Микола Володимирович Бабенко
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Микола Володимирович Бабенко has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Олександр Олександрович Азюковський
Національний технічний університет «Дніпровська політехніка
7 shared publications - Yurii Papaika
Dnipro University of Technology, Dmytra Yavornytskoho Ave 19, Dnipro, Ukraine; Dnipropetrovsk Research Institute of Judicial Examination, Sicheslavska Naberezhna St, 17, Of. 801, Dnipro, Ukraine
3 shared publications - Oleksandr Pashchenko
Національний технічний університет «Дніпровська політехніка
2 shared publications - Станіслав Кирилович Шихов
Національний технічний університет «Дніпровська політехніка
2 shared publications H. H Pivniak
1 shared publication- Jamil Haddad
Department of Mechanical Engineering, Faculty of Engineering Technology, Al-Balqa Applied University, Amman, Jordan
1 shared publication
Latest Publications
- 28 February 2026
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 1,p. 50-57
Development and evaluation of combined methods for cleaning paraffin wax deposits in pipelines oil and gas industry
Purpose. To develop and assess the efficacy of combined mechanical, chemical, and thermal methods for removing paraffin wax deposits from extended pipelines with circular cross-sections and drilling systems, addressing operational challenges in the oil and gas industry. Methodology. A multidisciplinary approach was employed, integrating laboratory experiments, numerical modeling, and field trial validation. Laboratory tests used steel pipeline models and production tubing to simulate paraffin deposition under varying temperature (20–60 °C) and pressure (10–50 MPa) conditions. Deposit composition was analyzed via gas chromatography and mass spectrometry, while cleaning methods – mechanical pigging, chemical solvents, and thermal heating – were evaluated for removal efficiency. Computational fluid dynamics (CFD) simulations using ANSYS Fluent modeled deposition and cleaning dynamics, focusing on flow velocity, turbulence, and pipeline geometry. Field trials, where feasible, validated laboratory results on operational pipelines and drilling rigs. Findings. Combined methods achieved up to 90 % removal efficiency, with hybrid approaches (chemical solvents and mechanical pigging) outperforming single methods in high-paraffin oils and drilling tubing. Deposit thickness (2–5 mm) correlated with temperature gradients, with critical deposition zones identified in pipeline bends and drilling inlets. Mechanical methods were cost-effective (50–100 USD/m) but less efficient in smaller-diameter tubing, while thermal methods were energy-intensive (20–50 MJ/m). Recommendations include hybrid cleaning protocols and IoT-based monitoring for proactive maintenance. Originality. This study introduces a novel framework integrating mechanical, chemical, and thermal methods tailored to circular pipelines and drilling systems, with CFD models quantifying deposition dynamics. New insights into the interplay of pipeline geometry and drilling conditions enhance cleaning optimization. Practical value. The proposed methods reduce downtime by 20 % and maintenance costs by 15–25 %, with IoT integration enabling predictive maintenance. These solutions are applicable to diverse oil compositions and drilling environments, improving operational efficiency and environmental sustainability.
- 28 February 2026
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 1,p. 50-57
Development and evaluation of combined methods for cleaning paraffin wax deposits in pipelines oil and gas industry
Purpose. To develop and assess the efficacy of combined mechanical, chemical, and thermal methods for removing paraffin wax deposits from extended pipelines with circular cross-sections and drilling systems, addressing operational challenges in the oil and gas industry. Methodology. A multidisciplinary approach was employed, integrating laboratory experiments, numerical modeling, and field trial validation. Laboratory tests used steel pipeline models and production tubing to simulate paraffin deposition under varying temperature (20–60 °C) and pressure (10–50 MPa) conditions. Deposit composition was analyzed via gas chromatography and mass spectrometry, while cleaning methods – mechanical pigging, chemical solvents, and thermal heating – were evaluated for removal efficiency. Computational fluid dynamics (CFD) simulations using ANSYS Fluent modeled deposition and cleaning dynamics, focusing on flow velocity, turbulence, and pipeline geometry. Field trials, where feasible, validated laboratory results on operational pipelines and drilling rigs. Findings. Combined methods achieved up to 90 % removal efficiency, with hybrid approaches (chemical solvents and mechanical pigging) outperforming single methods in high-paraffin oils and drilling tubing. Deposit thickness (2–5 mm) correlated with temperature gradients, with critical deposition zones identified in pipeline bends and drilling inlets. Mechanical methods were cost-effective (50–100 USD/m) but less efficient in smaller-diameter tubing, while thermal methods were energy-intensive (20–50 MJ/m). Recommendations include hybrid cleaning protocols and IoT-based monitoring for proactive maintenance. Originality. This study introduces a novel framework integrating mechanical, chemical, and thermal methods tailored to circular pipelines and drilling systems, with CFD models quantifying deposition dynamics. New insights into the interplay of pipeline geometry and drilling conditions enhance cleaning optimization. Practical value. The proposed methods reduce downtime by 20 % and maintenance costs by 15–25 %, with IoT integration enabling predictive maintenance. These solutions are applicable to diverse oil compositions and drilling environments, improving operational efficiency and environmental sustainability.
