Torben P.P. Hornung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Torben P.P. Hornung has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Matthew Scott Rosen
A.A. Martinos Center for Biomedical Imaging, Department of Radiology (J.E.I., M.S.R.), Mass General Brigham and Harvard Medical School, Boston
2 shared publications - Neha Koonjoo
A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
2 shared publications - Sheng Shen
A. A. Martinos Center for Biomedical Imaging Massachusetts General Hospital Charlestown MA USA
2 shared publications Susu Yan
Department of Radiation Oncology, Radiation Biophysics Division, Massachusetts General Hospital, USA
2 shared publicationsFriderike K. Longarino
Department of Radiation Oncology, Radiation Biophysics Division, Massachusetts General Hospital
1 shared publication- Friderike K. Longarino
Department of Radiation Oncology, Massachusetts General Hospital, Boston, USA
1 shared publication
Latest Publications
- Open Access
- 20 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (5) , 1750-1765
Breast Coil Optimization for Low Field MRI and Future MR-Guided Proton Therapy
Objective: Magnetic resonance imaging of the breast and the chest wall imaging was performed at ultra-low field (ULF) using optimal radiofrequency (RF) coil designs and, with an eye toward future application in MR-guided proton therapy (MRgPT), simulation studies of a pencil proton beam trajectory in low and ultra-low magnetic fields were performed. Methods: The primary focus in this study is the RF coil design, which is approached as a multi-objective optimization (MOO) problem and effectively solved using a Pareto optimality formalism. Our coil winding pattern algorithm simultaneously optimizes the magnetic field homogeneity of the coil, the attainable MRI signal-to-noise ratio (SNR), and the magnetic field drop-off into the chest wall for improved OAR imaging. Five transmit/receive single channel breast-shaped RF coils were constructed, and 3D phantom MRI was performed at 6.5 mT. The RF magnetic field homogeneity across the imaging volume and SNR were analyzed among the different coils. In vivo breast imaging was performed for the first time at 6.5 mT. Monte Carlo simulations were implemented to study the influence of copper wire on a proton beam, as well as the beam deflection at various static field strengths. Results: Our MOO method was validated - the observed field homogeneity, the relative ratio of attainable SNRs for all five breast coils, and the MRI signal from the chest agree with the simulations. In vivo breast and chest wall images acquired at ULF reveal good breast tissue contrast and can also visualize the heart. Finally, the results of this work indicate that a field strength of ∼50 mT with gradient strengths of ∼10 mT/m to minimize proton beam deflection, and the ability to achieve a ∼2 ´ 2 ´ 5 mm3 spatial resolution within few minutes are essential for making MRgPT clinically feasible. Conclusion: Our MOO method can be used to design breast coils that meet a wide range of imaging requirements.
- 20 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (5) , 1750-1765
Open AccessBreast Coil Optimization for Low Field MRI and Future MR-Guided Proton Therapy
Objective: Magnetic resonance imaging of the breast and the chest wall imaging was performed at ultra-low field (ULF) using optimal radiofrequency (RF) coil designs and, with an eye toward future application in MR-guided proton therapy (MRgPT), simulation studies of a pencil proton beam trajectory in low and ultra-low magnetic fields were performed. Methods: The primary focus in this study is the RF coil design, which is approached as a multi-objective optimization (MOO) problem and effectively solved using a Pareto optimality formalism. Our coil winding pattern algorithm simultaneously optimizes the magnetic field homogeneity of the coil, the attainable MRI signal-to-noise ratio (SNR), and the magnetic field drop-off into the chest wall for improved OAR imaging. Five transmit/receive single channel breast-shaped RF coils were constructed, and 3D phantom MRI was performed at 6.5 mT. The RF magnetic field homogeneity across the imaging volume and SNR were analyzed among the different coils. In vivo breast imaging was performed for the first time at 6.5 mT. Monte Carlo simulations were implemented to study the influence of copper wire on a proton beam, as well as the beam deflection at various static field strengths. Results: Our MOO method was validated - the observed field homogeneity, the relative ratio of attainable SNRs for all five breast coils, and the MRI signal from the chest agree with the simulations. In vivo breast and chest wall images acquired at ULF reveal good breast tissue contrast and can also visualize the heart. Finally, the results of this work indicate that a field strength of ∼50 mT with gradient strengths of ∼10 mT/m to minimize proton beam deflection, and the ability to achieve a ∼2 ´ 2 ´ 5 mm3 spatial resolution within few minutes are essential for making MRgPT clinically feasible. Conclusion: Our MOO method can be used to design breast coils that meet a wide range of imaging requirements.
- Open Access
Breast imaging with an ultra-low field MRI scanner: a pilot study
Breast cancer screening is necessary to reduce mortality due to undetected breast cancer. Current methods have limitations, and as a result many women forego regular screening. Magnetic resonance imaging (MRI) can overcome most of these limitations, but access to conventional MRI is not widely available for routine annual screening. Here, we used an MRI scanner operating at ultra-low field (ULF) to image the left breasts of 11 women (mean age, 35 years ±13 years) in the prone position. Three breast radiologists reviewed the imaging and were able to discern the breast outline and distinguish fibroglandular tissue (FGT) from intramammary adipose tissue. Additionally, the expert readers agreed on their assessment of the breast tissue pattern including fatty, scattered FGT, heterogeneous FGT, and extreme FGT. This preliminary work demonstrates that ULF breast MRI is feasible and may be a potential option for comfortable, widely deployable, and low-cost breast cancer diagnosis and screening.
Open AccessBreast imaging with an ultra-low field MRI scanner: a pilot study
Breast cancer screening is necessary to reduce mortality due to undetected breast cancer. Current methods have limitations, and as a result many women forego regular screening. Magnetic resonance imaging (MRI) can overcome most of these limitations, but access to conventional MRI is not widely available for routine annual screening. Here, we used an MRI scanner operating at ultra-low field (ULF) to image the left breasts of 11 women (mean age, 35 years ±13 years) in the prone position. Three breast radiologists reviewed the imaging and were able to discern the breast outline and distinguish fibroglandular tissue (FGT) from intramammary adipose tissue. Additionally, the expert readers agreed on their assessment of the breast tissue pattern including fatty, scattered FGT, heterogeneous FGT, and extreme FGT. This preliminary work demonstrates that ULF breast MRI is feasible and may be a potential option for comfortable, widely deployable, and low-cost breast cancer diagnosis and screening.