Shen Fu Tseng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Shen Fu Tseng has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Zhi Ting Ye
National Chung Cheng University
4 shared publications - Shang Xuan Tsou
Department of Mechanical Engineering, Advanced Institute of Manufacturing With High-Tech Innovations, National Chung Cheng University, Chia-Yi, Taiwan
3 shared publications - Hsin Ching Kuo
Department of Mechanical Engineering, National Chung Cheng University, Chiayi, Taiwan
2 shared publications - Chi Wu Ke
Department of Mechanical Engineering, National Chung Cheng University, Chia Yi, Taiwan
1 shared publication - Jun Yi Wu
Department of Mechanical Engineering, Advanced Institute of Manufacturing With High-Tech Innovations, National Chung Cheng University, Chia-Yi, Taiwan
1 shared publication - Kuang-Chen Yen
Department of Medical Imaging, National Taiwan University Hospital, Taipei, Taiwan
1 shared publication
Latest Publications
- Open Access
- 24 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (3) , 1-6
Using an LED Light Source Coupled With Spectral Image Analysis for Non-Invasive Glucose Detection
Glucose monitoring is critical for diabetes patients. However, invasive blood testing carries the risk of infection if wound care is not handled properly and non-invasive glucose testing devices are often bulky and not portable. Therefore, our study proposes the use of white light-emitting diode (LED) bulbs with different color temperatures as a light source. Additionally, ammonium metavanadate and sulfuric acid were used to prepare the detection solution instead of peroxidase to produce color, after which images were captured using a smartphone. The red, green, and blue (RGB) channels were then separated and converted into grayscale images. The average grayscale value changes in the images were analyzed to determine the linear relationship between glucose concentration and grayscale values, thus allowing for non-invasive quantitative glucose testing. When using a 3000K white LED bulb as the light source, the grayscale values of the RGB channels analyzed from the images exhibited a linear relationship with the glucose concentration at a 0.1–10 mM range. The regression equation for the red channel was y = −3.1184x+148.2, with a coefficient of determination (R 2 ) of 0.9165, a limit of detection (LOD) of 2.27 mM, and a limit of quantification (LOQ) of 6.88 mM. The proposed method of using white LED bulbs as a detection light source combined with image analysis can be used to determine whether glucose concentrations in blood, saliva, or tears are higher than normal, providing the advantages of rapid, highly sensitive, and non-invasive testing.
- 24 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (3) , 1-6
Open AccessUsing an LED Light Source Coupled With Spectral Image Analysis for Non-Invasive Glucose Detection
Glucose monitoring is critical for diabetes patients. However, invasive blood testing carries the risk of infection if wound care is not handled properly and non-invasive glucose testing devices are often bulky and not portable. Therefore, our study proposes the use of white light-emitting diode (LED) bulbs with different color temperatures as a light source. Additionally, ammonium metavanadate and sulfuric acid were used to prepare the detection solution instead of peroxidase to produce color, after which images were captured using a smartphone. The red, green, and blue (RGB) channels were then separated and converted into grayscale images. The average grayscale value changes in the images were analyzed to determine the linear relationship between glucose concentration and grayscale values, thus allowing for non-invasive quantitative glucose testing. When using a 3000K white LED bulb as the light source, the grayscale values of the RGB channels analyzed from the images exhibited a linear relationship with the glucose concentration at a 0.1–10 mM range. The regression equation for the red channel was y = −3.1184x+148.2, with a coefficient of determination (R 2 ) of 0.9165, a limit of detection (LOD) of 2.27 mM, and a limit of quantification (LOQ) of 6.88 mM. The proposed method of using white LED bulbs as a detection light source combined with image analysis can be used to determine whether glucose concentrations in blood, saliva, or tears are higher than normal, providing the advantages of rapid, highly sensitive, and non-invasive testing.
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 17630-17637
A Lightweight Paper Sensor for Real-Time Detection of Human Serum Albumin Based on Imaging and Spectroscopy Methods
Detecting albumin levels quantitatively is challenging due to interference from other substances and lengthy reaction times. In this research, we proposed a lightweight paper sensor for real-time human serum albumin detection, utilizing imaging and spectroscopy techniques. By combining bromocresol green (BCG) with human serum albumin (HSA), we induced a structural change in BCG, resulting in protonation from C 21 H 14 Br 4 O 5 S to C 21 H 12 Br 4 O 5 2 -S, leading to a blue-green coloration. Subsequently, we applied this reagent to test paper for the reaction, utilized a smartphone camera for image detection, and performed spectrophotometric analyses. Our study presents a convenient, swift, and quantitative approach to measuring HSA concentration, initially accessible through a smartphone camera. Additionally, spectrophotometric analysis ensures precise quantification.
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 17630-17637
A Lightweight Paper Sensor for Real-Time Detection of Human Serum Albumin Based on Imaging and Spectroscopy Methods
Detecting albumin levels quantitatively is challenging due to interference from other substances and lengthy reaction times. In this research, we proposed a lightweight paper sensor for real-time human serum albumin detection, utilizing imaging and spectroscopy techniques. By combining bromocresol green (BCG) with human serum albumin (HSA), we induced a structural change in BCG, resulting in protonation from C 21 H 14 Br 4 O 5 S to C 21 H 12 Br 4 O 5 2 -S, leading to a blue-green coloration. Subsequently, we applied this reagent to test paper for the reaction, utilized a smartphone camera for image detection, and performed spectrophotometric analyses. Our study presents a convenient, swift, and quantitative approach to measuring HSA concentration, initially accessible through a smartphone camera. Additionally, spectrophotometric analysis ensures precise quantification.
