Using an LED Light Source Coupled With Spectral Image Analysis for Non-Invasive Glucose Detection
Open Access
- 24 April 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (3) , 1-6
Abstract
Glucose monitoring is critical for diabetes patients. However, invasive blood testing carries the risk of infection if wound care is not handled properly and non-invasive glucose testing devices are often bulky and not portable. Therefore, our study proposes the use of white light-emitting diode (LED) bulbs with different color temperatures as a light source. Additionally, ammonium metavanadate and sulfuric acid were used to prepare the detection solution instead of peroxidase to produce color, after which images were captured using a smartphone. The red, green, and blue (RGB) channels were then separated and converted into grayscale images. The average grayscale value changes in the images were analyzed to determine the linear relationship between glucose concentration and grayscale values, thus allowing for non-invasive quantitative glucose testing. When using a 3000K white LED bulb as the light source, the grayscale values of the RGB channels analyzed from the images exhibited a linear relationship with the glucose concentration at a 0.1–10 mM range. The regression equation for the red channel was y = −3.1184x+148.2, with a coefficient of determination (R 2 ) of 0.9165, a limit of detection (LOD) of 2.27 mM, and a limit of quantification (LOQ) of 6.88 mM. The proposed method of using white LED bulbs as a detection light source combined with image analysis can be used to determine whether glucose concentrations in blood, saliva, or tears are higher than normal, providing the advantages of rapid, highly sensitive, and non-invasive testing.Keywords
Funding Information
- National Science and Technology Council (112-2622-E-194-004)
This publication has 56 references indexed in Scilit:
- A novel photoelectrochemical microfluidic chip for multi-index determination of diabetes and its complicationsBiosensors and Bioelectronics, 2022
- Smartphone assisted portable biochip for non-invasive simultaneous monitoring of glucose and insulin towards precise diagnosis of prediabetes/diabetesBiosensors and Bioelectronics, 2022
- Noninvasive blood glucose detection system based on dynamic spectrum and “M+N″ theoryAnalytica Chimica Acta, 2022
- Wearable sweat sensing for prolonged, semicontinuous, and nonobtrusive health monitoringView, 2020
- Fluorescent paper–based sensor based on carbon dots for detection of folic acidAnalytical and Bioanalytical Chemistry, 2020
- Regulation of Glucose Production in the Pathogenesis of Type 2 DiabetesCurrent Diabetes Reports, 2019
- Blood glucose monitoring with smartphone as glucometerElectrophoresis, 2018
- Enzyme‐Based Glucose Sensor: From Invasive to Wearable DeviceAdvanced Healthcare Materials, 2018
- A stretchable and screen-printed electrochemical sensor for glucose determination in human perspirationBiosensors and Bioelectronics, 2017
- Monitoring glycemic control: the importance of self-monitoring of blood glucoseThe American Journal of Medicine, 2005