development of water environment related robotics.


  • Open Access

    Magnetic Continuum Robot With Modular Axial Magnetization: Design, Modeling, Optimization, and Control

    by Yanfei Cao, Mingxue Cai, Bonan Sun, Zhaoyang Qi, Junnan Xue, Yihang Jiang, Bo Hao, Jiaqi Zhu, Xurui Liu, Chaoyu Yang, et al.

    Magnetic continuum robots (MCRs) have become popular owing to their inherent advantages of easy miniaturization without requiring complicated transmission structures. The evolution of MCRs, from initial designs with one embedded magnet to current designs with specific magnetization profile configurations (MPCs), has significantly enhanced their dexterity. While much progress has been achieved, the quantitative index-based evaluation of deformability for different MPCs, which can assist in designing MPCs with enhanced robot deformability, has not been addressed before. Here we use “deformability” to describe the capability for body deflection when an MCR forms different global shapes under an external magnetic field. Therefore, in this paper, we propose methodologies to design and control an MCR composed of modular axially magnetized segments. To guide robot MPC design, for the first time, we introduce a quantitative index-based evaluation strategy to analyze and optimize robot deformability. Additionally, a control framework with neural network-based controllers is developed to endow the robot with two control modes: the robot tip position and orientation ( $M_{1}$ ) and the global shape ( $M_{2}$ ). The excellent performance of the learnt controllers in terms of computation time and accuracy was validated via both simulation and experimental platforms. In the experimental results, the best closed-loop control performance metrics, indicated as the mean absolute errors, were 0.254 mm and 0.626 $^\circ$ for mode $M_{1}$ and 1.564 mm and 0.086 $^\circ$ for mode $M_{2}$ .