Luigi Pannone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luigi Pannone has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Carlo de Asmundis
Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Heart Rhythm Research Brussels, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
4 shared publications - Mark La Meir
Cardiac Surgery Department, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, 1090 Brussels, Belgium
4 shared publications - Gian-Battista Chierchia
Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium
3 shared publications - Ali Gharaviri
Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Heart Rhythm Research Brussels, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium
2 shared publications - Andrea Maria Paparella
Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Heart Rhythm Research Brussels, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium
2 shared publications - Domenico Giovanni Della Rocca
Department of Ophthalmology, University Hospital Brussels, Laarbeeklaan 101, 1090 Jette, Belgium
2 shared publications
Latest Publications
- Open Access
- 28 August 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 924
Impact of Disinfection and Sterilization on 3D-Printing Resin Performance for Surgical Guides in Cardiac Ablation Surgery
Patient-tailored, 3D-printed surgical guides offer significant potential to improve precision and therapeutic efficacy in cardiac ablation surgery. However, reliable post-sterilization material performance presents a critical yet underexplored barrier to clinical adoption. This study investigates how disinfection and sterilization impact the mechanical and thermal properties of photopolymer resins. Specimens from two 3D-printing resins (Bioflex A80 MB™, 3Dresyns; MED625FLX™, Stratasys) were treated with four combinations of disinfection techniques (low-temperature manual cleaning; high-temperature machine washing) and sterilization techniques (H2O2 vs. autoclaving). We assessed post-sterilization properties by mechanical (material integrity, bending tests), thermal (differential scanning calorimetry, thermogravimetric analysis), and viscoelastic (dynamic mechanical analysis) studies. Statistical analysis was performed using one-way ANOVA with Bonferroni post hoc tests (α = 0.05). From this preliminary study, we conclude that MED625FLX maintains integrity and flexibility across all tested disinfection and sterilization methods. Bioflex A80 MB is only suitable for low-temperature disinfection–sterilization, as high-temperature treatments cause surface cracking. Neither resin is appropriate for cryogenic conditions due to the risk of brittleness. Further research into post-sterilization properties is essential to ensure the safety and clinical reliability of these materials in cardiac procedures.
- 28 August 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 924
Open AccessImpact of Disinfection and Sterilization on 3D-Printing Resin Performance for Surgical Guides in Cardiac Ablation Surgery
Patient-tailored, 3D-printed surgical guides offer significant potential to improve precision and therapeutic efficacy in cardiac ablation surgery. However, reliable post-sterilization material performance presents a critical yet underexplored barrier to clinical adoption. This study investigates how disinfection and sterilization impact the mechanical and thermal properties of photopolymer resins. Specimens from two 3D-printing resins (Bioflex A80 MB™, 3Dresyns; MED625FLX™, Stratasys) were treated with four combinations of disinfection techniques (low-temperature manual cleaning; high-temperature machine washing) and sterilization techniques (H2O2 vs. autoclaving). We assessed post-sterilization properties by mechanical (material integrity, bending tests), thermal (differential scanning calorimetry, thermogravimetric analysis), and viscoelastic (dynamic mechanical analysis) studies. Statistical analysis was performed using one-way ANOVA with Bonferroni post hoc tests (α = 0.05). From this preliminary study, we conclude that MED625FLX maintains integrity and flexibility across all tested disinfection and sterilization methods. Bioflex A80 MB is only suitable for low-temperature disinfection–sterilization, as high-temperature treatments cause surface cracking. Neither resin is appropriate for cryogenic conditions due to the risk of brittleness. Further research into post-sterilization properties is essential to ensure the safety and clinical reliability of these materials in cardiac procedures.
- Open Access
- 19 August 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (8) , 313
Hybrid Ablation in Atrial Fibrillation: Bridging Mechanistic Understanding and Clinical Practice
Atrial fibrillation (AF), the most prevalent sustained cardiac arrhythmia, poses a significant burden on global morbidity and healthcare expenditure. Although endocardial catheter ablation and surgical ablation are established therapeutic strategies, each exhibits inherent limitations in achieving comprehensive substrate modification. Hybrid ablation therapy, integrating both endocardial and epicardial approaches, aims to overcome these limitations by enabling the more extensive and transmural targeting of arrhythmogenic foci and the complex atrial substrate. This review synthesizes the electrophysiological basis and mechanistic rationale underpinning hybrid AF ablation, highlighting its potential for an enhanced efficacy compared to isolated techniques. Furthermore, it introduces the emerging paradigm of three-dimensional ablation within this evolving field.
- 19 August 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (8) , 313
Open AccessHybrid Ablation in Atrial Fibrillation: Bridging Mechanistic Understanding and Clinical Practice
Atrial fibrillation (AF), the most prevalent sustained cardiac arrhythmia, poses a significant burden on global morbidity and healthcare expenditure. Although endocardial catheter ablation and surgical ablation are established therapeutic strategies, each exhibits inherent limitations in achieving comprehensive substrate modification. Hybrid ablation therapy, integrating both endocardial and epicardial approaches, aims to overcome these limitations by enabling the more extensive and transmural targeting of arrhythmogenic foci and the complex atrial substrate. This review synthesizes the electrophysiological basis and mechanistic rationale underpinning hybrid AF ablation, highlighting its potential for an enhanced efficacy compared to isolated techniques. Furthermore, it introduces the emerging paradigm of three-dimensional ablation within this evolving field.
