Abstract
This letter proposes a millimeter-wave radar sensing system for adaptive measurement of the heart interbeat interval under diverse measurement environments. Millimeter-wave radar provides high-resolution sensing of micrometer-scale heartbeat-induced skin motion. However, the signal-to-noise ratio of the heartbeat component contained in the measured displacement varies substantially across postures and individuals, making it difficult to maintain stable measurement performance. To address this challenge, we introduce a probabilistic sensing model for heartbeat-induced micro-motions with heteroscedastic Gaussian process regression-based compensation method. This approach adaptively stabilizes the radar-based heartbeat measurement even in diverse measurement conditions. Experiments with five participants in three seating orientations demonstrated that the proposed sensing method reduced heart interbeat interval error by 63.3%, reduced heart rate error by 60.1%, and improved heart rate measurement accuracy by 21.2 points compared with a conventional radar-based measurement method.

This publication has 17 references indexed in Scilit: