MEMax Ebensperger

Max Ebensperger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Max Ebensperger has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Using a Wearable-Based Animated Patient Avatar to Improve Patients’ Perception of Vital Signs: Multicenter Computer-Based Study

    by Johannes Köhler, Max Ebensperger, Cynthia A Hunn, Arend Rahrisch, Achilles Delis, Florian Piekarski, Gregor Massoth, Florian J Raimann, Kai Zacharowski, David W Tscholl, et al.

    Background: Visual patient avatars are an innovative patient monitoring technology that can be used to translate numerical and waveform data into intuitive, avatar-based representations of patient conditions. Previous research indicates that this technology improves health care providers’ situational awareness compared to conventional monitoring methods. As patient-worn continuous vital sign monitoring continues to evolve, we introduce the Visual Patient Wearable device to provide avatar-based visualization tailored to this application. Objective: This study aimed to evaluate whether a wearable-based animated patient avatar can improve patients’ perception and recall of simulated vital sign deviations compared to conventional monitoring methods, and to assess the usability and acceptance of this avatar-based visualization. Methods: This computer-based study included 67 patients from 3 academic hospitals in Central Europe. Participants were randomly assigned to a Visual Patient Wearable group or a conventional monitoring group and viewed a standardized instructional video for their allocated method. They then completed 4 randomized clinical scenarios, each displayed for 6 seconds to simulate glance-based assessment. Accuracy in recalling vital sign deviations was measured, and Visual Patient Wearable participants additionally gave user feedback on Likert scales. Results: The Visual Patient Wearable system was associated with higher detection accuracy of vital sign deviations compared with standard monitoring layouts, increasing from a median correctness of 46% (IQR 33%-63%) with conventional monitoring to a median of 67% (IQR 49%-79%) with the Visual Patient Wearable system (P<.001). This corresponded to a risk ratio of 1.34 (95% CI 1.23%-1.47%). The magnitude of this association varied across signals, with the largest relative improvement observed for heart rhythm (137% improvement, 95% CI 85%-209%), followed by oxygen saturation (SpO2; 64% improvement, 95% CI 30%-108%) and temperature (30% improvement, 95% CI 5%-60%). No statistically significant reductions in risk were observed for heart rate, respiratory rate, or blood pressure. User experience ratings based on Likert scale assessments indicated high levels of satisfaction across all 6 vital sign categories (median score 4, IQR 4-5 on a 5-point scale). Conclusions: This computer-based study suggests that Visual Patient Wearable visualizations enhance patients’ ability to detect and recall simulated vital sign deviations. Participants found the system intuitive, easy to learn, and reassuring. The Visual Patient Wearable system provides an at-a-glance interface that may support patients’ understanding of their vital signs and could facilitate communication of relevant information to clinical staff, thereby potentially contributing to informed patient engagement. The next step is to develop a software prototype for wearable devices and test it in a clinical study.


  • Open Access

    Using a Wearable-Based Animated Patient Avatar to Improve Patients’ Perception of Vital Signs: Multicenter Computer-Based Study (Preprint)

    by Johannes Köhler, Max Ebensperger, Cynthia A Hunn, Arend Rahrisch, Achilles Delis, Florian Piekarski, Gregor Massoth, Florian J Raimann, Kai Zacharowski, David W Tscholl, et al.

    BACKGROUND Visual patient avatars are an innovative patient monitoring technology that can be used to translate numerical and waveform data into intuitive, avatar-based representations of patient conditions. Previous research indicates that this technology improves health care providers’ situational awareness compared to conventional monitoring methods. As patient-worn continuous vital sign monitoring continues to evolve, we introduce the Visual Patient Wearable device to provide avatar-based visualization tailored to this application. OBJECTIVE This study aimed to evaluate whether a wearable-based animated patient avatar can improve patients’ perception and recall of simulated vital sign deviations compared to conventional monitoring methods, and to assess the usability and acceptance of this avatar-based visualization. METHODS This computer-based study included 67 patients from 3 academic hospitals in Central Europe. Participants were randomly assigned to a Visual Patient Wearable group or a conventional monitoring group and viewed a standardized instructional video for their allocated method. They then completed 4 randomized clinical scenarios, each displayed for 6 seconds to simulate glance-based assessment. Accuracy in recalling vital sign deviations was measured, and Visual Patient Wearable participants additionally gave user feedback on Likert scales. RESULTS The Visual Patient Wearable system was associated with higher detection accuracy of vital sign deviations compared with standard monitoring layouts, increasing from a median correctness of 46% (IQR 33%-63%) with conventional monitoring to a median of 67% (IQR 49%-79%) with the Visual Patient Wearable system (P<.001). This corresponded to a risk ratio of 1.34 (95% CI 1.23%-1.47%). The magnitude of this association varied across signals, with the largest relative improvement observed for heart rhythm (137% improvement, 95% CI 85%-209%), followed by oxygen saturation (SpO2; 64% improvement, 95% CI 30%-108%) and temperature (30% improvement, 95% CI 5%-60%). No statistically significant reductions in risk were observed for heart rate, respiratory rate, or blood pressure. User experience ratings based on Likert scale assessments indicated high levels of satisfaction across all 6 vital sign categories (median score 4, IQR 4-5 on a 5-point scale). CONCLUSIONS This computer-based study suggests that Visual Patient Wearable visualizations enhance patients’ ability to detect and recall simulated vital sign deviations. Participants found the system intuitive, easy to learn, and reassuring. The Visual Patient Wearable system provides an at-a-glance interface that may support patients’ understanding of their vital signs and could facilitate communication of relevant information to clinical staff, thereby potentially contributing to informed patient engagement. The next step is to develop a software prototype for wearable devices and test it in a clinical study.

  • The future of sound in patient monitoring: a call to action to embrace the evidence and move forward

    by Max Ebensperger, Tadzio R. Roche, Arend Rahrisch, Craig S. Webster, David W. Tscholl


  • Open Access

    Continuity with caveats in anesthesia: state and response entropy of the EEG

    by Max Ebensperger, Matthias Kreuzer, Stephan Kratzer, Gerhard Schneider, Stefan Schwerin

    The growing use of neuromonitoring in general anesthesia provides detailed insights into the effects of anesthetics on the brain. Our study focuses on the processed EEG indices State Entropy (SE), Response Entropy (RE), and Burst Suppression Ratio (BSR) of the GE EntropyTM Module, which serve as surrogate measures for estimating the level of anesthesia. While retrospectively analyzing SE and RE index values from patient records, we encountered a technical anomaly with a conspicuous distribution of index values. In this single-center, retrospective study, we analyzed processed intraoperative electroencephalographic (EEG) data from 15,608 patients who underwent general anesthesia. We employed various data visualization techniques, including histograms and heat maps, and fitted custom non-Gaussian curves. Individual patients’ anesthetic periods were evaluated in detail. To compare distributions, we utilized the Kolmogorov–Smirnov test and Kullback–Leibler divergence. The analysis also included the influence of the BSR on the distribution of SE and RE values. We identified distinct pillar indices for both SE and RE, i.e., index values with a higher probability of occurrence than others. These pillar index values were not age-dependent and followed a non-equidistant distribution pattern. This phenomenon occurs independently of the BSR distribution. SE and RE index values do not adhere to a continuous distribution, instead displaying prominent pillar indices with a consistent pattern of occurrence across all age groups. The specific features of the underlying algorithm responsible for this pattern remain elusive.