Erik Larsson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Erik Larsson has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Johan Gustafsson
Lund University
3 shared publications - Anna Stenvall
Radiation Physics, Department of Haematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden
1 shared publication Elias Nilsson
Radiation Physics, Department of Haematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden
1 shared publication- Irma Cerić Andelius
Radiation Physics, Department of Haematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden.
1 shared publication Katarina Sjögreen Gleisner
Medical Radiation Physics, Lund, Lund University, Lund, Sweden
1 shared publication- Katarina Sjögreen Gleisner
Medical Radiation Physics, Lund, Lund University, Lund, Sweden
1 shared publication
Latest Publications
- Open Access
- 3 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (21) , 215016
Dimensionality reduction for partial-volume correction in quantitative SPECT
Objective . The aim of this paper is to develop a method for region-based post-reconstruction partial-volume correction (PVC) of single photon emission computed tomography (SPECT) images, which explicitly estimates the mean activity concentration in regions without assuming strict intra-regional uniformity. Approach . PVC was applied to 177 Lu-SPECT images obtained from the simulation of eight anthropomorphic phantoms as well as two example patients. Both sets of data were reconstructed using OS-EM with ten subsets and up to 40 iterations, including compensation for attenuation, scatter, and spatial resolution. Reconstructed images were deconvolved using the van Cittert algorithm and Lucy–Richardson algorithm, both implemented on images represented as standard cuboid voxels or as regional voxels, consisting of regions defined from whole-image segmentation. Methods embedding regional voxels were applied both assuming region-wise uniform activity concentration and incorporating perturbations in the form of cosine series to relax the uniformity assumption. For comparison, images were also processed with the iterative Yang method and MIRD recovery coefficients. Evaluation was performed with respect to the estimated activity concentration for kidneys, spleen, and tumours, as well as the total activity in the images. Main results . Mean activity-concentration errors prior to PVC were (−22.6 ± 11.5) %, (−13.8 ± 2.1) %, and (−7.4 ± 2.8) % for tumours, kidneys, and spleen, respectively. Region-perturbed van Cittert deconvolution with order 4 reduced these errors to (2.3 ± 7.7) %, (0.3 ± 2.2) %, and (4.0 ± 1.6) % while the errors for region-perturbed Lucy-Richardson deconvolution of order 4 were (0.3 ± 8.0) %, (0.0 ± 1.6) %, (2.6 ± 0.5) %. Corresponding results for the iterative Yang method were (2.8 ± 21) %, (−0.3 ± 2.1) %, and (3.8 ± 2.4) % and using MIRD recovery coefficients (−5.0 ± 14.2) %, (−7.1 ± 1.9) %, and (−0.6 ± 3.1) %. Significance . Region-based PVC improves the accuracy of quantitative SPECT, and the inclusion of cosine perturbations allows for a gradual relaxation of the uniformity assumption.
- 3 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (21) , 215016
Open AccessDimensionality reduction for partial-volume correction in quantitative SPECT
Objective . The aim of this paper is to develop a method for region-based post-reconstruction partial-volume correction (PVC) of single photon emission computed tomography (SPECT) images, which explicitly estimates the mean activity concentration in regions without assuming strict intra-regional uniformity. Approach . PVC was applied to 177 Lu-SPECT images obtained from the simulation of eight anthropomorphic phantoms as well as two example patients. Both sets of data were reconstructed using OS-EM with ten subsets and up to 40 iterations, including compensation for attenuation, scatter, and spatial resolution. Reconstructed images were deconvolved using the van Cittert algorithm and Lucy–Richardson algorithm, both implemented on images represented as standard cuboid voxels or as regional voxels, consisting of regions defined from whole-image segmentation. Methods embedding regional voxels were applied both assuming region-wise uniform activity concentration and incorporating perturbations in the form of cosine series to relax the uniformity assumption. For comparison, images were also processed with the iterative Yang method and MIRD recovery coefficients. Evaluation was performed with respect to the estimated activity concentration for kidneys, spleen, and tumours, as well as the total activity in the images. Main results . Mean activity-concentration errors prior to PVC were (−22.6 ± 11.5) %, (−13.8 ± 2.1) %, and (−7.4 ± 2.8) % for tumours, kidneys, and spleen, respectively. Region-perturbed van Cittert deconvolution with order 4 reduced these errors to (2.3 ± 7.7) %, (0.3 ± 2.2) %, and (4.0 ± 1.6) % while the errors for region-perturbed Lucy-Richardson deconvolution of order 4 were (0.3 ± 8.0) %, (0.0 ± 1.6) %, (2.6 ± 0.5) %. Corresponding results for the iterative Yang method were (2.8 ± 21) %, (−0.3 ± 2.1) %, and (3.8 ± 2.4) % and using MIRD recovery coefficients (−5.0 ± 14.2) %, (−7.1 ± 1.9) %, and (−0.6 ± 3.1) %. Significance . Region-based PVC improves the accuracy of quantitative SPECT, and the inclusion of cosine perturbations allows for a gradual relaxation of the uniformity assumption.
