Pedram Yazdanbakhsh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pedram Yazdanbakhsh has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Marcus J. Couch
Translational Medicine Program, The Hospital for Sick Children, Toronto, ON, Canada; Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
5 shared publications - Kyle M. Gilbert
Centre for Functional and Metabolic Mapping, Western University, London, Ontario, CANADA
4 shared publications - David A. Rudko
McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital Montreal Quebec Canada
3 shared publications - Alexandre D'AStous
NeuroPoly Lab Institute of Biomedical Engineering, Polytechnique Montréal, Quebec Canada
2 shared publications - Daniel Papp
NeuroPoly Lab, Department of Electrical Engineering Polytechnique Montreal Montreal Quebec Canada
2 shared publications - Eva Alonso-Ortiz
NeuroPoly Lab, Institute of Biomedical Engineering Polytechnique Montréal Montréal Quebec Canada
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 15-22
A Birdcage Volume Transmit Coil and 8 Channel Receive Array for Marmoset Brain Imaging at 7T
Objective: To design and fabricate a band-pass birdcage volume resonator and eight channel, conformal receive array coil for MRI of both awake and anesthetized marmoset brain at 7T. The coil is compatible with a whole body 7T clinical MRI scanner running in single channel transmit (sTx) mode. Methods: The marmoset head coil included a shielded, band-pass birdcage transmit coil with 24 legs, as well as 8 overlapped receive elements. Electromagnetic (EM) field simulation was performed for the 24 leg band pass birdcage Tx coil to calculate the B1+ efficiency. The efficacy of both transmit and receive coil designs were evaluated by measuring standard coil performance metrics. This was done while imaging a marmoset head phantom, as well as by acquiring in vivo, anesthetized and awake marmoset images. Results: The transmit coil along with the optimized receive array produced high resolution (0.8 mm isotropic for EPI images; 0.36 mm isotropic for structural images) and high SNR (between 50 and 80) images of the marmoset brain. The simulated B1+ efficiency of the birdcage at the center of the phantom was 2.6 µT/sqrt (W). Conclusion and significance: A shielded, band-pass birdcage transmit coil was designed and fabricated for marmoset brain imaging at 7T. An 8-channel receive array consisting of eight overlapped loops, covering the whole brain of the marmoset, was also constructed and applied for signal reception. The system successfully allowed scanning of both young and older marmosets. It is well-suited for longitudinal studies of marmoset brain structure. The coil advantageously allows the study of neurodevelopment and primate brain function.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 15-22
Open AccessA Birdcage Volume Transmit Coil and 8 Channel Receive Array for Marmoset Brain Imaging at 7T
Objective: To design and fabricate a band-pass birdcage volume resonator and eight channel, conformal receive array coil for MRI of both awake and anesthetized marmoset brain at 7T. The coil is compatible with a whole body 7T clinical MRI scanner running in single channel transmit (sTx) mode. Methods: The marmoset head coil included a shielded, band-pass birdcage transmit coil with 24 legs, as well as 8 overlapped receive elements. Electromagnetic (EM) field simulation was performed for the 24 leg band pass birdcage Tx coil to calculate the B1+ efficiency. The efficacy of both transmit and receive coil designs were evaluated by measuring standard coil performance metrics. This was done while imaging a marmoset head phantom, as well as by acquiring in vivo, anesthetized and awake marmoset images. Results: The transmit coil along with the optimized receive array produced high resolution (0.8 mm isotropic for EPI images; 0.36 mm isotropic for structural images) and high SNR (between 50 and 80) images of the marmoset brain. The simulated B1+ efficiency of the birdcage at the center of the phantom was 2.6 µT/sqrt (W). Conclusion and significance: A shielded, band-pass birdcage transmit coil was designed and fabricated for marmoset brain imaging at 7T. An 8-channel receive array consisting of eight overlapped loops, covering the whole brain of the marmoset, was also constructed and applied for signal reception. The system successfully allowed scanning of both young and older marmosets. It is well-suited for longitudinal studies of marmoset brain structure. The coil advantageously allows the study of neurodevelopment and primate brain function.
- Open Access
- 5 August 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (6) , 2771-2784
A size‐adaptive RF coil for MRI of the pediatric human brain at 7 T
Purpose: The purpose of this work was to design and build a size‐adaptive pediatric RF head coil for 7 T neuroimaging. The coil can be safely applied for imaging children 4–9 years old.Methods: The pediatric head coil incorporates eight, transmit dipole elements for operation in parallel transmit (pTx) mode. The receive architecture is comprised of a 32‐channel conformal, size‐adaptive receive array. Receive elements were arranged into five sections of a mechanically adjustable 3D printed head former, allowing adjustment of the receive array according to child head size. The transmit coil was carefully simulated to calculate specific absorption rate (SAR) and B1+ efficiency. Coil performance was then evaluated with a pediatric head phantom at both the largest and smallest dimensions of the receive former. In vivo imaging was carried out in 3 pediatric subjects (aged 5, 6, and 9 years old) to acquire B1+ field maps and anatomical MP2RAGE images.Results: A comparison of simulated and experimental B1+ performance in the pediatric head phantom was used to validate SAR models and to demonstrate that the coil was safe for pediatric imaging. The SNR performance in the pediatric phantom was improved by adjusting the position of the receive array to the smallest possible position. The in vivo B1+ efficiency agreed with expectations, and the coil provided precise anatomical images of the brain.Conclusions: The proposed size‐adaptive coil enables safe, high‐quality imaging of children at 7 T, with a range of ages and head sizes. Accurate SAR modeling enabled imaging using both combined circularly polarized and dynamic pTx modes.
