SJShailesh Jain

Shailesh Jain

*This is an algorithmically generated author record based on publicly available information.

Shailesh Jain has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative efficacy and cytocompatibility of antimicrobial nanocoatings versus antibiotics on titanium dental implant surfaces

    by Maitreyi Ranjan, Shailesh Jain, Nikhil Prakash, Monika Sinha, Shabnam Chaudhary, Roli Singh

    Bacterial colonization resulting in peri-implantitis is a significant issue in dental implantology which results in an implant failure. Therefore, it is of interest to evaluate the antimicrobial efficacy and cytocompatibility of nanoparticle-based-coatings and conventional antibiotic-coatings on the titanium dental implant surfaces were compared. The determination of the cytocompatibility between human osteoblast-like cells (MG-63) was done in terms of MTT assay, cell proliferation and adhesion. AgNP coating was found to be more effective at antimicrobial efficacy against all bacteria studied (18.6±1.4 mm with S. aureus) than gentamicin (14.2±1.1 mm) and ZnO-NP (12.8±1.3 mm). Thus, data shows the nanoparticle-based coatings especially AgNPs have better antimicrobial effects with retained biocompatibility.

  • Open Access

    Immediate versus conventional loading implants with fixed prosthesis - A clinical and radiological study

    by Sahba Hassan, Dibya Kumari, Shailesh Jain, Nishant Gupta, Lalit Kumar, Surabhi Duggal

    The success of dental implants is influenced by the timing of prosthetic loading. Therefore, it is of interest to compare the clinical and radiological outcomes of immediate loading (IL) versus conventional loading (CL) of dental implants supporting fixed prostheses. Hence, a total of 30 patients were randomly assigned to either IL or CL groups. Clinical parameters such as implant stability (measured by Periotest), peri-implant soft tissue health and radiographic marginal bone loss (MBL) were evaluated over a 12-month period. Results indicated that both groups demonstrated high implant survival rates (96.6% IL vs 100% CL), with no statistically significant differences in MBL at 3, 6 and 12 months (p > 0.05). However, IL provided faster functional rehabilitation and patient satisfaction. Thus, we show the clinical viability of immediate loading protocols in appropriately selected cases, without compromising implant stability or bone levels.


  • Open Access

    Comparative evaluation of ferrule designs regarding fracture resistance about crowned anterior teeth using prefabricated post and composite core under direct loading: An in vitro study

    by Smritashree Baruah, Polysmita Ojah, Sangita Nath, Shailesh Jain, Nikhil P. Agnihotri, Surabhi Duggal

    The effect of different ferrule designs on the fracture resistance of endodontically treated maxillary central incisors. Caries-free maxillary central incisors were endodontically treated and divided into five groups (n=12) based on ferrule design. All teeth were restored with prefabricated glass fiber posts, composite cores, and metal crowns, then subjected to compressive loading using a universal testing machine. The group with a 2 mm circumferential ferrule showed the highest fracture resistance, while the group with no ferrule exhibited the lowest. Statistically significant differences were found among most groups, except between Group 2 and Group 3 (p=0.025).


  • Open Access

    Microbiological findings of dental implants among irradiated head and neck cancer patients

    by Himanshu Sharma, Surabhi Duggal, Sahba Hassan, Lalit Kumar, Shailesh Jain, Maitreyi Ranjan

    The microbiological profile surrounding healthy osseointegrated dental implants in patients treated with radiotherapy for head and neck cancer. Radiation therapy is known to alter the oral environment, potentially affecting peri-implant microbial colonization. Samples from irradiated patients with clinically healthy implants were analyzed for microbial composition. Thus, we show a distinct microbial signature compared to non-irradiated individuals, though without signs of peri-implant disease. These results highlight the importance of tailored monitoring protocols in post-radiotherapy implant care.

