Ravi Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ravi Kumar has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Amit Sharma
Government Engineering College Bikaner
2 shared publications - Chandra Shekhar Rajoria
Government Engineering College Bikaner
2 shared publications Amit Sharma
Engineering College Bikaner
1 shared publication- Ayon Chakraborty
Institute of Innovation, Science and Sustainability, Federation University Australia, Ballarat, VIC 3350, Australia
1 shared publication - C. S. Rajoria
Engineering College Bikaner
1 shared publication - Dharmendra Singh
Engineering College Bikaner Department of Mechanical Engineering
1 shared publication
Latest Publications
- Open Access
- 17 September 2026
- Published by Elsevier in SSRN Electronic Journal
Multi-Objective Performance–Emission Optimization of an LPG Dual-Fuel Compression Ignition Engine Using Diesel–Cottonseed Methyl Ester–Diethyl Ether Pilot Blends with Fuzzy Logic and NSGA-II
Liquefied petroleum gas (LPG) can reduce dependence on diesel fuel in compression-ignition engines, but dual-fuel operation may suffer from incomplete combustion and reduced efficiency, particularly at low load. This study experimentally investigates diesel–cottonseed methyl ester (CSOME)–diethyl ether (DEE) pilot blends for LPG-assisted dual-fuel operation of a single-cylinder compression-ignition engine. Two pilot blends, D70B20DEE10 and D55B30DEE15, were tested at 25, 50, 75 and 100% load at a constant speed of 1500 rpm. Brake thermal efficiency (BTE), brake specific energy consumption (BSEC), nitrogen oxides (NOx) and carbon monoxide (CO) were measured and analysed using signal-to-noise ratios, Mamdani fuzzy inference and statistical modelling. The oxygenated pilot blends showed their greatest benefit at higher loads. At full load, D55B30DEE15 increased BTE from 29.584% for neat diesel to 34.06% and reduced BSEC from 12.728 to 10.281 MJ/kWh. CO decreased from 1.07 to 0.78%, while NOx increased from 507.368 to 726.163 ppm. Combustion analysis showed longer ignition delay and stronger premixed heat release with the oxygenated pilot blends at high load, accompanied by higher peak cylinder pressure and shorter combustion duration. The highest experimental Multiple Performance Characteristics Index (MPCI) was 0.7500 for D55B30DEE15 at full load. The additive model predicted 0.7405, corresponding to a deviation of 1.27%. Leave-one-out cross-validation showed that XGBoost performed best for BTE and CO, whereas quadratic regression performed better for BSEC and NOx. NSGA-II further demonstrated the trade-off between efficiency and NOx and identified alternative compromise conditions.
- 17 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMulti-Objective Performance–Emission Optimization of an LPG Dual-Fuel Compression Ignition Engine Using Diesel–Cottonseed Methyl Ester–Diethyl Ether Pilot Blends with Fuzzy Logic and NSGA-II
Liquefied petroleum gas (LPG) can reduce dependence on diesel fuel in compression-ignition engines, but dual-fuel operation may suffer from incomplete combustion and reduced efficiency, particularly at low load. This study experimentally investigates diesel–cottonseed methyl ester (CSOME)–diethyl ether (DEE) pilot blends for LPG-assisted dual-fuel operation of a single-cylinder compression-ignition engine. Two pilot blends, D70B20DEE10 and D55B30DEE15, were tested at 25, 50, 75 and 100% load at a constant speed of 1500 rpm. Brake thermal efficiency (BTE), brake specific energy consumption (BSEC), nitrogen oxides (NOx) and carbon monoxide (CO) were measured and analysed using signal-to-noise ratios, Mamdani fuzzy inference and statistical modelling. The oxygenated pilot blends showed their greatest benefit at higher loads. At full load, D55B30DEE15 increased BTE from 29.584% for neat diesel to 34.06% and reduced BSEC from 12.728 to 10.281 MJ/kWh. CO decreased from 1.07 to 0.78%, while NOx increased from 507.368 to 726.163 ppm. Combustion analysis showed longer ignition delay and stronger premixed heat release with the oxygenated pilot blends at high load, accompanied by higher peak cylinder pressure and shorter combustion duration. The highest experimental Multiple Performance Characteristics Index (MPCI) was 0.7500 for D55B30DEE15 at full load. The additive model predicted 0.7405, corresponding to a deviation of 1.27%. Leave-one-out cross-validation showed that XGBoost performed best for BTE and CO, whereas quadratic regression performed better for BSEC and NOx. NSGA-II further demonstrated the trade-off between efficiency and NOx and identified alternative compromise conditions.