- Open Access
- 16 December 2025
- Published by Zhytomyr Polytechnic State University in Технічна інженерія
- No. 2(96),p. 322-330
Неруйнівні методи оцінки впливу газогідратів на міцність магістральних трубопроводів
У статті здійснено аналіз неруйнівних методів оцінювання впливу газогідратоутворення на міцність сталевих трубопроводів, що експлуатуються в умовах високого тиску та низьких температур, характерних для об’єктів газотранспортної інфраструктури. Особливу увагу приділено проблемі формування гідратних включень, які розглядаються як один із ключових чинників деградації механічних властивостей трубопровідного матеріалу, що своєю чергою може призводити до утворення гідратних пробок та створення передумов до аварійних ситуацій. У межах дослідження запропоновано комплексний підхід до технічної діагностики стану трубопроводів, що передбачає інтегроване застосування сучасних неруйнівних методів контролю, зокрема ультразвукових, магнітних та акустичних. Наведено оцінку ефективності зазначених методів для виявлення внутрішніх дефектів, мікротріщин, структурних неоднорідностей матеріалу, а також ділянок із підвищеним ризиком утворення гідратів. Детально охарактеризовано технічні параметри кожного методу, їхню діагностичну здатність та доцільність застосування в реальних експлуатаційних умовах. На підставі аналізу результатів досліджень та чисельного моделювання встановлено вплив гідратних включень на зміну напружено-деформованого стану трубопровідної сталі. Виявлено, що наявність газогідратів може спричиняти істотне зниження границі плинності та ударної в’язкості матеріалу, що зумовлює зростання ймовірності крихкого руйнування трубопроводу під час експлуатаційних навантажень. Розроблено рекомендації щодо впровадження неруйнівного контролю як ефективного інструменту для прогнозування залишкового ресурсу трубопровідних систем, своєчасного виявлення потенційно небезпечних зон та запобігання техногенним аваріям. Одержані результати можуть бути використані для оптимізації систем моніторингу стану об’єктів газотранспортної мережі з метою підвищення їхньої надійності, безпеки експлуатації та ефективності технічного обслуговування.
- 16 December 2025
- Published by Zhytomyr Polytechnic State University in Технічна інженерія
- No. 2(96),p. 322-330
Open AccessНеруйнівні методи оцінки впливу газогідратів на міцність магістральних трубопроводів
У статті здійснено аналіз неруйнівних методів оцінювання впливу газогідратоутворення на міцність сталевих трубопроводів, що експлуатуються в умовах високого тиску та низьких температур, характерних для об’єктів газотранспортної інфраструктури. Особливу увагу приділено проблемі формування гідратних включень, які розглядаються як один із ключових чинників деградації механічних властивостей трубопровідного матеріалу, що своєю чергою може призводити до утворення гідратних пробок та створення передумов до аварійних ситуацій. У межах дослідження запропоновано комплексний підхід до технічної діагностики стану трубопроводів, що передбачає інтегроване застосування сучасних неруйнівних методів контролю, зокрема ультразвукових, магнітних та акустичних. Наведено оцінку ефективності зазначених методів для виявлення внутрішніх дефектів, мікротріщин, структурних неоднорідностей матеріалу, а також ділянок із підвищеним ризиком утворення гідратів. Детально охарактеризовано технічні параметри кожного методу, їхню діагностичну здатність та доцільність застосування в реальних експлуатаційних умовах. На підставі аналізу результатів досліджень та чисельного моделювання встановлено вплив гідратних включень на зміну напружено-деформованого стану трубопровідної сталі. Виявлено, що наявність газогідратів може спричиняти істотне зниження границі плинності та ударної в’язкості матеріалу, що зумовлює зростання ймовірності крихкого руйнування трубопроводу під час експлуатаційних навантажень. Розроблено рекомендації щодо впровадження неруйнівного контролю як ефективного інструменту для прогнозування залишкового ресурсу трубопровідних систем, своєчасного виявлення потенційно небезпечних зон та запобігання техногенним аваріям. Одержані результати можуть бути використані для оптимізації систем моніторингу стану об’єктів газотранспортної мережі з метою підвищення їхньої надійності, безпеки експлуатації та ефективності технічного обслуговування.
