Yang Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yang Yang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Tianling Lyu
Key Laboratory of New Generation Artificial Intelligence Technology and its Interdisciplinary Applications, Ministry of Education, Southeast University, Nanjing, China
2 shared publications - Yan Xi
Shanghai First-Imaging Information Technology Company Ltd., Shanghai, China
2 shared publications - Yang Chen
Southeast University
2 shared publications - Zhan Wu
Laboratory of Image Science and Technology, Southeast University, Nanjing, China
2 shared publications - Dayang Wang
Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, USA
1 shared publication - Dianlin Hu
Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
1 shared publication
Latest Publications
- 1 January 2026
- Published by World Scientific Pub Co Pte Ltd in Functional Materials Letters
- Vol. 19
Two-dimensional reduced graphene oxide/glycolate-Mn hybrids for high-performance lithium ion anodes
The lithium storage property of the anode could be effectively improved by synergizing the merits of transition metal compounds and two-dimensional (2D) reduced graphene oxide (rGO). Herein, we adopted a simple polyol method to synthesize 2D rGO/glycolate-Mn hybrids. Due to the intimate interaction between glycolate-Mn and rGO, the hybrids exhibited exceptional electrochemical performance with a superior specific capacity of 1019.9 mAh g-1 (final cycle capacity) at a current density of 0.5 A g-1 after 800 cycles, as well as superb rate capability of 308.4 mA h g-1 at 5 A g-1.
- 1 January 2026
- Published by World Scientific Pub Co Pte Ltd in Functional Materials Letters
- Vol. 19
Two-dimensional reduced graphene oxide/glycolate-Mn hybrids for high-performance lithium ion anodes
The lithium storage property of the anode could be effectively improved by synergizing the merits of transition metal compounds and two-dimensional (2D) reduced graphene oxide (rGO). Herein, we adopted a simple polyol method to synthesize 2D rGO/glycolate-Mn hybrids. Due to the intimate interaction between glycolate-Mn and rGO, the hybrids exhibited exceptional electrochemical performance with a superior specific capacity of 1019.9 mAh g-1 (final cycle capacity) at a current density of 0.5 A g-1 after 800 cycles, as well as superb rate capability of 308.4 mA h g-1 at 5 A g-1.
- 28 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (5) , 1776-1786
UPMCL-Net: Unsupervised Projection-Domain Multiview Constraint Learning for CBCT Metal Artifact Reduction
Cone-Beam Computed Tomography (CBCT) provides real-time three-dimensional (3D) imaging support for intraoperative navigation. However, high-attenuation metal implants introduce severe metal artifacts in reconstructed CBCT images. These artifacts compromise image quality and therefore may affect diagnostic accuracy. Current CBCT metal artifact reduction (MAR) algorithms overlook the complementary information available across CBCT views, leading to inaccurate projection-domain interpolation and secondary artifacts in the reconstructed images. To tackle these challenges, we propose a novel Unsupervised Projection-domain Multiview Constraint Learning Network (UPMCL-Net), which directly learns from metal-affected data for CBCT MAR without ground truths. In addition, a transformer-based MultiView Consistency Module (MVCM) is constructed to interpolate the projection-domain metal region for cross-view consistency. Finally, a Hybrid Feature Attention Module (HFAM) is designed to adaptively fuse interview and intraview features. Comprehensive experiments conducted on real clinical datasets confirm the performance of UPMCL-Net, showcasing its potential as an efficient, accurate, and reliable approach for CBCT MAR in clinical intraoperative interventions.