- 5 August 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (6) , 2771-2784
Open AccessA size‐adaptive RF coil for MRI of the pediatric human brain at 7 T
Purpose: The purpose of this work was to design and build a size‐adaptive pediatric RF head coil for 7 T neuroimaging. The coil can be safely applied for imaging children 4–9 years old.Methods: The pediatric head coil incorporates eight, transmit dipole elements for operation in parallel transmit (pTx) mode. The receive architecture is comprised of a 32‐channel conformal, size‐adaptive receive array. Receive elements were arranged into five sections of a mechanically adjustable 3D printed head former, allowing adjustment of the receive array according to child head size. The transmit coil was carefully simulated to calculate specific absorption rate (SAR) and B1+ efficiency. Coil performance was then evaluated with a pediatric head phantom at both the largest and smallest dimensions of the receive former. In vivo imaging was carried out in 3 pediatric subjects (aged 5, 6, and 9 years old) to acquire B1+ field maps and anatomical MP2RAGE images.Results: A comparison of simulated and experimental B1+ performance in the pediatric head phantom was used to validate SAR models and to demonstrate that the coil was safe for pediatric imaging. The SNR performance in the pediatric phantom was improved by adjusting the position of the receive array to the smallest possible position. The in vivo B1+ efficiency agreed with expectations, and the coil provided precise anatomical images of the brain.Conclusions: The proposed size‐adaptive coil enables safe, high‐quality imaging of children at 7 T, with a range of ages and head sizes. Accurate SAR modeling enabled imaging using both combined circularly polarized and dynamic pTx modes.
- Open Access
- 13 August 2024
- Published by Wiley in Magnetic Resonance in Medicine
RF shimming in the cervical spinal cord at 7 T
Purpose: Advancing the development of 7 T MRI for spinal cord imaging is crucial for the enhanced diagnosis and monitoring of various neurodegenerative diseases and traumas. However, a significant challenge at this field strength is the transmit field inhomogeneity. Such inhomogeneity is particularly problematic for imaging the small, deep anatomical structures of the cervical spinal cord, as it can cause uneven signal intensity and elevate the local specific absorption ratio, compromising image quality. This multisite study explores several RF shimming techniques in the cervical spinal cord.Methods: Data were collected from 5 participants between two 7 T sites with a custom 8Tx/20Rx parallel transmission coil. We explored two radiofrequency (RF) shimming approaches from an MRI vendor and four from an open‐source toolbox, showcasing their ability to enhance transmit field and signal homogeneity along the cervical spinal cord.Results: The circularly polarized (CP), coefficient of variation (CoV), and specific absorption rate (SAR) efficiency shim modes showed the highest B1+ efficiency, and the vendor‐based “patient” and “volume” modes showed the lowest B1+ efficiency. The coefficient of variation method produced the highest CSF/spinal cord contrast on T2*‐weighted scans (ratio of 1.27 ± 0.03), and the lowest variation of that contrast along the superior–inferior axis.Conclusion: The study's findings highlight the potential of RF shimming to advance 7 T MRI's clinical utility for central nervous system imaging by enabling more homogenous and efficient spinal cord imaging. Additionally, the research incorporates a reproducible Jupyter Notebook, enhancing the study's transparency and facilitating peer verification.
- 13 August 2024
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessRF shimming in the cervical spinal cord at 7 T
Purpose: Advancing the development of 7 T MRI for spinal cord imaging is crucial for the enhanced diagnosis and monitoring of various neurodegenerative diseases and traumas. However, a significant challenge at this field strength is the transmit field inhomogeneity. Such inhomogeneity is particularly problematic for imaging the small, deep anatomical structures of the cervical spinal cord, as it can cause uneven signal intensity and elevate the local specific absorption ratio, compromising image quality. This multisite study explores several RF shimming techniques in the cervical spinal cord.Methods: Data were collected from 5 participants between two 7 T sites with a custom 8Tx/20Rx parallel transmission coil. We explored two radiofrequency (RF) shimming approaches from an MRI vendor and four from an open‐source toolbox, showcasing their ability to enhance transmit field and signal homogeneity along the cervical spinal cord.Results: The circularly polarized (CP), coefficient of variation (CoV), and specific absorption rate (SAR) efficiency shim modes showed the highest B1+ efficiency, and the vendor‐based “patient” and “volume” modes showed the lowest B1+ efficiency. The coefficient of variation method produced the highest CSF/spinal cord contrast on T2*‐weighted scans (ratio of 1.27 ± 0.03), and the lowest variation of that contrast along the superior–inferior axis.Conclusion: The study's findings highlight the potential of RF shimming to advance 7 T MRI's clinical utility for central nervous system imaging by enabling more homogenous and efficient spinal cord imaging. Additionally, the research incorporates a reproducible Jupyter Notebook, enhancing the study's transparency and facilitating peer verification.