  • Open Access

    Comparative Analysis of Wear Resistance in 4D-Printed vs. 3D-Printed Dental Prosthetics

    by Sahba Hassan, Nikhil Prakash, Surabhi Duggal, Yogesh Garg, Shailesh Jain, Syed M. Ahamed

    Background: Advancements in additive manufacturing, particularly 3D printing, have revolutionized the field of dental prosthetics. Recently, 4D printing, which incorporates time-responsive materials, has emerged as a potential game-changer. This study aims to compare the wear resistance of 3D-printed and 4D-printed dental prosthetics to evaluate the clinical applicability of these innovative technologies. Materials and Methods: Dental prosthetics were fabricated using both 3D printing (polyetheretherketone, PEEK) and 4D printing (shape-memory polymer composites). A total of 40 prosthetics (20 per group) were subjected to wear simulation using a chewing simulator with a load of 50 N at 1 Hz for 100,000 cycles. Surface roughness (Ra) and volumetric loss (mm≥) were measured pre- and post-simulation using 3D laser scanning and confocal microscopy. Statistical analysis was performed using an independent t-test to compare the mean wear resistance between the two groups. Results: The 4D-printed prosthetics exhibited significantly lower volumetric loss (mean: 0.34 ± 0.08 mm≥) compared to the 3D-printed prosthetics (mean: 0.76 ± 0.12 mm≥, P < 0.01). Surface roughness analysis revealed a smaller increase in Ra for 4D-printed prosthetics (from 0.22 ± 0.03 μm to 0.28 ± 0.05 μm) compared to 3D-printed prosthetics (from 0.24 ± 0.04 μm to 0.41 ± 0.06 μm, P < 0.01). Conclusion: The study demonstrates that 4D-printed dental prosthetics possess superior wear resistance compared to 3D-printed prosthetics, highlighting their potential for enhanced longevity and clinical performance in restorative dentistry. Future studies should focus on long-term in vivo evaluations and material optimization to further validate these findings.


  • Open Access

    Evaluation of Dimensional Accuracy and Feasibility of an in House Desktop Printer for Preoperative Planning and Precontouring of Implants for Craniomaxillofacial Surgery

    by Shahana Parveen, Dinesh Kumar, Mausumi Iqbal, Ayushi Mishra, Yogesh Garg, Shailesh Jain

    Background: 3D printing soon after its inception has spread globally as a useful tool in preoperative planning. Thus, this study aims to evaluate the accuracy and efficacy of the 3D printed models in preoperative surgical planning and prebending of implant adaptation for craniomaxillofacial surgery. Methods: A prospective study including 10 patients requiring complex maxillofacial management. A preoperative CBCT/CT scan of the patient was obtained in DICOM format was obtained, and data were converted to STL format by using Mimics software. Time taken for the surgery and amount of blood loss were also recorded. All patients were followed up at intervals of 1 week, 1 month, and 3 months for assessing facial symmetry. Results: Average time and blood loss during the operative procedure that was observed were 217.5 min and 405 mL, respectively. Evaluation of facial symmetry showed good facial symmetry (90%) and showed fair facial symmetry (10%), and there was the restoration of facial symmetry to a preoperative premorbid state. Conclusions: The present study suggests the advantages and outcomes of 3D printing technology surpass the limitations and thus recommends the use of a 3D printed model for preoperative planning for minor as well as major and complex craniomaxillofacial surgery.

  • Open Access

    Association between Age of Menopause and Thickness of Crestal Cortical Bone at Dental Implant Site: A Cross-Sectional Observational Study

    by Dinesh Kumar, Sahba Hassan, Madhu S. Ratre, Shailesh Jain, Rajesh K. Gupta, Nikhil P. Agnihotri