- Open Access
- 14 June 2026
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
Evaluation of modified window-based scatter compensation in quantitative 177Lu-SPECT for a ring-configured CZT SPECT-CT
Background: The aim was to evaluate bias and precision for 177 Lu-activity-quantification using window-based scatter compensation in a ring-configured CZT gamma camera (StarGuide™, GE HealthCare). This paper extends a previous study by applying modified scatter compensation (MSC) methods introduced with the StarGuidePlus upgrade. The modified methods account for contamination of scatter windows by primary photons due to tailing. Whilst the original compensation addressed tailing in the 208 keV peak only, the upgrade extends the concept to the 113 keV peak and enables the estimated primary signal in the scatter windows to be included to the measured projections (MSC + P). Methods: Listmode-data for a NEMA phantom and anthropomorphic phantom were reframed to accommodate the updated settings for MSC and MSC + P. Reconstruction was performed using OS-EM (two to 30 iterations, 10 subsets) with compensation for attenuation, scatter (DEW/TEW, MSC and MSC + P), spatial resolution, and penetration at 208 keV. Volumes-of-interest following the manufacturer-specified sphere sizes were defined and activity-concentration was quantified for each sphere and the total phantom activity across six (10 min) time-frames. Bias was evaluated with mean relative error and precision with coefficient of variation (CV). Results: Imaging at 208 keV generally results in similar activity concentrations and total activity estimates for MSC and MSC + P (mean relative error: − 24.8 to − 23.4%, CV: 0.6 and 0.7% for the larges sphere). For 113 keV, a slightly better precision is obtained for MSC and MSC + P (mean relative error: − 15.4 and − 21.5%, CV: 0.6 and 0.7% for the largest sphere in the NEMA phantom) but a larger bias compared with TEW (mean relative error − 7.1%, CV 0.8%). The major difference is for total activity where the MSC and MSC + P decrease bias compared to TEW (5 and 4% versus 21% for 113 keV in the NEMA phantom). Conclusions: The improvement in activity-concentration accuracy in regard to bias and precision is modest in small-volume high activity-concentration regions. However, the findings suggest potential value in preservation of total activity for both MSC and MSC + P.
- 14 June 2026
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
Open AccessEvaluation of modified window-based scatter compensation in quantitative 177Lu-SPECT for a ring-configured CZT SPECT-CT
Background: The aim was to evaluate bias and precision for 177 Lu-activity-quantification using window-based scatter compensation in a ring-configured CZT gamma camera (StarGuide™, GE HealthCare). This paper extends a previous study by applying modified scatter compensation (MSC) methods introduced with the StarGuidePlus upgrade. The modified methods account for contamination of scatter windows by primary photons due to tailing. Whilst the original compensation addressed tailing in the 208 keV peak only, the upgrade extends the concept to the 113 keV peak and enables the estimated primary signal in the scatter windows to be included to the measured projections (MSC + P). Methods: Listmode-data for a NEMA phantom and anthropomorphic phantom were reframed to accommodate the updated settings for MSC and MSC + P. Reconstruction was performed using OS-EM (two to 30 iterations, 10 subsets) with compensation for attenuation, scatter (DEW/TEW, MSC and MSC + P), spatial resolution, and penetration at 208 keV. Volumes-of-interest following the manufacturer-specified sphere sizes were defined and activity-concentration was quantified for each sphere and the total phantom activity across six (10 min) time-frames. Bias was evaluated with mean relative error and precision with coefficient of variation (CV). Results: Imaging at 208 keV generally results in similar activity concentrations and total activity estimates for MSC and MSC + P (mean relative error: − 24.8 to − 23.4%, CV: 0.6 and 0.7% for the larges sphere). For 113 keV, a slightly better precision is obtained for MSC and MSC + P (mean relative error: − 15.4 and − 21.5%, CV: 0.6 and 0.7% for the largest sphere in the NEMA phantom) but a larger bias compared with TEW (mean relative error − 7.1%, CV 0.8%). The major difference is for total activity where the MSC and MSC + P decrease bias compared to TEW (5 and 4% versus 21% for 113 keV in the NEMA phantom). Conclusions: The improvement in activity-concentration accuracy in regard to bias and precision is modest in small-volume high activity-concentration regions. However, the findings suggest potential value in preservation of total activity for both MSC and MSC + P.
- 30 March 2024
- Published by Elsevier in Physica Medica
- Vol. 120, 103335
Kidney dosimetry in [177Lu]Lu-DOTA-TATE therapy based on multiple small VOIs
- 30 March 2024
- Published by Elsevier in Physica Medica
- Vol. 120, 103335
Kidney dosimetry in [177Lu]Lu-DOTA-TATE therapy based on multiple small VOIs