Khadija Anwaar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Khadija Anwaar has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Shailesh Jain
Department of Prosthodontics and Crown & Bridge, Bhojia Dental College, Baddi, Himachal Pradesh, India
2 shared publications Deepali Agarwal
Department of Microbiology, Institute of Dental Studies and Technology, Kadrabad, Modinagar, Uttar Pradesh, India
1 shared publication- Lalit Kumar
Prosthodontics, Medical Officer (Dental) CHC Chandi, District Solan, Himachal Pradesh, India
1 shared publication - Megha Gupta
Department of Oral and Maxillofacial Surgery, Maharishi Markandeshwar College of Dental Sciences and Research, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, Haryana, India
1 shared publication Sahba Hassan
1 shared publication- Surabhi Duggal
Department of Prosthodontics and Crown & Bridge, School of Dental Sciences, Sharda University, Greater Noida, Uttar Pradesh, India
1 shared publication
Latest Publications
- Open Access
- 31 May 2025
- Published by Biomedical Informatics in Bioinformation
- Vol. 21 (05) , 1187-1190
Microbial adherence and surface roughness of denture base materials: An in vitro study
Implant-supported overdentures have become a widely accepted treatment modality for edentulous patients, offering enhanced retention, stability and comfort compared to conventional complete dentures. Hence, a total of 78 standardized specimens were fabricated and divided into three groups (n = 26 each): Group A (heat-cured PMMA), Group B (CAD/CAM milled resin) and Group C (3D-printed resin). Group B exhibited the lowest surface roughness (0.62 ą 0.12 μm) and microbial adherence (0.41 ą 0.09 OD), followed by Group C (1.25 ą 0.18 μm Ra; 0.68 ą 0.12 OD), while Group A showed the highest values (1.82 ą 0.23 μm Ra; 0.91 ą 0.15 OD). All intergroup comparisons were statistically significant (p < 0.001). A strong positive correlation (r = 0.86, p < 0.001) was observed between surface roughness and microbial adherence. It is concluded that CAD/CAM milled resin offers superior surface smoothness and reduced microbial adherence compared to heat-cured PMMA and 3D-printed resins.
- 31 May 2025
- Published by Biomedical Informatics in Bioinformation
- Vol. 21 (05) , 1187-1190
Open AccessMicrobial adherence and surface roughness of denture base materials: An in vitro study
Implant-supported overdentures have become a widely accepted treatment modality for edentulous patients, offering enhanced retention, stability and comfort compared to conventional complete dentures. Hence, a total of 78 standardized specimens were fabricated and divided into three groups (n = 26 each): Group A (heat-cured PMMA), Group B (CAD/CAM milled resin) and Group C (3D-printed resin). Group B exhibited the lowest surface roughness (0.62 ą 0.12 μm) and microbial adherence (0.41 ą 0.09 OD), followed by Group C (1.25 ą 0.18 μm Ra; 0.68 ą 0.12 OD), while Group A showed the highest values (1.82 ą 0.23 μm Ra; 0.91 ą 0.15 OD). All intergroup comparisons were statistically significant (p < 0.001). A strong positive correlation (r = 0.86, p < 0.001) was observed between surface roughness and microbial adherence. It is concluded that CAD/CAM milled resin offers superior surface smoothness and reduced microbial adherence compared to heat-cured PMMA and 3D-printed resins.
- Open Access
- 31 March 2025
- Published by Biomedical Informatics in Bioinformation
- Vol. 21 (03) , 485-488
Retention and marginal bone loss in attachment systems for implant retained overdentures
Comparison of retention and marginal bone loss of ball, bar and locator attachment systems for implant retained over dentures it is of interest. Hence, related data were collected from 75 patients. Retention was highest for the bar system, while the locator and ball systems exhibited moderate and significant reductions. The bar attachment system outperformed ball and locator systems in retention, marginal bone preservation and patient satisfaction, making it the most effective option for implant-retained over dentures.
- 31 March 2025
- Published by Biomedical Informatics in Bioinformation
- Vol. 21 (03) , 485-488
Open AccessRetention and marginal bone loss in attachment systems for implant retained overdentures
Comparison of retention and marginal bone loss of ball, bar and locator attachment systems for implant retained over dentures it is of interest. Hence, related data were collected from 75 patients. Retention was highest for the bar system, while the locator and ball systems exhibited moderate and significant reductions. The bar attachment system outperformed ball and locator systems in retention, marginal bone preservation and patient satisfaction, making it the most effective option for implant-retained over dentures.