H. Asadollahi Yazdi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
H. Asadollahi Yazdi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Abhinav Kumar
Department of Mathematical Sciences, Saveetha School of Engineering, SIMATS, Chennai, India
1 shared publication - Ameer H. Al-Rubaye
Department of Petroleum Engineering Al‐Kitab University Altun Kupri Iraq
1 shared publication Hanin E. Yeslam
Department of Restorative Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
1 shared publication- Karrar Hatif Mohamed
Scientific Research Center, Al-Ayen University, Thi-Qar, 64001, Iraq
1 shared publication - Manal Abdulwahid Abbood
Division of Medical and Industrial Materials Science, Department of Applied Sciences, University of Technology, Al Senaha Street, Baghdad, Iraq
1 shared publication - Shahabe Saquib Abullais
Department of Periodontics and Community Dental Science, College of Dentistry, King Khalid University, Abha, Saudi Arabia
1 shared publication
Latest Publications
- 25 March 2025
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
DESIGN AND FABRICATION OF A NEW FGM IMPLANT
Nowadays, there is a growing need for using functionally graded materials (FGM) for using in bio-medical application. This need is prominent especially for the effect of gradient structures and in implant applications. To optimize both mechanical and biocompatibilities properties or change bio reactivity in each region, powder metallurgy technique is used in this study to fabricate titanium/hydroxyapatite (Ti/HAP) and other FGM implants with the concentration changed gradually in the longitudinal direction of cylindrical shapes. Concentration gradient was formed by packing dry powders into mold or sedimentation in solvent liquid processes. For the sintering process, three spark plasma sintering (SPS), high-frequency induction heating and electric furnace heating techniques were used to sinter the materials. During the fabrication of Ti/HAP FGMs and due to the stress relaxation in the implanted regions of bones, Brinell hardness decreased gradually from Ti part to HAP part. The results showed that the tissue reaction occurred gradiently in response to the graded structure of the FGM, which implies the possibility of controlling the tissue response through the gradient function of the FGM.
- 25 March 2025
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
DESIGN AND FABRICATION OF A NEW FGM IMPLANT
Nowadays, there is a growing need for using functionally graded materials (FGM) for using in bio-medical application. This need is prominent especially for the effect of gradient structures and in implant applications. To optimize both mechanical and biocompatibilities properties or change bio reactivity in each region, powder metallurgy technique is used in this study to fabricate titanium/hydroxyapatite (Ti/HAP) and other FGM implants with the concentration changed gradually in the longitudinal direction of cylindrical shapes. Concentration gradient was formed by packing dry powders into mold or sedimentation in solvent liquid processes. For the sintering process, three spark plasma sintering (SPS), high-frequency induction heating and electric furnace heating techniques were used to sinter the materials. During the fabrication of Ti/HAP FGMs and due to the stress relaxation in the implanted regions of bones, Brinell hardness decreased gradually from Ti part to HAP part. The results showed that the tissue reaction occurred gradiently in response to the graded structure of the FGM, which implies the possibility of controlling the tissue response through the gradient function of the FGM.
- 25 March 2024
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 31 (11)
EVOLUTION OF WEAR AND CORROSION RESISTANCE OF Bi ALLOY-LAMINATED Al/TiO2 COMPOSITE STRIPS FABRICATED VIA APB PROCESS
In this study, Bi alloy AA1100/TiO2/AA5083 composites were produced by accumulative press bonding (APB) for the first time. In the first step, two bars of aluminum alloys 1100 and 5083 with 5[ ]wt.% of uniformly scattered TiO2 particles were stacked together and pressed with a 50% reduction ratio. Then, this process was continued up to six steps. Corrosion properties of composites were studied by potential dynamic polarization and electrochemical impedance spectroscopy measurement in 3.5[ ]wt.% NaCl solution. So, in this investigation and as its novelty, a considerable improvement was revealed in the main electrochemical parameters as a result of enhancing the influence of APB steps and the inert character of the particles. Moreover, using the wear test, the wear resistance of these bi alloy composites has been studied vs the APB steps. Also, the wear and electrochemical experiments showed that corrosion and wear resistance of samples were improved by the APB steps by 70% and 34%, respectively.
- 25 March 2024
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 31 (11)
EVOLUTION OF WEAR AND CORROSION RESISTANCE OF Bi ALLOY-LAMINATED Al/TiO2 COMPOSITE STRIPS FABRICATED VIA APB PROCESS
In this study, Bi alloy AA1100/TiO2/AA5083 composites were produced by accumulative press bonding (APB) for the first time. In the first step, two bars of aluminum alloys 1100 and 5083 with 5[ ]wt.% of uniformly scattered TiO2 particles were stacked together and pressed with a 50% reduction ratio. Then, this process was continued up to six steps. Corrosion properties of composites were studied by potential dynamic polarization and electrochemical impedance spectroscopy measurement in 3.5[ ]wt.% NaCl solution. So, in this investigation and as its novelty, a considerable improvement was revealed in the main electrochemical parameters as a result of enhancing the influence of APB steps and the inert character of the particles. Moreover, using the wear test, the wear resistance of these bi alloy composites has been studied vs the APB steps. Also, the wear and electrochemical experiments showed that corrosion and wear resistance of samples were improved by the APB steps by 70% and 34%, respectively.