- Open Access
- 9 December 2025
- Published by Publishing House Helvetica (Publications) in Електротехнічні та інформаційні системи
- No. 108,p. 3-7
ВИБІР ОПТИМАЛЬНОЇ СТРУКТУРИ ЕЛЕКТРОПОСТАЧАННЯ СТАНЦІЙ КАТОДНОГО ЗАХИСТУ ТРУБОПРОВОДІВ НА ОСНОВІ ДЕЦЕНТРАЛІЗОВАНИХ ДЖЕРЕЛ ЖИВЛЕННЯ
У статті проведено аналіз можливих джерел автономного живлення станцій катодного захисту під- земних сталевих трубопроводів. Для прийняття оптимального рішення щодо складу комплексного дже- рела живлення станції катодного захисту запропоновано сім критеріїв оцінки. Приділено особливу увагу вирішенню оптимізаційної задачі вибору структури комплексного джерела електропостачання для відда- лених або незаселених регіонів без централізованого електропостачання. За основу електрогенеруючих комплексів прийнято сонячні (СЕС) та вітрові (ВЕС) електростанції. Під час моделювання індексів надій- ності враховано наявність Storage-систем для вирівнювання добових графіків навантаження станцій.Дослідження енергетичних структур системи катодного захисту виконувалося на основі досвіду, набу- того під час виконання комплексного моніторингу рівнів захисного потенціалу та первинних електричних параметрів станцій на різноманітних газотранспортних об’єктах України.
- 9 December 2025
- Published by Publishing House Helvetica (Publications) in Електротехнічні та інформаційні системи
- No. 108,p. 3-7
Open AccessВИБІР ОПТИМАЛЬНОЇ СТРУКТУРИ ЕЛЕКТРОПОСТАЧАННЯ СТАНЦІЙ КАТОДНОГО ЗАХИСТУ ТРУБОПРОВОДІВ НА ОСНОВІ ДЕЦЕНТРАЛІЗОВАНИХ ДЖЕРЕЛ ЖИВЛЕННЯ
У статті проведено аналіз можливих джерел автономного живлення станцій катодного захисту під- земних сталевих трубопроводів. Для прийняття оптимального рішення щодо складу комплексного дже- рела живлення станції катодного захисту запропоновано сім критеріїв оцінки. Приділено особливу увагу вирішенню оптимізаційної задачі вибору структури комплексного джерела електропостачання для відда- лених або незаселених регіонів без централізованого електропостачання. За основу електрогенеруючих комплексів прийнято сонячні (СЕС) та вітрові (ВЕС) електростанції. Під час моделювання індексів надій- ності враховано наявність Storage-систем для вирівнювання добових графіків навантаження станцій.Дослідження енергетичних структур системи катодного захисту виконувалося на основі досвіду, набу- того під час виконання комплексного моніторингу рівнів захисного потенціалу та первинних електричних параметрів станцій на різноманітних газотранспортних об’єктах України.
