Yurii Papaika
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yurii Papaika has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Олександр Олександрович Азюковський
Національний технічний університет «Дніпровська політехніка
6 shared publications - Олександра Геннадіївна Лисенко
Dnipro University of Technology, Dmytra Yavornytskoho Ave 19, Dnipro, Ukraine
6 shared publications - O.V. Udovyk
НТУ «Дніпровська політехніка
3 shared publications - Микола Володимирович Бабенко
Національний технічний університет «Дніпровська політехніка
3 shared publications - Alla Polyanska
Івано-Франківський національний технічний університет нафти і газу
2 shared publications - Andrii Viktorovych Bublikov
Національний технічний університет “Дніпровська політехніка
2 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by National University "Zaporizhzhia Polytechnic" in Electrical Engineering and Power Engineering
- No. 3,p. 60-68
Role of distributed generation in enhancing the resilience of power systems to external disturbances
Purpose. This study investigates the role of distributed generation in enhancing the resilience of power systems to external disturbances. It aims to identify the mechanisms for improving power system survivability, determine the technical challenges associated with the integration of distributed generation, and assess the prospects for the development of microgrids and energy storage systems. Methodology. The research is based on the methods of system and comparative analysis of power systems, a review of international experience in distributed generation development, and the generalization of data on the operation of Ukraine's energy infrastructure. Findings. The impact of distributed generation on enhancing the resilience of power systems to external disturbances was analyzed. A comprehensive review of recent international studies demonstrated that the integration of distributed generation significantly improves conventional power supply reliability indices by reducing the frequency and duration of power interruptions, decreasing Energy Not Supplied (ENS), lowering power losses, and increasing system availability. It was established that the greatest resilience benefits are achieved through the integrated deployment of distributed generation, energy storage systems, microgrids, and Distributed Energy Resource Management Systems (DERMS), which enable autonomous (islanded) operation, maintain electricity supply to critical loads, and reduce post-disturbance restoration time. The study also identified the principal technical challenges associated with large-scale distributed generation integration, including variations in short-circuit current levels, reverse power flows, protection coordination issues, and the increasing penetration of inverter-based generation. In addition, promising directions for the further development of distributed generation were determined, emphasizing hybrid renewable energy systems, energy storage technologies, adaptive digital protection systems, and intelligent microgrids as key components for improving the resilience and survivability of modern power systems. Originality. Modern approaches to assessing the impact of distributed generation on power system resilience were generalized. The principal mechanisms for enhancing power system resilience and the technical constraints related to the integration of distributed generation, microgrids, and energy storage systems were systematized. Practical value. The research findings can be applied to planning the development of distributed generation, designing microgrids, modernizing power system protection schemes, and developing measures aimed at improving power system resilience and ensuring a reliable electricity supply for critical infrastructure.
- 30 September 2026
- Published by National University "Zaporizhzhia Polytechnic" in Electrical Engineering and Power Engineering
- No. 3,p. 60-68
Open AccessRole of distributed generation in enhancing the resilience of power systems to external disturbances
Purpose. This study investigates the role of distributed generation in enhancing the resilience of power systems to external disturbances. It aims to identify the mechanisms for improving power system survivability, determine the technical challenges associated with the integration of distributed generation, and assess the prospects for the development of microgrids and energy storage systems. Methodology. The research is based on the methods of system and comparative analysis of power systems, a review of international experience in distributed generation development, and the generalization of data on the operation of Ukraine's energy infrastructure. Findings. The impact of distributed generation on enhancing the resilience of power systems to external disturbances was analyzed. A comprehensive review of recent international studies demonstrated that the integration of distributed generation significantly improves conventional power supply reliability indices by reducing the frequency and duration of power interruptions, decreasing Energy Not Supplied (ENS), lowering power losses, and increasing system availability. It was established that the greatest resilience benefits are achieved through the integrated deployment of distributed generation, energy storage systems, microgrids, and Distributed Energy Resource Management Systems (DERMS), which enable autonomous (islanded) operation, maintain electricity supply to critical loads, and reduce post-disturbance restoration time. The study also identified the principal technical challenges associated with large-scale distributed generation integration, including variations in short-circuit current levels, reverse power flows, protection coordination issues, and the increasing penetration of inverter-based generation. In addition, promising directions for the further development of distributed generation were determined, emphasizing hybrid renewable energy systems, energy storage technologies, adaptive digital protection systems, and intelligent microgrids as key components for improving the resilience and survivability of modern power systems. Originality. Modern approaches to assessing the impact of distributed generation on power system resilience were generalized. The principal mechanisms for enhancing power system resilience and the technical constraints related to the integration of distributed generation, microgrids, and energy storage systems were systematized. Practical value. The research findings can be applied to planning the development of distributed generation, designing microgrids, modernizing power system protection schemes, and developing measures aimed at improving power system resilience and ensuring a reliable electricity supply for critical infrastructure.
