Muhammad Nurjati Hidayat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Muhammad Nurjati Hidayat has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Haruichi Kanaya
Department of Electronics, Kyushu University, Fukuoka, Japan
4 shared publications - Hemanta Hazarika
Kyushu University, Fukuoka, Japan
3 shared publications Hemanta Hazarika
Kyushu University
2 shared publicationsMasanori Murai
Shimizu Corporation
2 shared publications- Ery Suhartanto
Universitas Brawijaya
1 shared publication - Evi Nur Cahya
University of Brawijaya, Faculty of Engineering, Jl. MT Haryono 167, 65145, Malang Indonesia
1 shared publication
Latest Publications
- Open Access
- 8 December 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (6) , 29935-29941
A Comparative Evaluation of Bias Correction Techniques for Improving GPM-IMERG Precipitation Data in the Welang Watershed, Indonesia
Precise precipitation information underpins hydrological modeling, water resource planning, and hazard mitigation; yet, gauge coverage in many Indonesian catchments is sparse. The GPM-IMERG product provides 0.1°/30-min rainfall estimates, however, systematic biases limit its operational value. Five benchmark correction techniques were evaluated: Linear Scaling (LS), Linear Regression (LR), Genetic-Algorithm-based Correction Factor (GA-CF), Local Intensity Scaling (LOCI), and Power Transformation (PT) against daily observations from seven gauges in the Welang Watershed (2001–2020). LS delivered the most consistent improvement (NSE = 0.87, R = 0.92, RSR = 0.36), reducing the residual error by 30% relative to the next-best method. LR, GA-CF, and LOCI enhanced seasonal patterns (NSE ≈ 0.85), while PT provided complementary gains for moderate events but remained sub-optimal for extremes. The refined IMERG series met the accuracy thresholds proposed for reservoir operations, providing a readily deployable rainfall input for data-scarce, topographically complex tropical watersheds.
- 8 December 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (6) , 29935-29941
Open AccessA Comparative Evaluation of Bias Correction Techniques for Improving GPM-IMERG Precipitation Data in the Welang Watershed, Indonesia
Precise precipitation information underpins hydrological modeling, water resource planning, and hazard mitigation; yet, gauge coverage in many Indonesian catchments is sparse. The GPM-IMERG product provides 0.1°/30-min rainfall estimates, however, systematic biases limit its operational value. Five benchmark correction techniques were evaluated: Linear Scaling (LS), Linear Regression (LR), Genetic-Algorithm-based Correction Factor (GA-CF), Local Intensity Scaling (LOCI), and Power Transformation (PT) against daily observations from seven gauges in the Welang Watershed (2001–2020). LS delivered the most consistent improvement (NSE = 0.87, R = 0.92, RSR = 0.36), reducing the residual error by 30% relative to the next-best method. LR, GA-CF, and LOCI enhanced seasonal patterns (NSE ≈ 0.85), while PT provided complementary gains for moderate events but remained sub-optimal for extremes. The refined IMERG series met the accuracy thresholds proposed for reservoir operations, providing a readily deployable rainfall input for data-scarce, topographically complex tropical watersheds.
- Open Access
Calibration and Performance Evaluation of Cost-Effective Capacitive Moisture Sensor in Slope Model Experiments
Understanding the factors that contribute to slope failures, such as soil saturation, is essential for mitigating rainfall-induced landslides. Cost-effective capacitive soil moisture sensors have the potential to be widely implemented across multiple sites for landslide early warning systems. However, these sensors need to be calibrated for specific applications to ensure high accuracy in readings. In this study, a soil-specific calibration was performed in a laboratory setting to integrate the soil moisture sensor with an automatic monitoring system using the Internet of Things (IoT). This research aims to evaluate a low-cost soil moisture sensor (SKU:SEN0193) and develop calibration equations for the purpose of slope model experiment under artificial rainfall condition using silica sand. The results indicate that a polynomial function is the best fit, with a coefficient of determination (R2) ranging from 0.918 to 0.983 and a root mean square error (RMSE) ranging from 1.171 to 2.488. The calibration equation was validated through slope model experiments, with soil samples taken from the models after the experiment finished. Overall, the moisture content readings from the sensors showed approximately a 12% deviation from the actual moisture content. The findings suggest that the cost-effective capacitive soil moisture sensor has the potential to be used for the development of landslide early warning system.
Open AccessCalibration and Performance Evaluation of Cost-Effective Capacitive Moisture Sensor in Slope Model Experiments
Understanding the factors that contribute to slope failures, such as soil saturation, is essential for mitigating rainfall-induced landslides. Cost-effective capacitive soil moisture sensors have the potential to be widely implemented across multiple sites for landslide early warning systems. However, these sensors need to be calibrated for specific applications to ensure high accuracy in readings. In this study, a soil-specific calibration was performed in a laboratory setting to integrate the soil moisture sensor with an automatic monitoring system using the Internet of Things (IoT). This research aims to evaluate a low-cost soil moisture sensor (SKU:SEN0193) and develop calibration equations for the purpose of slope model experiment under artificial rainfall condition using silica sand. The results indicate that a polynomial function is the best fit, with a coefficient of determination (R2) ranging from 0.918 to 0.983 and a root mean square error (RMSE) ranging from 1.171 to 2.488. The calibration equation was validated through slope model experiments, with soil samples taken from the models after the experiment finished. Overall, the moisture content readings from the sensors showed approximately a 12% deviation from the actual moisture content. The findings suggest that the cost-effective capacitive soil moisture sensor has the potential to be used for the development of landslide early warning system.