- 30 April 2025
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 2,p. 155-163
Influence of the protective potential distribution of a steel underground pipeline on electrochemical corrosion processes
Purpose. To distinguish the influence of inserts, with high resistance to the flow of electric current, which causes deviations of the protective potential along the length of the pipeline from its classical form. Obtaining analytical dependencies in the form of a transfer function that relates the input and output signal. That allows predicting dangerous deviations of the protective potential, the combination of which indicates a worsening of corrosion protection. Methodology. To achieve this purpose, the methods of theoretical analysis, mathematical and computer modeling, and spectral analysis of signals are used. The initial information characterizing the operating modes of adjacent cathode stations is obtained and verified based on the data from monitoring the protective potential along the tracks of underground steel pipelines of various designs. The parameters taken into account in the calculations include the geometric dimensions of the pipeline, soil condition, insulation resistance, etc. By analyzing the results of measurements obtained with the help of a recording voltmeter “PRIMA 2000” and a detector “Sprut-17”, the growth of corrosion risks arising from the repair of a damaged section of an underground steel pipeline using polyethylene pipes is established and analyzed in detail. Findings. A modeling of the operating modes of adjacent cathodic protection stations, between which there is a section of polyethylene pipeline, with the electrical parameters of an underground steel pipeline is performed. Based on the information obtained, attention is drawn to possible rational energy operation modes of adjacent cathodic protection stations, the main task of which is to reduce the corrosive effects of the polyethylene section of the underground pipeline. Originality. The paper is to substantiate the possibility of such a negative impact of a polyethylene insert in a steel pipeline, which increases the corrosion hazard. The dependence is obtained of the protective potential of cathodic protection stations in sections of the pipeline with polyethylene inserts from the operating modes of the electrical system with energy converters and their voltage generation algorithms at the output of cathodic protection stations. Practical value. The paper analyzes the signals of rectifiers of cathodic protection stations and power switches commutation modes that are aimed at improvement of the complex corrosion situation on low and medium pressure pipelines, which are characterized by heterogeneity of structure, especially within populated areas. The proposed modes of operation of adjacent cathodic protection stations reduce the level of corrosion hazard caused by the massive introduction of polyethylene pipes and their widespread use for repairing damaged sections of steel pipelines.
- 30 April 2025
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 2,p. 155-163
Influence of the protective potential distribution of a steel underground pipeline on electrochemical corrosion processes
Purpose. To distinguish the influence of inserts, with high resistance to the flow of electric current, which causes deviations of the protective potential along the length of the pipeline from its classical form. Obtaining analytical dependencies in the form of a transfer function that relates the input and output signal. That allows predicting dangerous deviations of the protective potential, the combination of which indicates a worsening of corrosion protection. Methodology. To achieve this purpose, the methods of theoretical analysis, mathematical and computer modeling, and spectral analysis of signals are used. The initial information characterizing the operating modes of adjacent cathode stations is obtained and verified based on the data from monitoring the protective potential along the tracks of underground steel pipelines of various designs. The parameters taken into account in the calculations include the geometric dimensions of the pipeline, soil condition, insulation resistance, etc. By analyzing the results of measurements obtained with the help of a recording voltmeter “PRIMA 2000” and a detector “Sprut-17”, the growth of corrosion risks arising from the repair of a damaged section of an underground steel pipeline using polyethylene pipes is established and analyzed in detail. Findings. A modeling of the operating modes of adjacent cathodic protection stations, between which there is a section of polyethylene pipeline, with the electrical parameters of an underground steel pipeline is performed. Based on the information obtained, attention is drawn to possible rational energy operation modes of adjacent cathodic protection stations, the main task of which is to reduce the corrosive effects of the polyethylene section of the underground pipeline. Originality. The paper is to substantiate the possibility of such a negative impact of a polyethylene insert in a steel pipeline, which increases the corrosion hazard. The dependence is obtained of the protective potential of cathodic protection stations in sections of the pipeline with polyethylene inserts from the operating modes of the electrical system with energy converters and their voltage generation algorithms at the output of cathodic protection stations. Practical value. The paper analyzes the signals of rectifiers of cathodic protection stations and power switches commutation modes that are aimed at improvement of the complex corrosion situation on low and medium pressure pipelines, which are characterized by heterogeneity of structure, especially within populated areas. The proposed modes of operation of adjacent cathodic protection stations reduce the level of corrosion hazard caused by the massive introduction of polyethylene pipes and their widespread use for repairing damaged sections of steel pipelines.