- Open Access
- 17 March 2026
- Published by University of Applied Sciences in Tarnow, Poland in Science, Technology and Innovation
- Vol. 23 (4) , 1-7
Use of renewable sources in the industrial power system during military operations
The article examines the possibilities of using renewable energy sources for distributed generation in the Ukrainian power system. Potential risks and possible scenarios for the occurrence of resonance phenomena in the circuits of large-scale grid-connected solar power plants are discussed. The results of amplitude–frequency characteristic modeling identify the limiting ranges of resonance frequencies under varying numbers of STATCOM devices and different power supply system parameters. The issue of electromagnetic compatibility between solar inverters and a centralized power system with limited capacity is investigated. The effect of higher-order current harmonic absorption resulting from changes in the power of industrial load nodes is described. Studies of the electromagnetic interactions between solar power plants and industrial loads are essential for the further development of electromagnetic compatibility theory.
- 17 March 2026
- Published by University of Applied Sciences in Tarnow, Poland in Science, Technology and Innovation
- Vol. 23 (4) , 1-7
Open AccessUse of renewable sources in the industrial power system during military operations
The article examines the possibilities of using renewable energy sources for distributed generation in the Ukrainian power system. Potential risks and possible scenarios for the occurrence of resonance phenomena in the circuits of large-scale grid-connected solar power plants are discussed. The results of amplitude–frequency characteristic modeling identify the limiting ranges of resonance frequencies under varying numbers of STATCOM devices and different power supply system parameters. The issue of electromagnetic compatibility between solar inverters and a centralized power system with limited capacity is investigated. The effect of higher-order current harmonic absorption resulting from changes in the power of industrial load nodes is described. Studies of the electromagnetic interactions between solar power plants and industrial loads are essential for the further development of electromagnetic compatibility theory.
- Open Access
- 22 October 2025
- Published by National University "Zaporizhzhia Polytechnic" in Electrical Engineering and Power Engineering
- No. 3,p. 44-51
Analysis of special operating modes of industrial electrical networks with an isolated neutral
Purpose. Development of methodological and technical solutions aimed at improving energy efficiency and ensuring the reliability of power supply systems of industrial enterprises. Methodology. System analysis of operating modes of power supply systems, experimental measurements using hardware–software complexes, and assessment of their impact on reliability and power quality indicators. Results obtained. An approach to the formation of operating modes of power supply systems that contributes to improving energy efficiency has been proposed. The influence of transient processes on power quality has been investigated, and practical recommendations for optimizing the operation of energy-intensive enterprises have been substantiated. Scientific Novelty. An innovative methodology for monitoring the insulation parameters of electrical networks operating at 6–10 kV has been developed, enabling diagnostics under real operating conditions. Practical Value. The study proposes a comprehensive framework aimed at enhancing the energy efficiency and reliability of power supply systems. The obtained results are applicable to the modernization and optimization of industrial power networks.
- 22 October 2025
- Published by National University "Zaporizhzhia Polytechnic" in Electrical Engineering and Power Engineering
- No. 3,p. 44-51
Open AccessAnalysis of special operating modes of industrial electrical networks with an isolated neutral
Purpose. Development of methodological and technical solutions aimed at improving energy efficiency and ensuring the reliability of power supply systems of industrial enterprises. Methodology. System analysis of operating modes of power supply systems, experimental measurements using hardware–software complexes, and assessment of their impact on reliability and power quality indicators. Results obtained. An approach to the formation of operating modes of power supply systems that contributes to improving energy efficiency has been proposed. The influence of transient processes on power quality has been investigated, and practical recommendations for optimizing the operation of energy-intensive enterprises have been substantiated. Scientific Novelty. An innovative methodology for monitoring the insulation parameters of electrical networks operating at 6–10 kV has been developed, enabling diagnostics under real operating conditions. Practical Value. The study proposes a comprehensive framework aimed at enhancing the energy efficiency and reliability of power supply systems. The obtained results are applicable to the modernization and optimization of industrial power networks.
