Huichen Gan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Huichen Gan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Huangqing Xiao
School of Electric Power Engineering, South China University of Technology, Guangzhou, China
6 shared publications Ying Huang
School of Electric Engineering, Zhejiang University, Hangzhou, China
2 shared publicationsChenyi Tang
New Energy Engineering Institute, Powerchina Huadong Engineering Corporation Ltd., Hangzhou, China
1 shared publicationHan Xu
New Energy Engineering Institute, Powerchina Huadong Engineering Corporation Ltd., Hangzhou, China
1 shared publication- Kai Gong
School of Electric Power Engineering, South China University of Technology, Guangzhou, China
1 shared publication Lidong Zhang
China Southern Power Grid Electric Power Research Institute, Guangzhou, China
1 shared publication
Latest Publications
- Open Access
- 22 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 78601-78613
Resonance Stability Analysis Method for Power Systems With High Proportion of Renewable Energy
As inverter-based resources (IBRs) are increasingly integrated into power systems, network resonance instability has become more common in recent years, primarily caused by the interaction between IBR power-electronic controllers and passive network elements. The existing s-domain nodal admittance matrix-based method provides a useful framework for large-scale resonance analysis and can deliver comprehensive modal information. However, when applied to power systems with a high proportion of renewable energy, the physical conditions associated with resonance instability driven by the negative-resistance effect of IBRs are not explicitly incorporated, and singular behavior in the nodal susceptance matrix may lead to misidentification of resonance points. To address these limitations, this paper proposes an improved s-domain nodal admittance matrix-based method. Specifically, the relationship between the negative-resistance effect of IBRs and modal impedance is analyzed to establish a modal-parameter criterion for unstable resonant modes, and the first-stage resonance screening is reformulated using the nodal reactance matrix to avoid singularity-induced misidentification. In addition, a method for establishing the s-domain impedance model of renewable energy stations is presented, and the theoretical basis and implementation procedure of the improved method are detailed. Finally, a modified IEEE 9-bus system is built in PSCAD/EMTDC. Comparing results with the existing method validates the improved method’s effectiveness.
- 22 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 78601-78613
Open AccessResonance Stability Analysis Method for Power Systems With High Proportion of Renewable Energy
As inverter-based resources (IBRs) are increasingly integrated into power systems, network resonance instability has become more common in recent years, primarily caused by the interaction between IBR power-electronic controllers and passive network elements. The existing s-domain nodal admittance matrix-based method provides a useful framework for large-scale resonance analysis and can deliver comprehensive modal information. However, when applied to power systems with a high proportion of renewable energy, the physical conditions associated with resonance instability driven by the negative-resistance effect of IBRs are not explicitly incorporated, and singular behavior in the nodal susceptance matrix may lead to misidentification of resonance points. To address these limitations, this paper proposes an improved s-domain nodal admittance matrix-based method. Specifically, the relationship between the negative-resistance effect of IBRs and modal impedance is analyzed to establish a modal-parameter criterion for unstable resonant modes, and the first-stage resonance screening is reformulated using the nodal reactance matrix to avoid singularity-induced misidentification. In addition, a method for establishing the s-domain impedance model of renewable energy stations is presented, and the theoretical basis and implementation procedure of the improved method are detailed. Finally, a modified IEEE 9-bus system is built in PSCAD/EMTDC. Comparing results with the existing method validates the improved method’s effectiveness.
- Open Access
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 208007-208016
Lightweight Design Approaches of Arm Reactor for MMC-HVdc Offshore Converter Stations
T The lightweight design of key equipment is crucial to achieving cost-effective offshore wind power transmission based on modular multilevel converter based high voltage direct current (MMC-HVDC). This study investigates two innovative lightweight arm reactor schemes for offshore applications: a transformer-integrated arm reactor (TIAR) scheme and a distributed arm reactor (DAR) scheme, with complete parameter design methodologies for both approaches. In the TIAR scheme, a three-winding transformer replaces the conventional dual-winding transformer, thereby simplifying the MMC structure. In the DAR approach, the centralized arm reactor is eliminated, and the arm inductance is distributed across individual SMs, which helps reduce the layout area traditionally occupied by the arm reactor room. Through detailed PSCAD/EMTDC simulations of a pseudo-bipolar MMC-HVDC system integrating offshore wind farms, this study compares its steady-state and transient performance with varies designs. Key findings demonstrate: (i) Under DC bipolar short-circuit faults, both proposed schemes limit the maximum arm current to below 1.2 p.u. without significant SM capacitor voltage collapse; (ii) During converter blocking, the transformer valve-side voltage in lightweight designs exhibits lower magnitudes compared to conventional arm reactor schemes.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 208007-208016
Open AccessLightweight Design Approaches of Arm Reactor for MMC-HVdc Offshore Converter Stations
T The lightweight design of key equipment is crucial to achieving cost-effective offshore wind power transmission based on modular multilevel converter based high voltage direct current (MMC-HVDC). This study investigates two innovative lightweight arm reactor schemes for offshore applications: a transformer-integrated arm reactor (TIAR) scheme and a distributed arm reactor (DAR) scheme, with complete parameter design methodologies for both approaches. In the TIAR scheme, a three-winding transformer replaces the conventional dual-winding transformer, thereby simplifying the MMC structure. In the DAR approach, the centralized arm reactor is eliminated, and the arm inductance is distributed across individual SMs, which helps reduce the layout area traditionally occupied by the arm reactor room. Through detailed PSCAD/EMTDC simulations of a pseudo-bipolar MMC-HVDC system integrating offshore wind farms, this study compares its steady-state and transient performance with varies designs. Key findings demonstrate: (i) Under DC bipolar short-circuit faults, both proposed schemes limit the maximum arm current to below 1.2 p.u. without significant SM capacitor voltage collapse; (ii) During converter blocking, the transformer valve-side voltage in lightweight designs exhibits lower magnitudes compared to conventional arm reactor schemes.