- 13 November 2024
- Published by Springer Nature in Indian Geotechnical Journal
- Vol. 56 (7) , 3375-3390
Development and Evaluation of Landslide Early Warning System for Mitigating Rainfall Induced Disasters
- 13 November 2024
- Published by Springer Nature in Indian Geotechnical Journal
- Vol. 56 (7) , 3375-3390
Development and Evaluation of Landslide Early Warning System for Mitigating Rainfall Induced Disasters
- Open Access
- 29 October 2024
- Published by MDPI AG in Preprints.org
Calibration and Performance Evaluation of Cost-effective Capacitive Moisture Sensor in a Slope Model Experiments
Understanding the factors that contribute to slope failures, such as soil saturation, is essential for mitigating rainfall-induced landslides. Cost-effective capacitive soil moisture sensors have the po-tential to be widely implemented across multiple sites for landslide early warning systems. How-ever, these sensors need to be calibrated for specific applications to ensure high accuracy in readings. In this study, a soil-specific calibration was performed in a laboratory setting to integrate the soil moisture sensor with an automatic monitoring system using the Internet of Things (IoT). This re-search aims to evaluate a low-cost soil moisture sensor (SKU:SEN0193) and develop calibration equations for the purpose of slope model experiment under artificial rainfall condition using silica sand. The results indicate that a polynomial function is the best fit, with a coefficient of determi-nation (R²) ranging from 0.92 to 0.98 and a root mean square error (RMSE) ranging from 1.17 to 2.67. The calibration equation was validated through slope model experiments, with soil samples taken from the model after the experiment finished. Overall, the moisture content readings from the sensors showed approximately a 10% deviation from the actual moisture content. The findings suggest that the cost-effective capacitive soil moisture sensors has the potential to be used for the development of landslide early warning system.
- 29 October 2024
- Published by MDPI AG in Preprints.org
Open AccessCalibration and Performance Evaluation of Cost-effective Capacitive Moisture Sensor in a Slope Model Experiments
Understanding the factors that contribute to slope failures, such as soil saturation, is essential for mitigating rainfall-induced landslides. Cost-effective capacitive soil moisture sensors have the po-tential to be widely implemented across multiple sites for landslide early warning systems. How-ever, these sensors need to be calibrated for specific applications to ensure high accuracy in readings. In this study, a soil-specific calibration was performed in a laboratory setting to integrate the soil moisture sensor with an automatic monitoring system using the Internet of Things (IoT). This re-search aims to evaluate a low-cost soil moisture sensor (SKU:SEN0193) and develop calibration equations for the purpose of slope model experiment under artificial rainfall condition using silica sand. The results indicate that a polynomial function is the best fit, with a coefficient of determi-nation (R²) ranging from 0.92 to 0.98 and a root mean square error (RMSE) ranging from 1.17 to 2.67. The calibration equation was validated through slope model experiments, with soil samples taken from the model after the experiment finished. Overall, the moisture content readings from the sensors showed approximately a 10% deviation from the actual moisture content. The findings suggest that the cost-effective capacitive soil moisture sensors has the potential to be used for the development of landslide early warning system.
- Open Access
- 19 July 2024
- Published by Institute of Research and Community Services Diponegoro University (LPPM UNDIP) in MEDIA KOMUNIKASI TEKNIK SIPIL
- Vol. 30 (1) , 126-134
Operation of Flushing Gate on Sediment Flushing Efficiency: A Case Study of Alale Weir
This study discuss about hydraulic physical model tests of Alale weir to ensure hydraulic flow behaviour of design flood, condition on downstream of weir, and sediment flushing. In this study, observation were made on a physical hydraulic model in the laboratory with a scale of 1 : 50. Flushing tests were carried out to determine effectivity of the flushing, condition of sedimentation or scouring that occurred at downstream. Alale Weir has 3 flushing gate on the right side of the weir. Flushing is carried out using discharge Q25yr with a flowing duration of 1 hour. Flushing gate has considered quite effective in flushing sediment from upstream of weir. The sediment carried is almost 50% in all flushing scenarios. 6th flushing scenario (gate 1 and 2 were closed and gate 3 was fully opened) has the highest efficiency, 53.81%.
- 19 July 2024
- Published by Institute of Research and Community Services Diponegoro University (LPPM UNDIP) in MEDIA KOMUNIKASI TEKNIK SIPIL
- Vol. 30 (1) , 126-134
Open AccessOperation of Flushing Gate on Sediment Flushing Efficiency: A Case Study of Alale Weir
This study discuss about hydraulic physical model tests of Alale weir to ensure hydraulic flow behaviour of design flood, condition on downstream of weir, and sediment flushing. In this study, observation were made on a physical hydraulic model in the laboratory with a scale of 1 : 50. Flushing tests were carried out to determine effectivity of the flushing, condition of sedimentation or scouring that occurred at downstream. Alale Weir has 3 flushing gate on the right side of the weir. Flushing is carried out using discharge Q25yr with a flowing duration of 1 hour. Flushing gate has considered quite effective in flushing sediment from upstream of weir. The sediment carried is almost 50% in all flushing scenarios. 6th flushing scenario (gate 1 and 2 were closed and gate 3 was fully opened) has the highest efficiency, 53.81%.
- 1 June 2024
- Published by Springer Nature
- p. 772-780
Application of Early Warning System for Monitoring Landslide Vulnerability of Slope
- 1 June 2024
- Published by Springer Nature
- p. 772-780
Application of Early Warning System for Monitoring Landslide Vulnerability of Slope
- 8 March 2024
- Published by Springer Nature
- p. 47-56
Evaluation of Landslide Triggering Mechanism During Rainfall in Slopes Containing Vertical Cracks
- 8 March 2024
- Published by Springer Nature
- p. 47-56
Evaluation of Landslide Triggering Mechanism During Rainfall in Slopes Containing Vertical Cracks