- Open Access
- 30 April 2025
- Published by National University "Zaporizhzhia Polytechnic" in Electrical Engineering and Power Engineering
- No. 1,p. 53-60
Study of the nature of emergency transient processes in power supply systems of enterprises
Purpose. To investigate the nature of emergency transient processes in power supply systems of enterprises in order to identify the main causes of emergency situations, identify the features of the processes, and assess their impact on the reliability of power supply systems. The article aims to study the impact of neutral modes on human safety and to study methods for controlling the insulation of networks with a voltage of 6–10 kV to improve the safety of operation of electrical networks of enterprises. Methodology. The study of the nature of emergency transient processes was carried out through statistical analysis of data processing on the occurrence of emergency situations at operating enterprises of Ukraine and analysis of existing calculation methods given in the scientific and technical literature. The main causes and patterns of process development were determined by analyzing emergency processes that occur in networks with an isolated neutral during a single-phase "metal" ground fault at the initial stages of the emergency mode and in the post-emergency mode. Findings. The result of the analysis of the main patterns of the course of emergency transient processes in the power supply systems of enterprises is the determination of the initial nature of the processes in networks with an isolated neutral during a single-phase ground fault and the nature of the processes in the post-emergency operating mode. The article also derives formulas for calculating the neutral mode impact on human electrical safety during the operation of distribution networks. In order to increase the reliability of power supply systems and reduce the likelihood of emergency situations, the article proposes a method for controlling the insulation parameters of electrical networks with a voltage of 6 - 10 kV. Originality. Determination of the modern equipment impact on the nature of emergency transients, including nonlinear load and higher harmonics. Evaluation of the relationship between the transient process parameters and the power supply reliability, the impact of emergency modes on the technological processes of the enterprise. Practical value. The result of the study makes it possible to assess the consequences of emergency transients in the power supply systems of enterprises, which leads to an increase in the reliability of power supply systems and improvement of labor safety conditions at energy facilities. Study of the influence of the neutral mode on electrical safety during the operation of distribution networks.
- 30 April 2025
- Published by National University "Zaporizhzhia Polytechnic" in Electrical Engineering and Power Engineering
- No. 1,p. 53-60
Open AccessStudy of the nature of emergency transient processes in power supply systems of enterprises
Purpose. To investigate the nature of emergency transient processes in power supply systems of enterprises in order to identify the main causes of emergency situations, identify the features of the processes, and assess their impact on the reliability of power supply systems. The article aims to study the impact of neutral modes on human safety and to study methods for controlling the insulation of networks with a voltage of 6–10 kV to improve the safety of operation of electrical networks of enterprises. Methodology. The study of the nature of emergency transient processes was carried out through statistical analysis of data processing on the occurrence of emergency situations at operating enterprises of Ukraine and analysis of existing calculation methods given in the scientific and technical literature. The main causes and patterns of process development were determined by analyzing emergency processes that occur in networks with an isolated neutral during a single-phase "metal" ground fault at the initial stages of the emergency mode and in the post-emergency mode. Findings. The result of the analysis of the main patterns of the course of emergency transient processes in the power supply systems of enterprises is the determination of the initial nature of the processes in networks with an isolated neutral during a single-phase ground fault and the nature of the processes in the post-emergency operating mode. The article also derives formulas for calculating the neutral mode impact on human electrical safety during the operation of distribution networks. In order to increase the reliability of power supply systems and reduce the likelihood of emergency situations, the article proposes a method for controlling the insulation parameters of electrical networks with a voltage of 6 - 10 kV. Originality. Determination of the modern equipment impact on the nature of emergency transients, including nonlinear load and higher harmonics. Evaluation of the relationship between the transient process parameters and the power supply reliability, the impact of emergency modes on the technological processes of the enterprise. Practical value. The result of the study makes it possible to assess the consequences of emergency transients in the power supply systems of enterprises, which leads to an increase in the reliability of power supply systems and improvement of labor safety conditions at energy facilities. Study of the influence of the neutral mode on electrical safety during the operation of distribution networks.