- 30 December 2024
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 6,p. 73-78
Simulation of the operation modes of the catodic protection complex of pipelines in the approach of overhead power lines
Purpose. The purpose of the work is to establish the dependences of the levels of the protective potential of the system of protection of underground steel pipelines when approaching and/or crossing overhead power lines. Methodology. To achieve the goal, the methods of the theory of equivalent electric circuits and the theory of the electromagnetic field, implemented in the packages of applied computer programs Matlab/Simulink and COMSOL Multiphysics, were used. Findings. The spatial distribution in the soil of the induced electric field of the overhead power line in the direct location of the pipeline, which varies with a frequency of 50 Hz, was determined. The distribution of both constant and alternating voltage on the pipeline relative to the soil is given. An analysis of corrosion processes in the pipeline was carried out, on the basis of which the relatively safe flow of corrosion processes in the pipeline under the action of simultaneously occurring alternating current with a frequency of 50 Hz and direct current was investigated. Originality. The scientific novelty of the work consists in determining the regularities of the influence of overhead lines on the nature of the distribution of the protective potential of cathodic protection stations with variable changes in the configuration of pipelines and laying conditions. The existence of significant deviations of the levels of the protective potential in the presence of a variable polyharmonic component of the signal is proven. On the basis of the study, it was established that under the accepted initial conditions, both criteria are unsatisfactory in some sections of the pipeline near the power transmission line. Practical value. The practical significance of the research results is in determining the set of technical characteristics of the electrotechnical complex of protection against electrochemical corrosion, which allows ensuring the necessary levels of protective potential in the presence of a source of stray currents (overhead power lines).
- 30 December 2024
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 6,p. 73-78
Simulation of the operation modes of the catodic protection complex of pipelines in the approach of overhead power lines
Purpose. The purpose of the work is to establish the dependences of the levels of the protective potential of the system of protection of underground steel pipelines when approaching and/or crossing overhead power lines. Methodology. To achieve the goal, the methods of the theory of equivalent electric circuits and the theory of the electromagnetic field, implemented in the packages of applied computer programs Matlab/Simulink and COMSOL Multiphysics, were used. Findings. The spatial distribution in the soil of the induced electric field of the overhead power line in the direct location of the pipeline, which varies with a frequency of 50 Hz, was determined. The distribution of both constant and alternating voltage on the pipeline relative to the soil is given. An analysis of corrosion processes in the pipeline was carried out, on the basis of which the relatively safe flow of corrosion processes in the pipeline under the action of simultaneously occurring alternating current with a frequency of 50 Hz and direct current was investigated. Originality. The scientific novelty of the work consists in determining the regularities of the influence of overhead lines on the nature of the distribution of the protective potential of cathodic protection stations with variable changes in the configuration of pipelines and laying conditions. The existence of significant deviations of the levels of the protective potential in the presence of a variable polyharmonic component of the signal is proven. On the basis of the study, it was established that under the accepted initial conditions, both criteria are unsatisfactory in some sections of the pipeline near the power transmission line. Practical value. The practical significance of the research results is in determining the set of technical characteristics of the electrotechnical complex of protection against electrochemical corrosion, which allows ensuring the necessary levels of protective potential in the presence of a source of stray currents (overhead power lines).
- Open Access
- 15 August 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2024 (5) , 85-93
CONSIDERATION OF THE VARIABLE STORAGE POTENTIAL OF UNDERGROUND STEEL PIPELINES IN THE DEVELOPMENT OF ELECTRICAL COMPLEXES FOR THEIR PROTECTION AGAINST ELECTROCHEMICAL CORROSION
The paper analyzes the problem of protection of underground metal pipelines using active cathodic protection. Shortcomings and emergency situations of active defense complexes are given. Analytical dependences of determining the levels of the protective potential in the conditions of a heterogeneous environment, various variations of the topology of laying the pipeline system are generally presented. The results of comprehensive monitoring of the operation modes of electrotechnical complexes of electrochemical protection allowed to develop a universal methodology for creating energy-efficient and reliable systems of cathodic protection of pipelines. References 22, figures 11.
- 15 August 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2024 (5) , 85-93
Open AccessCONSIDERATION OF THE VARIABLE STORAGE POTENTIAL OF UNDERGROUND STEEL PIPELINES IN THE DEVELOPMENT OF ELECTRICAL COMPLEXES FOR THEIR PROTECTION AGAINST ELECTROCHEMICAL CORROSION
The paper analyzes the problem of protection of underground metal pipelines using active cathodic protection. Shortcomings and emergency situations of active defense complexes are given. Analytical dependences of determining the levels of the protective potential in the conditions of a heterogeneous environment, various variations of the topology of laying the pipeline system are generally presented. The results of comprehensive monitoring of the operation modes of electrotechnical complexes of electrochemical protection allowed to develop a universal methodology for creating energy-efficient and reliable systems of cathodic protection of pipelines. References 22, figures 11.