    Objective: Menopause, the natural biological transition marking the end of a woman’s reproductive years. The study’s main objective is to find an association between menopause age and the thickness of crystal cortical bone at the dental implant site. Methodology: Data were collected from 155 postmenopausal women who have undergone dental implant placement. Results: In the early menopause group (≤45 years), the average bone thickness was 4.2 ± 1.0 mm at the mesial, 3.8 ± 0.9 mm at the mid, and 4.1 ± 1.2 mm at the distal site, with an overall average of 4.0 ± 1.1 mm. In contrast, the late menopause group (>45 years) had an average bone thickness of 3.3 ± 1.1 mm at the mesial, 3.1 ± 1.0 mm at the mid, and 3.2 ± 1.1 mm at the distal site, with an overall average of 3.2 ± 1.0 mm. Conclusion: It is concluded that the age of menopause plays a significant role in determining the thickness of the crestal cortical bone at dental implant sites in postmenopausal women.


  • Open Access

    Microbial adherence and surface roughness of denture base materials: An in vitro study

    by Lalit Kumar, Suranjana Sen, Deepali Agarwal, Megha Gupta, Khadija Anwaar, Shailesh Jain

    Implant-supported overdentures have become a widely accepted treatment modality for edentulous patients, offering enhanced retention, stability and comfort compared to conventional complete dentures. Hence, a total of 78 standardized specimens were fabricated and divided into three groups (n = 26 each): Group A (heat-cured PMMA), Group B (CAD/CAM milled resin) and Group C (3D-printed resin). Group B exhibited the lowest surface roughness (0.62 ą 0.12 μm) and microbial adherence (0.41 ą 0.09 OD), followed by Group C (1.25 ą 0.18 μm Ra; 0.68 ą 0.12 OD), while Group A showed the highest values (1.82 ą 0.23 μm Ra; 0.91 ą 0.15 OD). All intergroup comparisons were statistically significant (p < 0.001). A strong positive correlation (r = 0.86, p < 0.001) was observed between surface roughness and microbial adherence. It is concluded that CAD/CAM milled resin offers superior surface smoothness and reduced microbial adherence compared to heat-cured PMMA and 3D-printed resins.


  • Open Access

    Retention and marginal bone loss in attachment systems for implant retained overdentures

    by Surabhi Duggal, Sahba Hassan, Khadija Anwaar, Yogesh Garg, Shailesh Jain

    Comparison of retention and marginal bone loss of ball, bar and locator attachment systems for implant retained over dentures it is of interest. Hence, related data were collected from 75 patients. Retention was highest for the bar system, while the locator and ball systems exhibited moderate and significant reductions. The bar attachment system outperformed ball and locator systems in retention, marginal bone preservation and patient satisfaction, making it the most effective option for implant-retained over dentures.

  • Open Access

    Study of Prevalence of Gastritis Caused by H. pylori and Correlation of Urease Test with Serology (ELISA) Test

    by Maitreyi Ranjan, Hany Hameed, Shailesh Jain, Yogesh Garg, Roli Singh, Manjulika Tyagi, Romesh Jain

    Introduction: H. pylori are a pathogen of global importance. Gram-negative curved flagellate bacilli are implicated as one of the most trivial complaints of and are associated with peptic ulcer disease gastritis ulcer and gastric malignancy. This study was performed to find out the prevalence of Helicobacter pylori (H. pylori) infection in patients presenting the symptoms related with gastritis with or without chemically known peptic ulcer. Materials and Methods: The study was undertaken with the help of the Christensen and quotes urease test on endoscopic biopsy specimen and correlated with the detection of immunoglobulin IgG in the serum against H. pylori by an ELISA technique. Results: A total of 67 cases were analyzed in which 29 (43%) cases were positive for H. pylori. The endoscopic findings of acid peptic diseases show 21 (31.4%) cases of stomach ulcer, and 3 (4.5%) have esophagitis, whereas 43 (64.1%) have nonulcer dyspepsia. There is strong positive association between the urease tesr and ELISA test. Conclusion: The urease test is a quick and inexpensive test with high specificity and sensitivity, but since it is an invasive test, it has reduced patient compliance.