- 30 December 2024
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 6,p. 73-78
Simulation of the operation modes of the catodic protection complex of pipelines in the approach of overhead power lines
Purpose. The purpose of the work is to establish the dependences of the levels of the protective potential of the system of protection of underground steel pipelines when approaching and/or crossing overhead power lines. Methodology. To achieve the goal, the methods of the theory of equivalent electric circuits and the theory of the electromagnetic field, implemented in the packages of applied computer programs Matlab/Simulink and COMSOL Multiphysics, were used. Findings. The spatial distribution in the soil of the induced electric field of the overhead power line in the direct location of the pipeline, which varies with a frequency of 50 Hz, was determined. The distribution of both constant and alternating voltage on the pipeline relative to the soil is given. An analysis of corrosion processes in the pipeline was carried out, on the basis of which the relatively safe flow of corrosion processes in the pipeline under the action of simultaneously occurring alternating current with a frequency of 50 Hz and direct current was investigated. Originality. The scientific novelty of the work consists in determining the regularities of the influence of overhead lines on the nature of the distribution of the protective potential of cathodic protection stations with variable changes in the configuration of pipelines and laying conditions. The existence of significant deviations of the levels of the protective potential in the presence of a variable polyharmonic component of the signal is proven. On the basis of the study, it was established that under the accepted initial conditions, both criteria are unsatisfactory in some sections of the pipeline near the power transmission line. Practical value. The practical significance of the research results is in determining the set of technical characteristics of the electrotechnical complex of protection against electrochemical corrosion, which allows ensuring the necessary levels of protective potential in the presence of a source of stray currents (overhead power lines).
- 30 December 2024
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 6,p. 73-78
Simulation of the operation modes of the catodic protection complex of pipelines in the approach of overhead power lines
Purpose. The purpose of the work is to establish the dependences of the levels of the protective potential of the system of protection of underground steel pipelines when approaching and/or crossing overhead power lines. Methodology. To achieve the goal, the methods of the theory of equivalent electric circuits and the theory of the electromagnetic field, implemented in the packages of applied computer programs Matlab/Simulink and COMSOL Multiphysics, were used. Findings. The spatial distribution in the soil of the induced electric field of the overhead power line in the direct location of the pipeline, which varies with a frequency of 50 Hz, was determined. The distribution of both constant and alternating voltage on the pipeline relative to the soil is given. An analysis of corrosion processes in the pipeline was carried out, on the basis of which the relatively safe flow of corrosion processes in the pipeline under the action of simultaneously occurring alternating current with a frequency of 50 Hz and direct current was investigated. Originality. The scientific novelty of the work consists in determining the regularities of the influence of overhead lines on the nature of the distribution of the protective potential of cathodic protection stations with variable changes in the configuration of pipelines and laying conditions. The existence of significant deviations of the levels of the protective potential in the presence of a variable polyharmonic component of the signal is proven. On the basis of the study, it was established that under the accepted initial conditions, both criteria are unsatisfactory in some sections of the pipeline near the power transmission line. Practical value. The practical significance of the research results is in determining the set of technical characteristics of the electrotechnical complex of protection against electrochemical corrosion, which allows ensuring the necessary levels of protective potential in the presence of a source of stray currents (overhead power lines).