- Open Access
- 1 April 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2024 (2) , 23-29
REGULATIONS OF THE FORMATION OF PROTECTIVE POTENTIAL OF UNDERGROUND STEEL PIPELINES UNDER CONDITIONS OF HETEROGENEOUS ENVIRONMENT
In the work, the modeling of the distribution of the protective potential of electrochemical protection stations is performed by revealed functional dependencies. The initial conditions are adopted for a typical assortment of rolled metal used for underground gas supply. At the initial stage of modeling, the stochastic nature of the change in soil parameters is not taken into account. The distribution of the protective potential of the underground pipeline as a function of two variables (time and distance) showed the mutual influence of neighboring stations on the formation of protective zone. New dependences of the operating parameters of the electrotechnical complex of electrochemical protection on the set of variables characterizing the power source, the physical dimensions of pipeline and the alternative arrangement of active cathodic protection stations (CPS) were obtained. Experimental studies of the modes of electrochemical protection stations at the objects of the gas transportation system of Ukraine confirmed the adequacy of the proposed analytical models. References 16, Figures 3. У роботі виконано моделювання розподілу захисного потенціалу станцій електрохімічного захисту на основі отриманих функціональний залежностей. Початкові умови прийнято для типового сортаменту металопрокату, що застосовується для підземного газопостачання. На початковому етапі моделювання стохастичний характер змінення параметрів ґрунтів не враховано. Розподіл захисного потенціалу підземного трубопроводу в функції двох змінних (часу та дистанції) показав взаємний вплив сусідніх станцій на формування захисної зони. Отримано нові залежності режимних параметрів електротехнічного комплексу електрохімічного захисту від комплексу змінних, що характеризують джерело живлення, фізичні розміри трубопроводу та варіативне розташування активних катодних станцій. Експериментальні дослідження режимів станцій електрохімічного захисту на об’єктах газотранспортної системи України підтвердили адекватність запропонованих аналітичних моделей. Бібл. 16, рис. 3.
- 1 April 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2024 (2) , 23-29
Open AccessREGULATIONS OF THE FORMATION OF PROTECTIVE POTENTIAL OF UNDERGROUND STEEL PIPELINES UNDER CONDITIONS OF HETEROGENEOUS ENVIRONMENT
In the work, the modeling of the distribution of the protective potential of electrochemical protection stations is performed by revealed functional dependencies. The initial conditions are adopted for a typical assortment of rolled metal used for underground gas supply. At the initial stage of modeling, the stochastic nature of the change in soil parameters is not taken into account. The distribution of the protective potential of the underground pipeline as a function of two variables (time and distance) showed the mutual influence of neighboring stations on the formation of protective zone. New dependences of the operating parameters of the electrotechnical complex of electrochemical protection on the set of variables characterizing the power source, the physical dimensions of pipeline and the alternative arrangement of active cathodic protection stations (CPS) were obtained. Experimental studies of the modes of electrochemical protection stations at the objects of the gas transportation system of Ukraine confirmed the adequacy of the proposed analytical models. References 16, Figures 3. У роботі виконано моделювання розподілу захисного потенціалу станцій електрохімічного захисту на основі отриманих функціональний залежностей. Початкові умови прийнято для типового сортаменту металопрокату, що застосовується для підземного газопостачання. На початковому етапі моделювання стохастичний характер змінення параметрів ґрунтів не враховано. Розподіл захисного потенціалу підземного трубопроводу в функції двох змінних (часу та дистанції) показав взаємний вплив сусідніх станцій на формування захисної зони. Отримано нові залежності режимних параметрів електротехнічного комплексу електрохімічного захисту від комплексу змінних, що характеризують джерело живлення, фізичні розміри трубопроводу та варіативне розташування активних катодних станцій. Експериментальні дослідження режимів станцій електрохімічного захисту на об’єктах газотранспортної системи України підтвердили адекватність запропонованих аналітичних моделей. Бібл. 16, рис. 3.