A size‐adaptive RF coil for MRI of the pediatric human brain at 7 T
Open Access
- 5 August 2025
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (6) , 2771-2784
Abstract
Purpose: The purpose of this work was to design and build a size‐adaptive pediatric RF head coil for 7 T neuroimaging. The coil can be safely applied for imaging children 4–9 years old.Methods: The pediatric head coil incorporates eight, transmit dipole elements for operation in parallel transmit (pTx) mode. The receive architecture is comprised of a 32‐channel conformal, size‐adaptive receive array. Receive elements were arranged into five sections of a mechanically adjustable 3D printed head former, allowing adjustment of the receive array according to child head size. The transmit coil was carefully simulated to calculate specific absorption rate (SAR) and B1+ efficiency. Coil performance was then evaluated with a pediatric head phantom at both the largest and smallest dimensions of the receive former. In vivo imaging was carried out in 3 pediatric subjects (aged 5, 6, and 9 years old) to acquire B1+ field maps and anatomical MP2RAGE images.Results: A comparison of simulated and experimental B1+ performance in the pediatric head phantom was used to validate SAR models and to demonstrate that the coil was safe for pediatric imaging. The SNR performance in the pediatric phantom was improved by adjusting the position of the receive array to the smallest possible position. The in vivo B1+ efficiency agreed with expectations, and the coil provided precise anatomical images of the brain.Conclusions: The proposed size‐adaptive coil enables safe, high‐quality imaging of children at 7 T, with a range of ages and head sizes. Accurate SAR modeling enabled imaging using both combined circularly polarized and dynamic pTx modes.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (NSERC‐RGPIN‐2018‐05047)
- Azrieli Foundation
- Fondation Brain Canada
- Nature et technologies
This publication has 37 references indexed in Scilit:
- 7T MR SafetyJournal of Magnetic Resonance Imaging, 2020
- Utility of real-time field control in T2 *-Weighted head MRI at 7TMagnetic Resonance in Medicine, 2015
- A field camera for MR sequence monitoring and system analysisMagnetic Resonance in Medicine, 2015
- Motion artifacts in MRI: A complex problem with many partial solutionsJournal of Magnetic Resonance Imaging, 2015
- Real‐time feedback for spatiotemporal field stabilization in MR systemsMagnetic Resonance in Medicine, 2014
- MRI at 7 tesla and above: Demonstrated and potential capabilitiesJournal of Magnetic Resonance Imaging, 2014
- Size‐optimized 32‐channel brain arrays for 3 T pediatric imagingMagnetic Resonance in Medicine, 2011
- Local specific absorption rate control for parallel transmission by virtual observation pointsMagnetic Resonance in Medicine, 2011
- Spatiotemporal magnetic field monitoring for MRMagnetic Resonance in Medicine, 2008
- Image reconstruction in SNR units: A general method for SNR measurement†Magnetic Resonance in Medicine, 2005