- Open Access
- 4 April 2024
- Published by Centre de Recherche de l'Institut Universitaire de Geriatrie de Montreal
- p. 25
Analysis code for the paper “RF shimming in the cervical spinal cord at 7T”
Data was collected from five participants between two 7T sites with a custom 8Tx/20Rx parallel transmission (pTx) coil. We explored two RF shimming approaches from an MRI vendor and four from an open-source toolbox, showcasing their ability to enhance transmit field and signal homogeneity along the cervical spinal cord.
- 4 April 2024
- Published by Centre de Recherche de l'Institut Universitaire de Geriatrie de Montreal
- p. 25
Open AccessAnalysis code for the paper “RF shimming in the cervical spinal cord at 7T”
Data was collected from five participants between two 7T sites with a custom 8Tx/20Rx parallel transmission (pTx) coil. We explored two RF shimming approaches from an MRI vendor and four from an open-source toolbox, showcasing their ability to enhance transmit field and signal homogeneity along the cervical spinal cord.
- 21 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2537-2544
An 8-Channel Transceiver Coil for Carotid Artery Imaging at 7T Using an Optimized Shield Design
Objective: To design and fabricate a transmit/receive (T/R) radiofrequency (RF) coil array for MRI of the carotid arteries at 7 T with optimal shielding to improve transmit performance in parallel transmit (pTx) mode. Methods: The carotid coil included 8 total RF elements, with left and right subarrays, each consisting of 4 overlapping loops with RF shields. Electromagnetic (EM) simulations were performed to optimize and improve the transmit performance of the array by determining the optimal distance between the RF shield and each subarray. EM simulations were further used to calculate local specific absorption rate (SAR) matrices. Based on the SAR matrices, virtual observation points (VOPs) were applied to ensure safety during parallel transmission. The efficacy of the coil design was evaluated by measuring coil performance metrics when imaging a phantom and by acquiring in-vivo images. Results: The optimal distance between the RF shield and each subarray was determined to be 45 mm. This resulted in a maximum B 1 + efficiency of 1.23 μT/ $\surd W$ in the carotid arteries and a peak, 10-g-average SAR per Watt of 0.86 kg -1 when transmitting in the nominal CP + mode. Optimizing the RF shield resulted in up to 37% improvement in B 1 + efficiency and 14% improvement in SAR efficiency compared to an unshielded design. Conclusion and significance: Optimizing the distance between the RF shield and coil array provided significant improvement in the transmit characteristics of the bilateral carotid coil. The bilateral coil topology provides a compelling platform for imaging the carotid arteries with high field MRI.
- 21 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2537-2544
An 8-Channel Transceiver Coil for Carotid Artery Imaging at 7T Using an Optimized Shield Design
Objective: To design and fabricate a transmit/receive (T/R) radiofrequency (RF) coil array for MRI of the carotid arteries at 7 T with optimal shielding to improve transmit performance in parallel transmit (pTx) mode. Methods: The carotid coil included 8 total RF elements, with left and right subarrays, each consisting of 4 overlapping loops with RF shields. Electromagnetic (EM) simulations were performed to optimize and improve the transmit performance of the array by determining the optimal distance between the RF shield and each subarray. EM simulations were further used to calculate local specific absorption rate (SAR) matrices. Based on the SAR matrices, virtual observation points (VOPs) were applied to ensure safety during parallel transmission. The efficacy of the coil design was evaluated by measuring coil performance metrics when imaging a phantom and by acquiring in-vivo images. Results: The optimal distance between the RF shield and each subarray was determined to be 45 mm. This resulted in a maximum B 1 + efficiency of 1.23 μT/ $\surd W$ in the carotid arteries and a peak, 10-g-average SAR per Watt of 0.86 kg -1 when transmitting in the nominal CP + mode. Optimizing the RF shield resulted in up to 37% improvement in B 1 + efficiency and 14% improvement in SAR efficiency compared to an unshielded design. Conclusion and significance: Optimizing the distance between the RF shield and coil array provided significant improvement in the transmit characteristics of the bilateral carotid coil. The bilateral coil topology provides a compelling platform for imaging the carotid arteries with high field MRI.