Elvio D. Amato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elvio D. Amato has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Andrea F. G. Gargano
Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, Amsterdam 1098 XH, The Netherlands
2 shared publications - Alexandros Nikolopoulos
University of Amsterdam
1 shared publication - Andrea Cerrato
Department of Chemistry, Sapienza University of Rome, Piazzale Aldo Moro 5, Rome 00185, Italy
1 shared publication - Erik Emke
KWR Watercycle Research Institute, Chemical Water Quality and Health, P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands
1 shared publication - Lapo Renai
Van ‘t Hoff Institute for Molecular Sciences (HIMS), University of Amsterdam, 1090 GD, Amsterdam, Netherlands
1 shared publication - Massimo Del Bubba
Department of Chemistry, University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino, Florence, Italy
1 shared publication
Latest Publications
- Open Access
- 30 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
A Novel Chemical Space Dependent Strategy for Compound Selection in Non-Target LC–HRMS Method Development Using Physicochemical and Structural Data
The virtual chemical space of substances, including emerging contaminants relevant to the environment and exposome, is in continuous expansion. The comprehensive measure of specific regions of chemical (sub)space relies on non-targeted analysis (NTA) using liquid chromatography high-resolution mass spectrometry (LC–HRMS). Internal standards are generally used to balance selectivity and sensitivity during NTA sample preparation and method development, assuming linearity between structure and behavior of all chemicals of interest. Since this assumption does not hold for wide and complex chemical subspaces, the actual measured space by NTA methods is consequently narrowed to a reduced set of chemically/structurally similar compounds. To understand the true coverage of the measurable chemical space by NTA methods, we present a data-driven strategy enabling the unbiased sampling of structures for LC–HRMS method development from a vast chemical subspace of interest (e.g., US-EPA CompTox >1 million chemicals). This workflow mines candidate structures maximizing their physicochemical diversity for reliable chemical subspace coverage. Measurable compound lists (MCLs) are effectively sampled using precomputed PubChem physicochemical properties (e.g., molecular weight and XLogP) and predicted mobility and ionization efficiency from molecular fingerprints. This approach significantly advances the selection of heterogeneous structures compatible with LC–HRMS analysis for NTA method development, validation, and method space boundary assessment while preserving the original diversity of the selected chemical space. The MCL sampled from CompTox space exhibited a greater chemical coverage and a broader predicted LC–HRMS applicability compared to common “watch list” contaminants.
- 30 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessA Novel Chemical Space Dependent Strategy for Compound Selection in Non-Target LC–HRMS Method Development Using Physicochemical and Structural Data
The virtual chemical space of substances, including emerging contaminants relevant to the environment and exposome, is in continuous expansion. The comprehensive measure of specific regions of chemical (sub)space relies on non-targeted analysis (NTA) using liquid chromatography high-resolution mass spectrometry (LC–HRMS). Internal standards are generally used to balance selectivity and sensitivity during NTA sample preparation and method development, assuming linearity between structure and behavior of all chemicals of interest. Since this assumption does not hold for wide and complex chemical subspaces, the actual measured space by NTA methods is consequently narrowed to a reduced set of chemically/structurally similar compounds. To understand the true coverage of the measurable chemical space by NTA methods, we present a data-driven strategy enabling the unbiased sampling of structures for LC–HRMS method development from a vast chemical subspace of interest (e.g., US-EPA CompTox >1 million chemicals). This workflow mines candidate structures maximizing their physicochemical diversity for reliable chemical subspace coverage. Measurable compound lists (MCLs) are effectively sampled using precomputed PubChem physicochemical properties (e.g., molecular weight and XLogP) and predicted mobility and ionization efficiency from molecular fingerprints. This approach significantly advances the selection of heterogeneous structures compatible with LC–HRMS analysis for NTA method development, validation, and method space boundary assessment while preserving the original diversity of the selected chemical space. The MCL sampled from CompTox space exhibited a greater chemical coverage and a broader predicted LC–HRMS applicability compared to common “watch list” contaminants.
- Open Access
- 3 November 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Expanding the chemical coverage of polar compounds in water analysis by coupling supercritical fluid with hydrophilic interaction chromatography high-resolution mass spectrometry
Background: Persistent and mobile organic compounds (PMOC) are of great concern for water quality and human health. The recent improvement and availability of high-resolution mass spectrometry in combination with liquid chromatography have widely expanded the potential of analytical workflows for their detection and quantitation in water. Given their high polarity, the detection of some PMOC requires alternative techniques to reversed-phase chromatography, such as hydrophilic interaction liquid chromatography (HILIC) and supercritical fluid chromatography (SFC). Unified chromatography (UC), an SFC gradient in which the state of the mobile phase changes continuously from supercritical to liquid at 100% polar co-solvent, has shown potential for the analysis of very polar compounds. Results: In the present study, for the first time, a UC-HILIC method coupled with high- resolution mass spectrometry was set up for PMOC analysis in water. SFC and HILIC gradients were run sequentially on the same bare-silica column, with the first separation running to 100% modifier (UC) followed by a HILIC gradient transitioning to water. The UC and UC-HILIC gradients were previously optimized on a mix of 18 representative PMOC to assess solvent and mobile phase composition and for the instrumental system setup. The final method was employed for the analysis of water samples in comparison with a traditional reversed-phase separation, resulting in a significant increase in the number of annotated polar PMOC, including compounds listed in the Candidate List of substances of very high concern for Authorisation by the European Chemicals Agency. Significance: The proposed approach represents a robust alternative to traditional methods for broadening the chemical space of separation and mass spectrometric detection. The introduction of the HILIC section of the gradient was necessary for the elution of strongly retained compounds on the silica phase, thus also reducing the amount of compounds that would be stuck onto the phase of the column, resulting in possible irreproducibility, pressure increase, and loss of efficiency in the compound separation.
