Abstract
Objective . The aim of this paper is to develop a method for region-based post-reconstruction partial-volume correction (PVC) of single photon emission computed tomography (SPECT) images, which explicitly estimates the mean activity concentration in regions without assuming strict intra-regional uniformity. Approach . PVC was applied to 177 Lu-SPECT images obtained from the simulation of eight anthropomorphic phantoms as well as two example patients. Both sets of data were reconstructed using OS-EM with ten subsets and up to 40 iterations, including compensation for attenuation, scatter, and spatial resolution. Reconstructed images were deconvolved using the van Cittert algorithm and Lucy–Richardson algorithm, both implemented on images represented as standard cuboid voxels or as regional voxels, consisting of regions defined from whole-image segmentation. Methods embedding regional voxels were applied both assuming region-wise uniform activity concentration and incorporating perturbations in the form of cosine series to relax the uniformity assumption. For comparison, images were also processed with the iterative Yang method and MIRD recovery coefficients. Evaluation was performed with respect to the estimated activity concentration for kidneys, spleen, and tumours, as well as the total activity in the images. Main results . Mean activity-concentration errors prior to PVC were (−22.6 ± 11.5) %, (−13.8 ± 2.1) %, and (−7.4 ± 2.8) % for tumours, kidneys, and spleen, respectively. Region-perturbed van Cittert deconvolution with order 4 reduced these errors to (2.3 ± 7.7) %, (0.3 ± 2.2) %, and (4.0 ± 1.6) % while the errors for region-perturbed Lucy-Richardson deconvolution of order 4 were (0.3 ± 8.0) %, (0.0 ± 1.6) %, (2.6 ± 0.5) %. Corresponding results for the iterative Yang method were (2.8 ± 21) %, (−0.3 ± 2.1) %, and (3.8 ± 2.4) % and using MIRD recovery coefficients (−5.0 ± 14.2) %, (−7.1 ± 1.9) %, and (−0.6 ± 3.1) %. Significance . Region-based PVC improves the accuracy of quantitative SPECT, and the inclusion of cosine perturbations allows for a gradual relaxation of the uniformity assumption.Keywords
Funding Information
- Mrs Berta Kamprad’s Foundation (FBKS-2024-7-583)
- Region Skåne
- Swedish Cancer Society (243785Pj01H)
This publication has 43 references indexed in Scilit:
- Direct estimation of activity concentration in regional voxels with application to 177 Lu peptide receptor radionuclide therapyMedical Physics, 2026
- Impact of partial volume correction on radiomics reproducibility in theranostic SPECT/CT imagingMedical Physics, 2026
- Artifact‐free partial volume correction for 177 Lu‐PSMA SPECTMedical Physics, 2025
- Attention-based deep neural network for partial volume correction in brain 18F-FDG PET imagingPhysica Medica, 2024
- A novel model-based equation for size dependent mean recovery coefficients for spheres and other shapesPhysica Medica, 2023
- DblurDoseNet: A deep residual learning network for voxel radionuclide dosimetry compensating for single‐photon emission computerized tomography imaging resolutionMedical Physics, 2021
- A method for tumor dosimetry based on hybrid planar‐SPECT/CT images and semiautomatic segmentationMedical Physics, 2018
- A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncologyPhysics in Medicine & Biology, 2012
- A Monte Carlo program for the simulation of scintillation camera characteristicsComputer Methods and Programs in Biomedicine, 1989
- An iterative technique for the rectification of observed distributionsThe Astronomical Journal, 1974