- Open Access
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (2) , 1-7
Used High Collimation UV-LEDs With a Miniaturized Optomechanical Device for the Detection of Direct Bilirubin
Invasive blood testing is the most used method for testing bilirubin levels. However, invasive blood testing must be carried out by professionally trained medical staff to avoid the risk of infection. Apart from being present in blood, direct bilirubin is excreted in human urine. Therefore, this study proposed a non-invasive method, using high collimation ultraviolet-light-emitting diodes (HC UV-LEDs) as the light source to design a miniaturized optomechanical device (MOD) for direct bilirubin detection in urine. The designed MOD was used to analyze different concentrations of direct bilirubin using its absorbance spectrum to achieve a non-invasive detection method. The HC UV-LEDs MOD proposed in this study offers the benefits of being non-invasive and providing a quantitative analysis of direct bilirubin.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (2) , 1-7
Open AccessUsed High Collimation UV-LEDs With a Miniaturized Optomechanical Device for the Detection of Direct Bilirubin
Invasive blood testing is the most used method for testing bilirubin levels. However, invasive blood testing must be carried out by professionally trained medical staff to avoid the risk of infection. Apart from being present in blood, direct bilirubin is excreted in human urine. Therefore, this study proposed a non-invasive method, using high collimation ultraviolet-light-emitting diodes (HC UV-LEDs) as the light source to design a miniaturized optomechanical device (MOD) for direct bilirubin detection in urine. The designed MOD was used to analyze different concentrations of direct bilirubin using its absorbance spectrum to achieve a non-invasive detection method. The HC UV-LEDs MOD proposed in this study offers the benefits of being non-invasive and providing a quantitative analysis of direct bilirubin.
- 16 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 30 (3: Flexibl) , 1-7
Detection and Quantification of Urine Albumin Using a Miniature Colorimetric Sensor Consisting of UVC LEDs and CsPbBr 3 Quantum Dot Color Converters
Albumin, a globular protein, is commonly used as an indicator of kidney damage when conducting invasive blood tests and non-invasive urine tests. Moreover, chemical methods that convert ultraviolet light to visible light require additional labeling steps to distinguish albumin from other proteins. In this study, to address labeling issue, a miniature colorimetric sensor (MCS) including the light source using a flip-chip (FC) ultraviolet C light emission diode (UVC-LED) and a green CsPbBr 3 quantum dot (QD) film emitting at 530 nm for converting the transmitting ultraviolet light through bovine serum albumin (BSA) and human serum albumin (HSA) to green fluorescence was developed. The proposed sensor detected BSA and HSA at a concentration range of 0.05 to 4.00 mg/mL, with coefficients of determination(R 2 ) of 0.9822 and 0.9850, limits of detection of 0.61 mg/mL and 0.56 mg/mL, and limits of quantitation of 2.02 mg/mL and 1.86 mg/mL, respectively. Additionally, the portable FC UVC-LEDs MCS offers reduced size and weight while maintaining detection linearity, compared to the conventional spectrometer. The fluorescence detection sensor using UVC-LED emitters and CsPbBr 3 QD film color convertors proposed herein provides an accurate, label-free, instantaneous and non-invasive real-time monitoring and quantification tool for albumin-associated disease diagnosis.
- 16 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 30 (3: Flexibl) , 1-7
Detection and Quantification of Urine Albumin Using a Miniature Colorimetric Sensor Consisting of UVC LEDs and CsPbBr 3 Quantum Dot Color Converters
Albumin, a globular protein, is commonly used as an indicator of kidney damage when conducting invasive blood tests and non-invasive urine tests. Moreover, chemical methods that convert ultraviolet light to visible light require additional labeling steps to distinguish albumin from other proteins. In this study, to address labeling issue, a miniature colorimetric sensor (MCS) including the light source using a flip-chip (FC) ultraviolet C light emission diode (UVC-LED) and a green CsPbBr 3 quantum dot (QD) film emitting at 530 nm for converting the transmitting ultraviolet light through bovine serum albumin (BSA) and human serum albumin (HSA) to green fluorescence was developed. The proposed sensor detected BSA and HSA at a concentration range of 0.05 to 4.00 mg/mL, with coefficients of determination(R 2 ) of 0.9822 and 0.9850, limits of detection of 0.61 mg/mL and 0.56 mg/mL, and limits of quantitation of 2.02 mg/mL and 1.86 mg/mL, respectively. Additionally, the portable FC UVC-LEDs MCS offers reduced size and weight while maintaining detection linearity, compared to the conventional spectrometer. The fluorescence detection sensor using UVC-LED emitters and CsPbBr 3 QD film color convertors proposed herein provides an accurate, label-free, instantaneous and non-invasive real-time monitoring and quantification tool for albumin-associated disease diagnosis.