- 3 November 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessExpanding the chemical coverage of polar compounds in water analysis by coupling supercritical fluid with hydrophilic interaction chromatography high-resolution mass spectrometry
Background: Persistent and mobile organic compounds (PMOC) are of great concern for water quality and human health. The recent improvement and availability of high-resolution mass spectrometry in combination with liquid chromatography have widely expanded the potential of analytical workflows for their detection and quantitation in water. Given their high polarity, the detection of some PMOC requires alternative techniques to reversed-phase chromatography, such as hydrophilic interaction liquid chromatography (HILIC) and supercritical fluid chromatography (SFC). Unified chromatography (UC), an SFC gradient in which the state of the mobile phase changes continuously from supercritical to liquid at 100% polar co-solvent, has shown potential for the analysis of very polar compounds. Results: In the present study, for the first time, a UC-HILIC method coupled with high- resolution mass spectrometry was set up for PMOC analysis in water. SFC and HILIC gradients were run sequentially on the same bare-silica column, with the first separation running to 100% modifier (UC) followed by a HILIC gradient transitioning to water. The UC and UC-HILIC gradients were previously optimized on a mix of 18 representative PMOC to assess solvent and mobile phase composition and for the instrumental system setup. The final method was employed for the analysis of water samples in comparison with a traditional reversed-phase separation, resulting in a significant increase in the number of annotated polar PMOC, including compounds listed in the Candidate List of substances of very high concern for Authorisation by the European Chemicals Agency. Significance: The proposed approach represents a robust alternative to traditional methods for broadening the chemical space of separation and mass spectrometric detection. The introduction of the HILIC section of the gradient was necessary for the elution of strongly retained compounds on the silica phase, thus also reducing the amount of compounds that would be stuck onto the phase of the column, resulting in possible irreproducibility, pressure increase, and loss of efficiency in the compound separation.
- Open Access
- 28 February 2024
- Published by MDPI AG in Environments
- Vol. 11 (3) , 46
Linking Clusters of Micropollutants in Surface Water to Emission Sources, Environmental Conditions, and Substance Properties
Water quality monitoring programs yield a wealth of data. It is often unclear why a certain substance occurs in higher concentrations at a certain location or time. In this study, substances were considered in clusters with co-varying concentrations rather than in isolation. A total of 196 substance clusters at 19 monitoring sites in the rivers Rhine and Meuse were identified. A total of nine clusters were found repeatedly with a similar composition at different monitoring sites. Several environmental conditions and substance properties could be linked to clusters. In addition, overlap with reference substance lists was determined. These lists group multiple substances according to emission sources, substance types, or type of use. The reference substance lists revealed that Rhine and Meuse are similarly affected. The nine ‘repeating clusters’ were analyzed in more detail to identify drivers. For instance, a repeating cluster with herbicides was specifically linked to high temperatures and a high number of hours in the sun per day, e.g., summer conditions. A cluster containing polychlorinated biphenyls, identified as persistent and with a high tendency to bind organic matter, was linked to high river discharge and attributed to a potential release from sediment resuspension. Not all substances could be clustered, because their concentration did not structurally vary in the same way as other substances. The presented explorative cluster analyses, along with the obtained relations with substance properties, local environmental conditions, and reference substance lists, may facilitate the reconstruction of the processes that lead to the observed variation in concentrations. This knowledge can subsequently be used by water managers to improve water quality.
- 28 February 2024
- Published by MDPI AG in Environments
- Vol. 11 (3) , 46
Open AccessLinking Clusters of Micropollutants in Surface Water to Emission Sources, Environmental Conditions, and Substance Properties
Water quality monitoring programs yield a wealth of data. It is often unclear why a certain substance occurs in higher concentrations at a certain location or time. In this study, substances were considered in clusters with co-varying concentrations rather than in isolation. A total of 196 substance clusters at 19 monitoring sites in the rivers Rhine and Meuse were identified. A total of nine clusters were found repeatedly with a similar composition at different monitoring sites. Several environmental conditions and substance properties could be linked to clusters. In addition, overlap with reference substance lists was determined. These lists group multiple substances according to emission sources, substance types, or type of use. The reference substance lists revealed that Rhine and Meuse are similarly affected. The nine ‘repeating clusters’ were analyzed in more detail to identify drivers. For instance, a repeating cluster with herbicides was specifically linked to high temperatures and a high number of hours in the sun per day, e.g., summer conditions. A cluster containing polychlorinated biphenyls, identified as persistent and with a high tendency to bind organic matter, was linked to high river discharge and attributed to a potential release from sediment resuspension. Not all substances could be clustered, because their concentration did not structurally vary in the same way as other substances. The presented explorative cluster analyses, along with the obtained relations with substance properties, local environmental conditions, and reference substance lists, may facilitate the reconstruction of the processes that lead to the observed variation in concentrations. This knowledge can subsequently be used by water managers to improve water quality.