Ruoyu Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ruoyu Wang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Baiqiang Yin
Hefei University of Technology
5 shared publications - Bing Li
Hefei University of Technology
4 shared publications - Lei Zuo
Hefei University of Technology
4 shared publications - Zhen Cheng
Hefei University of Technology
3 shared publications - Chengwei Ding
Hefei University of Technology
2 shared publications - Dalong Cheng
Electrical and Automation Engineering, Hefei University of Technology, Hefei, China
2 shared publications
Latest Publications
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (4) , 861-871
Crosstalk Suppression Method at the End of Multiconductor Transmission Lines Based on Crosstalk Factor Theory
Considering the complexity and difficulty of solving the size of crosstalk capability of different transmission lines to each other in the signal transmission process of multi-conductor transmission lines, this paper proposes a new experimental method to determine the crosstalk capability of each transmission line to the other transmission lines on the basis of the theory of multi-conductor transmission lines, and names this crosstalk capability as crosstalk factor as the theoretical support for the selection of the optimal phase combination of excitation source signals of each transmission line to realize a better crosstalk suppression effect on the target transmission line. To realize better crosstalk suppression effect on the target transmission line. Through the comprehensive theoretical analysis of the influence factors of crosstalk factor, two five-wire transmission line structures, namely, parallel symmetric arrangement and bundled random arrangement, are selected for experimental verification. The study shows that the crosstalk factor can accurately express the difference in crosstalk capability between transmission lines at different frequencies. And at the target frequency, the crosstalk suppression effect on the target wire harness can reach more than 90 %, and the bundled random layout transmission line has a higher and more stable crosstalk suppression effect compared with the parallel symmetric layout transmission line.
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (4) , 861-871
Crosstalk Suppression Method at the End of Multiconductor Transmission Lines Based on Crosstalk Factor Theory
Considering the complexity and difficulty of solving the size of crosstalk capability of different transmission lines to each other in the signal transmission process of multi-conductor transmission lines, this paper proposes a new experimental method to determine the crosstalk capability of each transmission line to the other transmission lines on the basis of the theory of multi-conductor transmission lines, and names this crosstalk capability as crosstalk factor as the theoretical support for the selection of the optimal phase combination of excitation source signals of each transmission line to realize a better crosstalk suppression effect on the target transmission line. To realize better crosstalk suppression effect on the target transmission line. Through the comprehensive theoretical analysis of the influence factors of crosstalk factor, two five-wire transmission line structures, namely, parallel symmetric arrangement and bundled random arrangement, are selected for experimental verification. The study shows that the crosstalk factor can accurately express the difference in crosstalk capability between transmission lines at different frequencies. And at the target frequency, the crosstalk suppression effect on the target wire harness can reach more than 90 %, and the bundled random layout transmission line has a higher and more stable crosstalk suppression effect compared with the parallel symmetric layout transmission line.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 3521513
High-Impedance Grounding Fault Detection Method for Distribution Networks Based on a Knowledge Distillation Optimized Lightweight Learning Model
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 3521513
High-Impedance Grounding Fault Detection Method for Distribution Networks Based on a Knowledge Distillation Optimized Lightweight Learning Model
- 6 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Small-Sample GIS Partial Discharge Type Identification Method Based on Fusion of One-Dimensional AT-DRSN and IDRN Models
Different types of partial discharges (PD) in gas insulated switchgear (GIS) cause different degrees of GIS insulation damage, and correct PD identification is critical to GIS insulation status. This paper proposes a multi-model fusion PD pattern recognition method based on one-dimensional adaptive transfer deep residual shrinkage network (AT-DRSN) and improved deep residual network (IDRN), which fully utilizes PD time-domain waveform images generated from field inspection. Firstly, the finite-difference time-domain (FDTD) method and mathematical models are used to simulate GIS partial discharges, and the time-domain waveform image datasets of four typical partial discharge defects are established. Secondly, the network model is built based on time-domain feature sequences and time-order feature parameters respectively, and effectively combined with transfer learning method, and finally, the AT-DRSN and IDRN models are weighted and fused for PD pattern recognition. The results show that the model proposed in this paper can effectively achieve high-precision diagnosis of small-sample GIS PDs, with a recognition accuracy of 98.3%, and the accuracy under strong noise is still greater than 95%, which has higher accuracy and anti-interference performance compared with other methods, and is of reference value for small-sample PD recognition in the field.