- Open Access
- 11 December 2024
- Published by Instytut Gospodarki Surowcami Mineralnymi i Energia Polskiej Akademii Nauk in Polityka Energetyczna – Energy Policy Journal
- Vol. 27 (4) , 59-80
Managing the power supply energy efficiency by means of higher harmonics
- 11 December 2024
- Published by Instytut Gospodarki Surowcami Mineralnymi i Energia Polskiej Akademii Nauk in Polityka Energetyczna – Energy Policy Journal
- Vol. 27 (4) , 59-80
Open AccessManaging the power supply energy efficiency by means of higher harmonics
- Open Access
- 30 October 2024
- Published by National University "Zaporizhzhia Polytechnic" in Electrical Engineering and Power Engineering
- No. 3,p. 36-44
Determination of voltage quality indicators in industrial power supply systems with limited energy system capacity
Purpose. To justify the dependence of the determination of indicators of electromagnetic compatibility of power supply systems of industrial enterprises in the presence of powerful nonlinear and asymmetric loads in conditions of limited power system capacity. Methodology. Methods of theoretical electrical engineering for the construction of replacement schemes of three-phase electrical networks, Fourier series for the analysis of higher harmonics of current and voltage, the method of symmetrical components for the analysis of asymmetry. Findings. Виділено основні показники якості напруги, значення яких залежить від параметрів живлячої електроенергетичної системи (потужності короткого замикання). Наведено аналітичні залежності розрахунку показників несиметрії та несинусоїдальності при обмеженні потужності КЗ. Проаналізовано засоби корекції показників якості в умовах електричних мереж з розподіленою генерацією. Originality. The scientific novelty consists in establishing the patterns of changes in the mode parameters of the industrial load from the parameters of the power system, which is expressed in interrelated changes in voltage quality indicators. At the same time, in the analytical models, the option of obtaining variable changes in the parameters of the power system both due to the generating capacities and through the parameters of the substitution schemes of electrical networks of different voltage classes has been added. Practical value. For engineering calculations, simplified algorithms for determining voltage quality indicators (deviation, oscillation, asymmetry and non-sinusoidal voltage) are proposed, taking into account the real configuration of the electrical network and the actual power of the power system. This makes it possible to evaluate the efficiency of transmission and conversion of electricity under an arbitrary configuration of the post-emergency power supply scheme.
- 30 October 2024
- Published by National University "Zaporizhzhia Polytechnic" in Electrical Engineering and Power Engineering
- No. 3,p. 36-44
Open AccessDetermination of voltage quality indicators in industrial power supply systems with limited energy system capacity
Purpose. To justify the dependence of the determination of indicators of electromagnetic compatibility of power supply systems of industrial enterprises in the presence of powerful nonlinear and asymmetric loads in conditions of limited power system capacity. Methodology. Methods of theoretical electrical engineering for the construction of replacement schemes of three-phase electrical networks, Fourier series for the analysis of higher harmonics of current and voltage, the method of symmetrical components for the analysis of asymmetry. Findings. Виділено основні показники якості напруги, значення яких залежить від параметрів живлячої електроенергетичної системи (потужності короткого замикання). Наведено аналітичні залежності розрахунку показників несиметрії та несинусоїдальності при обмеженні потужності КЗ. Проаналізовано засоби корекції показників якості в умовах електричних мереж з розподіленою генерацією. Originality. The scientific novelty consists in establishing the patterns of changes in the mode parameters of the industrial load from the parameters of the power system, which is expressed in interrelated changes in voltage quality indicators. At the same time, in the analytical models, the option of obtaining variable changes in the parameters of the power system both due to the generating capacities and through the parameters of the substitution schemes of electrical networks of different voltage classes has been added. Practical value. For engineering calculations, simplified algorithms for determining voltage quality indicators (deviation, oscillation, asymmetry and non-sinusoidal voltage) are proposed, taking into account the real configuration of the electrical network and the actual power of the power system. This makes it possible to evaluate the efficiency of transmission and conversion of electricity under an arbitrary configuration of the post-emergency power supply scheme.
- Open Access
- 15 August 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2024 (5) , 85-93
CONSIDERATION OF THE VARIABLE STORAGE POTENTIAL OF UNDERGROUND STEEL PIPELINES IN THE DEVELOPMENT OF ELECTRICAL COMPLEXES FOR THEIR PROTECTION AGAINST ELECTROCHEMICAL CORROSION
The paper analyzes the problem of protection of underground metal pipelines using active cathodic protection. Shortcomings and emergency situations of active defense complexes are given. Analytical dependences of determining the levels of the protective potential in the conditions of a heterogeneous environment, various variations of the topology of laying the pipeline system are generally presented. The results of comprehensive monitoring of the operation modes of electrotechnical complexes of electrochemical protection allowed to develop a universal methodology for creating energy-efficient and reliable systems of cathodic protection of pipelines. References 22, figures 11.
- 15 August 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2024 (5) , 85-93
Open AccessCONSIDERATION OF THE VARIABLE STORAGE POTENTIAL OF UNDERGROUND STEEL PIPELINES IN THE DEVELOPMENT OF ELECTRICAL COMPLEXES FOR THEIR PROTECTION AGAINST ELECTROCHEMICAL CORROSION
The paper analyzes the problem of protection of underground metal pipelines using active cathodic protection. Shortcomings and emergency situations of active defense complexes are given. Analytical dependences of determining the levels of the protective potential in the conditions of a heterogeneous environment, various variations of the topology of laying the pipeline system are generally presented. The results of comprehensive monitoring of the operation modes of electrotechnical complexes of electrochemical protection allowed to develop a universal methodology for creating energy-efficient and reliable systems of cathodic protection of pipelines. References 22, figures 11.