- Open Access
- 9 April 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (4) , 145
A Hybrid Minimally Invasive Atrial Fibrillation Ablation Procedure Using Unilateral Thoracoscopy and Endocardial Pulsed Field Ablation: An Early Feasibility Study
(1) Objective: To examine the efficiency and efficacy of using endovascular mapping and pulsed field ablation in the setting of a hybrid video-assisted thoracoscopic atrial fibrillation (AF) ablation procedure. (2) Methods: Eleven consecutive patients underwent hybrid video-assisted thoracoscopic epicardial ablation and left atrial appendage exclusion followed by endocardial ablation using pulsed field ablation energy. The completeness of epicardial and endocardial lesion sets were assessed using 3D electro-anatomical mapping. (3) Results: Left atrial appendage (LAA) exclusion and durable pulmonary vein isolation (PVI) and posterior wall isolation (PWI) were achieved in all patients. The endovascular part of the necessary lesion set using PFA energy was successful in 100% of the patients. All patients remained in SR during the 12-month follow-up period. (4) Conclusions: Our study confirms the feasibility of using endovascular pulsed field ablation to complete previously performed epicardial lesion sets during the hybrid AF ablation procedures, without extending the procedure time or increasing the risk of complications.
- 9 April 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (4) , 145
Open AccessA Hybrid Minimally Invasive Atrial Fibrillation Ablation Procedure Using Unilateral Thoracoscopy and Endocardial Pulsed Field Ablation: An Early Feasibility Study
(1) Objective: To examine the efficiency and efficacy of using endovascular mapping and pulsed field ablation in the setting of a hybrid video-assisted thoracoscopic atrial fibrillation (AF) ablation procedure. (2) Methods: Eleven consecutive patients underwent hybrid video-assisted thoracoscopic epicardial ablation and left atrial appendage exclusion followed by endocardial ablation using pulsed field ablation energy. The completeness of epicardial and endocardial lesion sets were assessed using 3D electro-anatomical mapping. (3) Results: Left atrial appendage (LAA) exclusion and durable pulmonary vein isolation (PVI) and posterior wall isolation (PWI) were achieved in all patients. The endovascular part of the necessary lesion set using PFA energy was successful in 100% of the patients. All patients remained in SR during the 12-month follow-up period. (4) Conclusions: Our study confirms the feasibility of using endovascular pulsed field ablation to complete previously performed epicardial lesion sets during the hybrid AF ablation procedures, without extending the procedure time or increasing the risk of complications.
- Open Access
- 15 April 2024
- Published by MDPI AG in Biomedicines
- Vol. 12 (4) , 869
Advancing Surgical Arrhythmia Ablation: Novel Insights on 3D Printing Applications and Two Biocompatible Materials
To date, studies assessing the safety profile of 3D printing materials for application in cardiac ablation are sparse. Our aim is to evaluate the safety and feasibility of two biocompatible 3D printing materials, investigating their potential use for intra-procedural guides to navigate surgical cardiac arrhythmia ablation. Herein, we 3D printed various prototypes in varying thicknesses (0.8 mm–3 mm) using a resin (MED625FLX) and a thermoplastic polyurethane elastomer (TPU95A). Geometrical testing was performed to assess the material properties pre- and post-sterilization. Furthermore, we investigated the thermal propagation behavior beneath the 3D printing materials during cryo-energy and radiofrequency ablation using an in vitro wet-lab setup. Moreover, electron microscopy and Raman spectroscopy were performed on biological tissue that had been exposed to the 3D printing materials to assess microparticle release. Post-sterilization assessments revealed that MED625FLX at thicknesses of 1 mm, 2.5 mm, and 3 mm, along with TPU95A at 1 mm and 2.5 mm, maintained geometrical integrity. Thermal analysis revealed that material type, energy source, and their factorial combination with distance from the energy source significantly influenced the temperatures beneath the 3D-printed material. Electron microscopy revealed traces of nitrogen and sulfur underneath the MED625FLX prints (1 mm, 2.5 mm) after cryo-ablation exposure. The other samples were uncontaminated. While Raman spectroscopy did not detect material release, further research is warranted to better understand these findings for application in clinical settings.
- 15 April 2024
- Published by MDPI AG in Biomedicines
- Vol. 12 (4) , 869
Open AccessAdvancing Surgical Arrhythmia Ablation: Novel Insights on 3D Printing Applications and Two Biocompatible Materials
To date, studies assessing the safety profile of 3D printing materials for application in cardiac ablation are sparse. Our aim is to evaluate the safety and feasibility of two biocompatible 3D printing materials, investigating their potential use for intra-procedural guides to navigate surgical cardiac arrhythmia ablation. Herein, we 3D printed various prototypes in varying thicknesses (0.8 mm–3 mm) using a resin (MED625FLX) and a thermoplastic polyurethane elastomer (TPU95A). Geometrical testing was performed to assess the material properties pre- and post-sterilization. Furthermore, we investigated the thermal propagation behavior beneath the 3D printing materials during cryo-energy and radiofrequency ablation using an in vitro wet-lab setup. Moreover, electron microscopy and Raman spectroscopy were performed on biological tissue that had been exposed to the 3D printing materials to assess microparticle release. Post-sterilization assessments revealed that MED625FLX at thicknesses of 1 mm, 2.5 mm, and 3 mm, along with TPU95A at 1 mm and 2.5 mm, maintained geometrical integrity. Thermal analysis revealed that material type, energy source, and their factorial combination with distance from the energy source significantly influenced the temperatures beneath the 3D-printed material. Electron microscopy revealed traces of nitrogen and sulfur underneath the MED625FLX prints (1 mm, 2.5 mm) after cryo-ablation exposure. The other samples were uncontaminated. While Raman spectroscopy did not detect material release, further research is warranted to better understand these findings for application in clinical settings.