James Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
James Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Paul A. Webley
Department of Chemical and Biological Engineering Monash University Clayton Victoria Australia
3 shared publications - Thomas J. Hughes
Centre for Energy, School of Mechanical & Chemical Engineering, The University of Western Australia, Crawley, Western Australia 6009, Australia
3 shared publications - Changlong Wang
Department of Civil Engineering, Monash University, Melbourne, VIC, Australia
2 shared publications - Stuart D. C. Walsh
Department of Civil and Environmental Engineering, Monash University, Clayton, VIC 3800, Australia
2 shared publications Paul A. Webley
1 shared publicationThomas J. Hughes
1 shared publication
Latest Publications
- Open Access
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
The value of shaft furnace load flexibility in hydrogen-based steel making for mid and high grade ores: A case study in Australia
Australia is the world’s largest iron ore exporter and is well positioned to be a major producer of hydrogen-based direct reduced iron (DRI) and steel, given its vast iron ore deposits and abundant renewable energy. However, the mid-grade of the majority of Australian hematite makes the commercially demonstrated electric arc furnace (DRI-EAF) route unsuitable without extensive beneficiation. An alternative pathway using electric smelting furnace and basic oxygen furnace (DRI-ESF-BOF) may allow the direct use of high gangue ores. However, the intermittency of renewables presents a challenge to plants which rely on baseload power. New DRI shaft furnace (DRI-SF) technologies may allow load flexibility, reducing renewable capacity overbuild and firming. This study investigated the value of load flexibility (VoF) of the DRI-SF within an integrated steel plant, considering mid and high grade ore pathways. Enabling DRI-SF flexibility can reduce the levelised cost of steel (LCoS) by 25\% - 36\%, driven by reductions in solar, wind and hydrogen build-out. DRI-SF load flexibility allows deeper flexibility of the electrolyser, which become apparent during periods of renewable drought. As flexibility increases, dependence on hydrogen storage declines, with hot-briquetted iron (HBI) storage increasingly providing seasonal buffering. At full flexibility, cost parity can be achieved between the mid and high grade ore routes. Site selection significantly influences LCoS and VoF, with multiple regions were achieving LCoS as low as A\$1,100 per tonne. These findings have implications for Australia’s green steel strategy and the viability of mid and high grade ore pathways, and countries facing similar challenges in ore quality, renewable variability, and hydrogen-based industrial decarbonisation.
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThe value of shaft furnace load flexibility in hydrogen-based steel making for mid and high grade ores: A case study in Australia
Australia is the world’s largest iron ore exporter and is well positioned to be a major producer of hydrogen-based direct reduced iron (DRI) and steel, given its vast iron ore deposits and abundant renewable energy. However, the mid-grade of the majority of Australian hematite makes the commercially demonstrated electric arc furnace (DRI-EAF) route unsuitable without extensive beneficiation. An alternative pathway using electric smelting furnace and basic oxygen furnace (DRI-ESF-BOF) may allow the direct use of high gangue ores. However, the intermittency of renewables presents a challenge to plants which rely on baseload power. New DRI shaft furnace (DRI-SF) technologies may allow load flexibility, reducing renewable capacity overbuild and firming. This study investigated the value of load flexibility (VoF) of the DRI-SF within an integrated steel plant, considering mid and high grade ore pathways. Enabling DRI-SF flexibility can reduce the levelised cost of steel (LCoS) by 25\% - 36\%, driven by reductions in solar, wind and hydrogen build-out. DRI-SF load flexibility allows deeper flexibility of the electrolyser, which become apparent during periods of renewable drought. As flexibility increases, dependence on hydrogen storage declines, with hot-briquetted iron (HBI) storage increasingly providing seasonal buffering. At full flexibility, cost parity can be achieved between the mid and high grade ore routes. Site selection significantly influences LCoS and VoF, with multiple regions were achieving LCoS as low as A\$1,100 per tonne. These findings have implications for Australia’s green steel strategy and the viability of mid and high grade ore pathways, and countries facing similar challenges in ore quality, renewable variability, and hydrogen-based industrial decarbonisation.
- Open Access
- 28 July 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 256
Thermodynamic modelling of low fill levels in cryogenic storage tanks for application to liquid hydrogen maritime transport
- 28 July 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 256
Open AccessThermodynamic modelling of low fill levels in cryogenic storage tanks for application to liquid hydrogen maritime transport
- 23 March 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 62, 1273-1285
Thermodynamic modelling of pressurised storage and transportation of liquid hydrogen for maritime export
- 23 March 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 62, 1273-1285
Thermodynamic modelling of pressurised storage and transportation of liquid hydrogen for maritime export
- Open Access
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Thermal stratification and pressure evolution in large-scale liquid hydrogen storage
One of the barriers to large-scale liquid hydrogen (LH2) export is the high capital cost of high-performance insulation systems, requiring double-walled tanks to minimise boil-off rate (BOR). Unlike ground-based tanks, a commercial LH2 carrier is expected to utilise boil-off gas (BOG) for propulsion and onboard power. Sizing insulation to match steady-state BOR with BOG utilisation is not feasible, since steady-state heat transfer may not be achieved during a 2 – 3 week voyage. This is partly due to the large thermal mass of the tank relative to LH2. Furthermore, full utilisation of BOR for propulsion is not expected to occur until after 1 – 2 days when the ship is travelling on open seas. This study investigates transient pressure evolution within large spherical LH2 tanks using a lumped-mass analytical model, validated against experimental and CFD data. The model accounts for stratification within the liquid and vapour phases by considering wall boundary layer flow. For large tanks, a significantly greater pressure rise than would be expected for an isothermal, saturated mixture. Tank insulation is modelled in 2D to allow for non-uniform heat transfer, for various types of bulk insulation. Top-biased heating in particular is predicted to cause a greater pressure rise, driven by conduction heat transfer through transfer lines and support structures. The study also investigates induced mixing as a means to bring the liquid closer to an isothermal state, causing condensation in the vapour and lowering pressure. This could be used intermittently to delay the venting of BOG during the early stages of a voyage, reducing the thermal performance requirements for tank insulation.
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Open AccessThermal stratification and pressure evolution in large-scale liquid hydrogen storage
One of the barriers to large-scale liquid hydrogen (LH2) export is the high capital cost of high-performance insulation systems, requiring double-walled tanks to minimise boil-off rate (BOR). Unlike ground-based tanks, a commercial LH2 carrier is expected to utilise boil-off gas (BOG) for propulsion and onboard power. Sizing insulation to match steady-state BOR with BOG utilisation is not feasible, since steady-state heat transfer may not be achieved during a 2 – 3 week voyage. This is partly due to the large thermal mass of the tank relative to LH2. Furthermore, full utilisation of BOR for propulsion is not expected to occur until after 1 – 2 days when the ship is travelling on open seas. This study investigates transient pressure evolution within large spherical LH2 tanks using a lumped-mass analytical model, validated against experimental and CFD data. The model accounts for stratification within the liquid and vapour phases by considering wall boundary layer flow. For large tanks, a significantly greater pressure rise than would be expected for an isothermal, saturated mixture. Tank insulation is modelled in 2D to allow for non-uniform heat transfer, for various types of bulk insulation. Top-biased heating in particular is predicted to cause a greater pressure rise, driven by conduction heat transfer through transfer lines and support structures. The study also investigates induced mixing as a means to bring the liquid closer to an isothermal state, causing condensation in the vapour and lowering pressure. This could be used intermittently to delay the venting of BOG during the early stages of a voyage, reducing the thermal performance requirements for tank insulation.