- Open Access
- 1 April 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2024 (2) , 23-29
REGULATIONS OF THE FORMATION OF PROTECTIVE POTENTIAL OF UNDERGROUND STEEL PIPELINES UNDER CONDITIONS OF HETEROGENEOUS ENVIRONMENT
In the work, the modeling of the distribution of the protective potential of electrochemical protection stations is performed by revealed functional dependencies. The initial conditions are adopted for a typical assortment of rolled metal used for underground gas supply. At the initial stage of modeling, the stochastic nature of the change in soil parameters is not taken into account. The distribution of the protective potential of the underground pipeline as a function of two variables (time and distance) showed the mutual influence of neighboring stations on the formation of protective zone. New dependences of the operating parameters of the electrotechnical complex of electrochemical protection on the set of variables characterizing the power source, the physical dimensions of pipeline and the alternative arrangement of active cathodic protection stations (CPS) were obtained. Experimental studies of the modes of electrochemical protection stations at the objects of the gas transportation system of Ukraine confirmed the adequacy of the proposed analytical models. References 16, Figures 3. У роботі виконано моделювання розподілу захисного потенціалу станцій електрохімічного захисту на основі отриманих функціональний залежностей. Початкові умови прийнято для типового сортаменту металопрокату, що застосовується для підземного газопостачання. На початковому етапі моделювання стохастичний характер змінення параметрів ґрунтів не враховано. Розподіл захисного потенціалу підземного трубопроводу в функції двох змінних (часу та дистанції) показав взаємний вплив сусідніх станцій на формування захисної зони. Отримано нові залежності режимних параметрів електротехнічного комплексу електрохімічного захисту від комплексу змінних, що характеризують джерело живлення, фізичні розміри трубопроводу та варіативне розташування активних катодних станцій. Експериментальні дослідження режимів станцій електрохімічного захисту на об’єктах газотранспортної системи України підтвердили адекватність запропонованих аналітичних моделей. Бібл. 16, рис. 3.
- 1 April 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2024 (2) , 23-29
Open AccessREGULATIONS OF THE FORMATION OF PROTECTIVE POTENTIAL OF UNDERGROUND STEEL PIPELINES UNDER CONDITIONS OF HETEROGENEOUS ENVIRONMENT
In the work, the modeling of the distribution of the protective potential of electrochemical protection stations is performed by revealed functional dependencies. The initial conditions are adopted for a typical assortment of rolled metal used for underground gas supply. At the initial stage of modeling, the stochastic nature of the change in soil parameters is not taken into account. The distribution of the protective potential of the underground pipeline as a function of two variables (time and distance) showed the mutual influence of neighboring stations on the formation of protective zone. New dependences of the operating parameters of the electrotechnical complex of electrochemical protection on the set of variables characterizing the power source, the physical dimensions of pipeline and the alternative arrangement of active cathodic protection stations (CPS) were obtained. Experimental studies of the modes of electrochemical protection stations at the objects of the gas transportation system of Ukraine confirmed the adequacy of the proposed analytical models. References 16, Figures 3. У роботі виконано моделювання розподілу захисного потенціалу станцій електрохімічного захисту на основі отриманих функціональний залежностей. Початкові умови прийнято для типового сортаменту металопрокату, що застосовується для підземного газопостачання. На початковому етапі моделювання стохастичний характер змінення параметрів ґрунтів не враховано. Розподіл захисного потенціалу підземного трубопроводу в функції двох змінних (часу та дистанції) показав взаємний вплив сусідніх станцій на формування захисної зони. Отримано нові залежності режимних параметрів електротехнічного комплексу електрохімічного захисту від комплексу змінних, що характеризують джерело живлення, фізичні розміри трубопроводу та варіативне розташування активних катодних станцій. Експериментальні дослідження режимів станцій електрохімічного захисту на об’єктах газотранспортної системи України підтвердили адекватність запропонованих аналітичних моделей. Бібл. 16, рис. 3.