- Open Access
- 14 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 88972-88983
Adaptive LVRT Control Strategy for VSC Based on Hybrid Synchronization Control
In recent years, the problem of large-scale renewables tripping caused by power grid faults has occurred from time to time. By analyzing the power angle and fault current characteristics of the hybrid synchronization control (HSC)-based voltage source converter (VSC), this paper presents an adaptive low-voltage ride-through (LVRT) control strategy for HSC-based VSC. The proposed strategy includes three adaptive control measures: adaptive power angle control, adaptive internal potential control and adaptive virtual impedance control. The adaptive power angle control can keep the power angle equal to its pre-fault value, which greatly improves the transient stability of the system and effectively suppress the fault current. The adaptive internal potential control quantitatively suppresses fault current by adjust voltage reference in the voltage control. The adaptive virtual impedance control is used to suppress pulse currents at the instant of grid voltage dip/recovery. Finally, both theoretical and simulation analyses are conducted to validate the effectiveness of the proposed adaptive LVRT control strategy.
- 14 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 88972-88983
Open AccessAdaptive LVRT Control Strategy for VSC Based on Hybrid Synchronization Control
In recent years, the problem of large-scale renewables tripping caused by power grid faults has occurred from time to time. By analyzing the power angle and fault current characteristics of the hybrid synchronization control (HSC)-based voltage source converter (VSC), this paper presents an adaptive low-voltage ride-through (LVRT) control strategy for HSC-based VSC. The proposed strategy includes three adaptive control measures: adaptive power angle control, adaptive internal potential control and adaptive virtual impedance control. The adaptive power angle control can keep the power angle equal to its pre-fault value, which greatly improves the transient stability of the system and effectively suppress the fault current. The adaptive internal potential control quantitatively suppresses fault current by adjust voltage reference in the voltage control. The adaptive virtual impedance control is used to suppress pulse currents at the instant of grid voltage dip/recovery. Finally, both theoretical and simulation analyses are conducted to validate the effectiveness of the proposed adaptive LVRT control strategy.
- 3 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (3) , 1621-1633
Cost-Efficient Hybrid Converter for Large-Scale Offshore Wind Power Transmission
As offshore wind farms increase in scale and distance, it is crucial to identify more economical and reliable converter technologies for far-offshore wind power (OWP) high voltage direct current transmission system. In this paper, a cost-efficient hybrid converter topology is proposed based on the scheme of diode rectifier unit (DRU) and modular multilevel converter (MMC) in parallel. Compared to the DRU and MMC station-parallel scheme, the proposed hybrid converter scheme eliminates the need for the transformer in DRU and ensures that no harmonics pass through the remaining converter transformer. Furthermore, the required sub-module capacitance of the proposed scheme is smaller, which is conducive to lower costs. The mathematical model of the hybrid converter is developed, and based on this model, the working principle, along with the harmonic transfer characteristics is analyzed. An active power coordination control strategy and a harmonic suppression strategy are proposed. The PSCAD/EMTDC results for a 1000 MW-OWP integration system with the hybrid converter verifies the effectiveness of the proposed scheme. Finally, a comparison with existing schemes and a detailed economic analysis are performed to demonstrate the superior advantages of the proposed scheme.