- 28 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (5) , 1776-1786
UPMCL-Net: Unsupervised Projection-Domain Multiview Constraint Learning for CBCT Metal Artifact Reduction
Cone-Beam Computed Tomography (CBCT) provides real-time three-dimensional (3D) imaging support for intraoperative navigation. However, high-attenuation metal implants introduce severe metal artifacts in reconstructed CBCT images. These artifacts compromise image quality and therefore may affect diagnostic accuracy. Current CBCT metal artifact reduction (MAR) algorithms overlook the complementary information available across CBCT views, leading to inaccurate projection-domain interpolation and secondary artifacts in the reconstructed images. To tackle these challenges, we propose a novel Unsupervised Projection-domain Multiview Constraint Learning Network (UPMCL-Net), which directly learns from metal-affected data for CBCT MAR without ground truths. In addition, a transformer-based MultiView Consistency Module (MVCM) is constructed to interpolate the projection-domain metal region for cross-view consistency. Finally, a Hybrid Feature Attention Module (HFAM) is designed to adaptively fuse interview and intraview features. Comprehensive experiments conducted on real clinical datasets confirm the performance of UPMCL-Net, showcasing its potential as an efficient, accurate, and reliable approach for CBCT MAR in clinical intraoperative interventions.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Cone-Beam Computed Tomography Limited-Angle Image Reconstruction Using Planning CT-Guided Deep Diffusion Model
For existing image-guided radiation therapy (IGRT) systems, the limited angular range of the cone-beam computed tomography (CBCT) scanning improves the compactness of the system and compatibility between CBCT and linear accelerator (LINAC) configurations. However, the limited-angle CBCT (LA-CBCT) reconstruction under incomplete projection data causes severe artifacts in the reconstructed images, further having a negative impact on the registration accuracy in IGRT. In this article, we propose a planning CT-guided deep diffusion model, termed LARGE-DiffNet, to improve imaging quality and registration accuracy for LA-CBCT image reconstruction. In stark contrast to existing approaches leveraging hand-crafted regularization, such as local smoothness and/or sparsity of the image, LARGE-DiffNet learns the distribution-level prior knowledge to describe the features of ideal CBCT images via a planning CT-guided diffusion model. The proposed LARGE-DiffNet is evaluated on the clinical CBCT dataset, and extensive experimental results demonstrate that the proposed method outperforms the state-of-the-art (SOTA) methods. The proposed LARGE-DiffNet technique has great potential in IGRT.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Cone-Beam Computed Tomography Limited-Angle Image Reconstruction Using Planning CT-Guided Deep Diffusion Model
For existing image-guided radiation therapy (IGRT) systems, the limited angular range of the cone-beam computed tomography (CBCT) scanning improves the compactness of the system and compatibility between CBCT and linear accelerator (LINAC) configurations. However, the limited-angle CBCT (LA-CBCT) reconstruction under incomplete projection data causes severe artifacts in the reconstructed images, further having a negative impact on the registration accuracy in IGRT. In this article, we propose a planning CT-guided deep diffusion model, termed LARGE-DiffNet, to improve imaging quality and registration accuracy for LA-CBCT image reconstruction. In stark contrast to existing approaches leveraging hand-crafted regularization, such as local smoothness and/or sparsity of the image, LARGE-DiffNet learns the distribution-level prior knowledge to describe the features of ideal CBCT images via a planning CT-guided diffusion model. The proposed LARGE-DiffNet is evaluated on the clinical CBCT dataset, and extensive experimental results demonstrate that the proposed method outperforms the state-of-the-art (SOTA) methods. The proposed LARGE-DiffNet technique has great potential in IGRT.
- 18 March 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (12)
Core-shell designed high entropy alloy CoNiFeCuV-C nanoparticles for enhanced microwave absorption
The widespread interest in high entropy alloy nanostructures stems from their potential utilization in a variety of technological and scientific fields. This study presents an innovative approach employing a one-step metal organic chemical vapor deposition to synthesize quinary high entropy alloy (CoNiFeCuV-C) core-shell nanoparticles designed for microwave absorption applications. Superior microwave absorption performance is attained through the optimization of conduction loss via thermal treatment, coupled with the interfacial polarization across the interfaces between CoNiFeCuV cores and C shell. The paraffin composite filled with an optimal 20% content of CoNiFeCuV-C core-shell nanoparticles demonstrates a minimal reflection loss (RLmin) of −51.8 dB at 13.76 GHz, achieving this performance with a thickness of 2.2 mm. Moreover, the absorbing bandwidth spans 7.44 GHz at a thickness of 2.4 mm. The outstanding accomplishments underscore the potential of utilizing CoNiFeCuV-C core-shell nanoparticles as a promising choice for lightweight, effective microwave absorber material.
- 18 March 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (12)
Core-shell designed high entropy alloy CoNiFeCuV-C nanoparticles for enhanced microwave absorption
The widespread interest in high entropy alloy nanostructures stems from their potential utilization in a variety of technological and scientific fields. This study presents an innovative approach employing a one-step metal organic chemical vapor deposition to synthesize quinary high entropy alloy (CoNiFeCuV-C) core-shell nanoparticles designed for microwave absorption applications. Superior microwave absorption performance is attained through the optimization of conduction loss via thermal treatment, coupled with the interfacial polarization across the interfaces between CoNiFeCuV cores and C shell. The paraffin composite filled with an optimal 20% content of CoNiFeCuV-C core-shell nanoparticles demonstrates a minimal reflection loss (RLmin) of −51.8 dB at 13.76 GHz, achieving this performance with a thickness of 2.2 mm. Moreover, the absorbing bandwidth spans 7.44 GHz at a thickness of 2.4 mm. The outstanding accomplishments underscore the potential of utilizing CoNiFeCuV-C core-shell nanoparticles as a promising choice for lightweight, effective microwave absorber material.