- 6 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Small-Sample GIS Partial Discharge Type Identification Method Based on Fusion of One-Dimensional AT-DRSN and IDRN Models
Different types of partial discharges (PD) in gas insulated switchgear (GIS) cause different degrees of GIS insulation damage, and correct PD identification is critical to GIS insulation status. This paper proposes a multi-model fusion PD pattern recognition method based on one-dimensional adaptive transfer deep residual shrinkage network (AT-DRSN) and improved deep residual network (IDRN), which fully utilizes PD time-domain waveform images generated from field inspection. Firstly, the finite-difference time-domain (FDTD) method and mathematical models are used to simulate GIS partial discharges, and the time-domain waveform image datasets of four typical partial discharge defects are established. Secondly, the network model is built based on time-domain feature sequences and time-order feature parameters respectively, and effectively combined with transfer learning method, and finally, the AT-DRSN and IDRN models are weighted and fused for PD pattern recognition. The results show that the model proposed in this paper can effectively achieve high-precision diagnosis of small-sample GIS PDs, with a recognition accuracy of 98.3%, and the accuracy under strong noise is still greater than 95%, which has higher accuracy and anti-interference performance compared with other methods, and is of reference value for small-sample PD recognition in the field.
- 17 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 18267-18278
Partial Discharge Positioning Method in Air-Insulated Substation With Vehicle-Mounted UHF Sensor Array Based on RSSI and Regularization
Monitoring technology for partial discharges (PD) in Air-Insulated Substations (AIS) has undergone development and practical application. Partial discharge positioning based on Received Signal Strength Indication (RSSI) faces a variety of interference factors, including complex environments, multipath effects of signals, expensive fees and huge size of monitoring equipment. These factors jointly lead to the decline of PD positioning accuracy. In order to solve these problems, this paper proposes a substation patrol vehicle positioning technology based on RSSI and vehicle-mounted UHF sensor array. Initially, at a specific distance, multiple measurements, Gaussian filtering, and averaging are performed on a specific PD signal, to determine the RSSI at this distance, and consequently identify the parameters within the Shadowing model. Subsequently, a centralized and balanced preprocessing of the positioning equation is to be performed. Then, derive regularization parameters through the L-curve method and employ the Tikhonov regularization technique to determine the coordinates of the PD source. Simulations and experiments indicate that under simulated disturbances of 0-15% within a space of 30m × 30m × 20m, the proposed method maintains a positioning error within 3.6m. The method is cost-effective and operationally straightforward.
- 17 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 18267-18278
Partial Discharge Positioning Method in Air-Insulated Substation With Vehicle-Mounted UHF Sensor Array Based on RSSI and Regularization
Monitoring technology for partial discharges (PD) in Air-Insulated Substations (AIS) has undergone development and practical application. Partial discharge positioning based on Received Signal Strength Indication (RSSI) faces a variety of interference factors, including complex environments, multipath effects of signals, expensive fees and huge size of monitoring equipment. These factors jointly lead to the decline of PD positioning accuracy. In order to solve these problems, this paper proposes a substation patrol vehicle positioning technology based on RSSI and vehicle-mounted UHF sensor array. Initially, at a specific distance, multiple measurements, Gaussian filtering, and averaging are performed on a specific PD signal, to determine the RSSI at this distance, and consequently identify the parameters within the Shadowing model. Subsequently, a centralized and balanced preprocessing of the positioning equation is to be performed. Then, derive regularization parameters through the L-curve method and employ the Tikhonov regularization technique to determine the coordinates of the PD source. Simulations and experiments indicate that under simulated disturbances of 0-15% within a space of 30m × 30m × 20m, the proposed method maintains a positioning error within 3.6m. The method is cost-effective and operationally straightforward.