- 3 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (3) , 1621-1633
Cost-Efficient Hybrid Converter for Large-Scale Offshore Wind Power Transmission
As offshore wind farms increase in scale and distance, it is crucial to identify more economical and reliable converter technologies for far-offshore wind power (OWP) high voltage direct current transmission system. In this paper, a cost-efficient hybrid converter topology is proposed based on the scheme of diode rectifier unit (DRU) and modular multilevel converter (MMC) in parallel. Compared to the DRU and MMC station-parallel scheme, the proposed hybrid converter scheme eliminates the need for the transformer in DRU and ensures that no harmonics pass through the remaining converter transformer. Furthermore, the required sub-module capacitance of the proposed scheme is smaller, which is conducive to lower costs. The mathematical model of the hybrid converter is developed, and based on this model, the working principle, along with the harmonic transfer characteristics is analyzed. An active power coordination control strategy and a harmonic suppression strategy are proposed. The PSCAD/EMTDC results for a 1000 MW-OWP integration system with the hybrid converter verifies the effectiveness of the proposed scheme. Finally, a comparison with existing schemes and a detailed economic analysis are performed to demonstrate the superior advantages of the proposed scheme.
- 19 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5398-5406
Capacitor Voltage Ripple Control Strategy of Lightweight Modular Multilevel Converter for Offshore Wind Power Transmission
In offshore wind power (OWP) projects, converter valves are the largest equipment within offshore converter stations. A low ripple voltage of submodule (SM) capacitors is helpful in reducing the capacitor volume in converter valves, thereby minimizing the volume and weight of offshore converter stations. This paper proposes a comprehensive control strategy for the voltage ripple of SM capacitors in the modular multilevel converter (MMC), capable of eliminating the second-order harmonic in the capacitor voltage. Compared to the conventional circulating current suppression control (CCSC), the proposed control strategy reduces the voltage fluctuation and submodule capacitance by approximately 50%, providing an opportunity for converter volume optimization. Additionally, the RMS arm currents is also reduced to avoid additional loss. Finally, a two-terminal MMC based high voltage direct current (HVDC) model was built in PSCAD/EMTDC to verify the effectiveness and feasibility of the proposed method.
- 19 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5398-5406
Capacitor Voltage Ripple Control Strategy of Lightweight Modular Multilevel Converter for Offshore Wind Power Transmission
In offshore wind power (OWP) projects, converter valves are the largest equipment within offshore converter stations. A low ripple voltage of submodule (SM) capacitors is helpful in reducing the capacitor volume in converter valves, thereby minimizing the volume and weight of offshore converter stations. This paper proposes a comprehensive control strategy for the voltage ripple of SM capacitors in the modular multilevel converter (MMC), capable of eliminating the second-order harmonic in the capacitor voltage. Compared to the conventional circulating current suppression control (CCSC), the proposed control strategy reduces the voltage fluctuation and submodule capacitance by approximately 50%, providing an opportunity for converter volume optimization. Additionally, the RMS arm currents is also reduced to avoid additional loss. Finally, a two-terminal MMC based high voltage direct current (HVDC) model was built in PSCAD/EMTDC to verify the effectiveness and feasibility of the proposed method.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (3) , 1783-1793
Control and Capacity Design of Station-Hybrid HVDC System With DRU and MMC in Parallel for Offshore Wind Power Integration
The station-hybrid HVDC system combining diode rectifier unit (DRU) and modular multilevel converter (MMC) in parallel has garnered significant attention within the field of light-duty HVDC systems. This paper presents a comprehensive investigation into the control and capacity design of this station-hybrid scheme. Firstly, a coordinated power control strategy is presented to provide grid-forming capability and mitigate transmission losses. In addition, a software-based harmonic suppression strategy is introduced. This innovative approach eliminates the need for additional hardware filters in the DRU, streamlining the system while effectively suppressing unwanted harmonics. Moreover, the capacity of the station is meticulously designed to optimize overall system performance. An economic evaluation is conducted to compare the proposed station-hybrid scheme with the conventional compact MMC scheme, shedding light on the economic feasibility and competitiveness of the proposed configuration. Finally, the paper validates the proposed coordinated power control and harmonic suppression strategy through simulations using the PSCAD platform. The results confirm the practicality and effectiveness of these control strategies in real-world applications.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (3) , 1783-1793
Control and Capacity Design of Station-Hybrid HVDC System With DRU and MMC in Parallel for Offshore Wind Power Integration
The station-hybrid HVDC system combining diode rectifier unit (DRU) and modular multilevel converter (MMC) in parallel has garnered significant attention within the field of light-duty HVDC systems. This paper presents a comprehensive investigation into the control and capacity design of this station-hybrid scheme. Firstly, a coordinated power control strategy is presented to provide grid-forming capability and mitigate transmission losses. In addition, a software-based harmonic suppression strategy is introduced. This innovative approach eliminates the need for additional hardware filters in the DRU, streamlining the system while effectively suppressing unwanted harmonics. Moreover, the capacity of the station is meticulously designed to optimize overall system performance. An economic evaluation is conducted to compare the proposed station-hybrid scheme with the conventional compact MMC scheme, shedding light on the economic feasibility and competitiveness of the proposed configuration. Finally, the paper validates the proposed coordinated power control and harmonic suppression strategy through simulations using the PSCAD platform. The results confirm the practicality and effectiveness of these control strategies in real-world applications.