Constanze Bongs
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Constanze Bongs has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Abdellah Ghenaim
INSA Strasbourg, CNRS, ICUBE UMR 7357, Strasbourg, France
1 shared publicationAbderahmane Marouf
Université de Strasbourg, CNRS, iCUBE UMR 7357, Strasbourg, France
1 shared publication- Ahmed G. Rahma
Université de Strasbourg, CNRS, iCUBE UMR 7357, Strasbourg, France
1 shared publication - Armin Marko
Bosch Thermotechnik GmbH, 35457 Lollar, Germany
1 shared publication Christian Glück
Bosch Thermotechnik GmbH, 35457 Lollar, Germany
1 shared publication- Clemens Felsmann
Chair of Building Energy Systems and Heat Supply, Technical University of Dresden, 01062 Dresden, Germany
1 shared publication
Latest Publications
- Open Access
- 18 December 2025
- Published by Springer Nature in Journal of Engineering and Applied Science
- Vol. 72 (1) , 254
Two-phase thermosiphon cooling in data centers: a comprehensive review of refrigerants for practical selection
Data centers (DCs) play a crucial role in supporting artificial intelligence (AI), online platforms and cloud services. Currently, there are approximately 5 billion users worldwide, and this number is expected to grow by 5% annually. This surge will result in a substantial increase in energy consumption and will push us to reconsider appropriate energy management strategies. Two-Phase Thermosiphon (TPT) systems provide effective cooling for DCs through the natural circulation driven by gravity and the phase change of refrigerants. This process facilitates efficient heat transfer without the need for moving components, resulting in improved reliability and energy efficiency, which makes them well-suited for medium to high-density power applications. This paper presents a theoretical and practical in-depth review of common refrigerants used in TPT systems and evaluated them in terms of thermal capacity, operating conditions, geometrical design limitations, environmental impact, health and safety considerations, and international regulations. To synthesize the evaluation of the theoretical comparison findings, a decision matrix was developed to assess the overall suitability of selected refrigerants across all criteria. Water ranked highest, achieving an outstanding score of 89 out of 90, followed by methanol, ammonia, and ethanol with 58.5, 56.5, and 56, respectively. Other natural refrigerants such as pentane and 2-methylbutane demonstrated moderate suitability. In contrast, several alternatives received significantly lower scores due to safety concerns or unfavorable environmental characteristics. Based on in-practice comparisons, water exhibits higher thermal conductance, greater heat capacity, and enhanced thermal stability than many refrigerants commonly employed in TPT systems across a range of operating conditions.
- 18 December 2025
- Published by Springer Nature in Journal of Engineering and Applied Science
- Vol. 72 (1) , 254
Open AccessTwo-phase thermosiphon cooling in data centers: a comprehensive review of refrigerants for practical selection
Data centers (DCs) play a crucial role in supporting artificial intelligence (AI), online platforms and cloud services. Currently, there are approximately 5 billion users worldwide, and this number is expected to grow by 5% annually. This surge will result in a substantial increase in energy consumption and will push us to reconsider appropriate energy management strategies. Two-Phase Thermosiphon (TPT) systems provide effective cooling for DCs through the natural circulation driven by gravity and the phase change of refrigerants. This process facilitates efficient heat transfer without the need for moving components, resulting in improved reliability and energy efficiency, which makes them well-suited for medium to high-density power applications. This paper presents a theoretical and practical in-depth review of common refrigerants used in TPT systems and evaluated them in terms of thermal capacity, operating conditions, geometrical design limitations, environmental impact, health and safety considerations, and international regulations. To synthesize the evaluation of the theoretical comparison findings, a decision matrix was developed to assess the overall suitability of selected refrigerants across all criteria. Water ranked highest, achieving an outstanding score of 89 out of 90, followed by methanol, ammonia, and ethanol with 58.5, 56.5, and 56, respectively. Other natural refrigerants such as pentane and 2-methylbutane demonstrated moderate suitability. In contrast, several alternatives received significantly lower scores due to safety concerns or unfavorable environmental characteristics. Based on in-practice comparisons, water exhibits higher thermal conductance, greater heat capacity, and enhanced thermal stability than many refrigerants commonly employed in TPT systems across a range of operating conditions.
- Open Access
Field Trial Evaluation of a Hybrid Heat Pump in an Existing Multi-Family House before and after Renovation
Renovation of existing buildings is fundamental to reduce greenhouse gas emissions of the building sector and to ensure the efficient operation of renewable heating systems. In multi-family houses, the suitability of heat pumps is limited by high required temperatures for the hot water preparation, which can be mitigated by hybrid heat pump systems. In this study, the energetic performance of a hybrid heat pump in a multi-family house, built in 1964, is investigated based on field data before and after a renovation. Multiple months are measured and mapped to a full year period. The combination of different renovation measures in the heating system and building envelope is rated w.r.t. their ecological and economical impact by taking into account the actual investment costs. The evaluation shows that the installation of a hybrid heat pump can achieve an accumulated greenhouse gas emissions reduction of 45%, which is similar to a building renovation to a new-build standard, which reduces the space heating demand by up to 62%. Nevertheless, only a combination of both measures can substantially reduce the emissions, which in this case are 81% lower compared to a gas boiler in 1990, which is still below the German climate target for 2040. Due to the low investment costs of a hybrid heat pump system, tenants are more likely to profit from a renting costs reduction, while a building renovation is especially economically beneficial at high energy prices. The results therefore emphasize that the insulation level should be selected carefully, as heat pumps already prepare space heating efficiently and that the heat pump must be able to support the hot water preparation to reach high emission reduction targets.
Open AccessField Trial Evaluation of a Hybrid Heat Pump in an Existing Multi-Family House before and after Renovation
Renovation of existing buildings is fundamental to reduce greenhouse gas emissions of the building sector and to ensure the efficient operation of renewable heating systems. In multi-family houses, the suitability of heat pumps is limited by high required temperatures for the hot water preparation, which can be mitigated by hybrid heat pump systems. In this study, the energetic performance of a hybrid heat pump in a multi-family house, built in 1964, is investigated based on field data before and after a renovation. Multiple months are measured and mapped to a full year period. The combination of different renovation measures in the heating system and building envelope is rated w.r.t. their ecological and economical impact by taking into account the actual investment costs. The evaluation shows that the installation of a hybrid heat pump can achieve an accumulated greenhouse gas emissions reduction of 45%, which is similar to a building renovation to a new-build standard, which reduces the space heating demand by up to 62%. Nevertheless, only a combination of both measures can substantially reduce the emissions, which in this case are 81% lower compared to a gas boiler in 1990, which is still below the German climate target for 2040. Due to the low investment costs of a hybrid heat pump system, tenants are more likely to profit from a renting costs reduction, while a building renovation is especially economically beneficial at high energy prices. The results therefore emphasize that the insulation level should be selected carefully, as heat pumps already prepare space heating efficiently and that the heat pump must be able to support the hot water preparation to reach high emission reduction targets.