VSVivek M. Mbbs Singh

Vivek M. Mbbs Singh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vivek M. Mbbs Singh has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of digital cataract workflow on time and resource efficiencies in cataract surgery: time and motion study

    by Naren Mbbs Shetty, Aishwarya Mbbs Saxena, Vivek M. Mbbs Singh, Merle Mbbs Fernandes, Prashant Mbbs Garg, Manoj Venkiteshwar

    Purpose: To compare time and resource saving with integration of digital cataract workflow to the existing workflow in high-volume cataract surgery clinics. Setting: L V Prasad Eye Institute, Hyderabad, India (site 1), and Narayana Nethralaya, Bengaluru, India (site 2). Design: Prospective, time and motion. Methods: The total time to complete each step (preoperative measurements, surgical planning, and surgical procedures) of the cataract workflow, number of data fields entered, and support staff required for both workflows were recorded. All study measurements were determined first for existing electronic medical record (EMR) cataract workflow followed by digital workflow (integrated data management system with data reviewer, surgical planner, and data transfer to operating room) at both sites. Results: A total of 85 (site 1, 44; site 2, 41) cataract workflows were analyzed. The integration of digital workflow into the site's existing EMR workflow reduced the mean time for preoperative measurements by 25.3% (P = .006), surgical planning by 55.1% (P = .008), and surgical procedures by 22.6% (P = .002). The mean ± SD overall time for the surgery was significantly shorter in the digital group (887.3 ± 103.3 vs 1271.3 ± 300.7 seconds; P < .0001). For both sites, the number of data fields recorded and number of support staff needed were significantly lesser for the digital workflow (P < .0001, for both). Conclusions: Integration of digital workflow significantly reduced the overall cataract surgery time, variability of overall time, number of data fields recorded, and resource utilization. Complete digitalization has important implications for improving the efficiency and standardization of cataract surgery workflow.


  • Peripheral defocus of monofocal intraocular lenses

    by Ramya Natarajan, Bianca Maceo Heilman, Arthur Ho, Vivek M. Singh, Marco Ruggeri, Ashik Mohamed, Jagadesh C. Reddy, Jean-Marie A. Parel, Pravin K. Vadavalli, Fabrice Manns

    Purpose: To quantify the angular dependence of monofocal intraocular lens (IOL) power. Setting: Ophthalmic Biophysics Laboratory, Kallam Anji Reddy campus, L V Prasad Eye Institute, Hyderabad, India. Design: Laboratory study. Methods: Experiments were performed on IOLs from 2 different manufacturers (APPALENS 207, Appasamy Associates and SN60WF, Alcon Laboratories, Inc.). IOL powers ranged from 17 to 25 diopters (D). The IOLs were mounted in a fluid-filled chamber, and the on-axis and off-axis powers were measured using a laser ray tracing system over the central 3 mm zone with delivery angles ranging from −30 to +30 degrees in 5-degree increments. The position of the best focus was calculated for each IOL at each angle. The angular dependence of IOL power was compared with theoretical predictions. Results: Peripheral defocus increased significantly with increasing incidence angle and power. The peripheral defocus at ±30 degrees increased from 5.8 to 8.5 D when the power increased from 17.5 to 24.5 D for APPALENS 207 and from 4.9 to 7.4 D when the power increased from 17 to 25 D for SN60WF. The mean difference between the measured and theoretical tangential power at ±30 degrees was 0.50 ± 0.16 D for the APPALENS 207 and −0.40 ± 0.10 D for the SN60WF, independent of IOL power. Conclusions: IOLs introduce a significant amount of peripheral defocus which varies significantly with IOL power and design. Given that peripheral defocus is related to lens power, replacement of the crystalline lens (approximately 24 D) with an IOL will produce a significant difference in peripheral defocus profile after surgery.