- 2 January 2026
- Published by Springer Nature
- p. 613-636
A Comparative Analysis of PCM and Nanofluids to Enhance the Thermal and Electrical Efficiency of Hybrid PVT Systems
- 2 January 2026
- Published by Springer Nature
- p. 613-636
A Comparative Analysis of PCM and Nanofluids to Enhance the Thermal and Electrical Efficiency of Hybrid PVT Systems
- 2 January 2026
- Published by Springer Nature
- p. 411-438
An Economic Analysis of Hybrid Photovoltaic Thermal (PVT) Systems: A Comprehensive Review
- 2 January 2026
- Published by Springer Nature
- p. 411-438
An Economic Analysis of Hybrid Photovoltaic Thermal (PVT) Systems: A Comprehensive Review
- 11 July 2024
- Published by Springer Nature
- p. 515-525
CO2 Mitigation Potential of Opaque and Semi-transparent Photovoltaic Thermal (PVT) Array with Triangular Duct
- 11 July 2024
- Published by Springer Nature
- p. 515-525
CO2 Mitigation Potential of Opaque and Semi-transparent Photovoltaic Thermal (PVT) Array with Triangular Duct
- 19 April 2024
- Published by Springer Nature
- p. 201-214
Analysis of Thin Layer Mathematical Modelling for Mint Leaves Using Solar Photovoltaic/Thermal (PV/T) System
- 19 April 2024
- Published by Springer Nature
- p. 201-214
Analysis of Thin Layer Mathematical Modelling for Mint Leaves Using Solar Photovoltaic/Thermal (PV/T) System
- Open Access
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Numerical Simulation of Heat Transfer Characteristics for Optimum Air Flow Rate in Triangular PV/T System
The aim of this numerical study is to investigate the heat transfer characteristics of the air flowing in the triangular photovoltaic thermal (PV/T) array/system at variable velocities. The PV/T array in the present analysis is composed of seven photovoltaic (PV) panels connected in series along with a triangular duct throughout its length. The heat transfer analysis in the PV panel (solid component) and visualization of temperature distribution in the PV/T system has been simulated by the use of system coupling of steady state thermal and CFX tools in ANSYS 18.2. Experiment was initially performed at velocity of 1.5 m/s inside the duct by the use of ANSYS software to predict the glass temperature, outlet air temperature, and tedlar temperature of triangular PV/T system. Further, the velocity has been incremented by 1 m/s up to 6.5 m/s to see the overall performance of the system. The validation of simulation results showed a good agreement with the experimental results under reasonable limit. The gain in temperature with the increase in velocity becomes marginal (only 7%) after 4.5 m/s. The temperature contours from the numerical simulation also revealed that cooling up to the last panel is not significant beyond 4.5 m/s. Similar tendency is documented in the overall exergy efficiency which significantly increased to 4.5 m/s and became marginal with further increment in velocity. It can be inferred that the optimum velocity which can fulfill the requirement of cooling of all PV panels along with reasonable thermal output is 4.5 m/s. The thermal energy gain gradually increases as the day progresses and becomes maximum at 2:00 PM. The average thermal energy gain being 9.6% higher than that in the morning (10:00 AM) indicates its suitability for applications requiring moderately high temperature. The present numerical investigation focuses on improving the overall performance of the system without the involvement of any additional cost. The system can be used in various applications like crop drying, space heating, etc. Owing to different outlet air temperatures during the day, the applications can either be utilized independently or can be combined to be used at different times according to the temperature requirement.
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Open AccessNumerical Simulation of Heat Transfer Characteristics for Optimum Air Flow Rate in Triangular PV/T System
The aim of this numerical study is to investigate the heat transfer characteristics of the air flowing in the triangular photovoltaic thermal (PV/T) array/system at variable velocities. The PV/T array in the present analysis is composed of seven photovoltaic (PV) panels connected in series along with a triangular duct throughout its length. The heat transfer analysis in the PV panel (solid component) and visualization of temperature distribution in the PV/T system has been simulated by the use of system coupling of steady state thermal and CFX tools in ANSYS 18.2. Experiment was initially performed at velocity of 1.5 m/s inside the duct by the use of ANSYS software to predict the glass temperature, outlet air temperature, and tedlar temperature of triangular PV/T system. Further, the velocity has been incremented by 1 m/s up to 6.5 m/s to see the overall performance of the system. The validation of simulation results showed a good agreement with the experimental results under reasonable limit. The gain in temperature with the increase in velocity becomes marginal (only 7%) after 4.5 m/s. The temperature contours from the numerical simulation also revealed that cooling up to the last panel is not significant beyond 4.5 m/s. Similar tendency is documented in the overall exergy efficiency which significantly increased to 4.5 m/s and became marginal with further increment in velocity. It can be inferred that the optimum velocity which can fulfill the requirement of cooling of all PV panels along with reasonable thermal output is 4.5 m/s. The thermal energy gain gradually increases as the day progresses and becomes maximum at 2:00 PM. The average thermal energy gain being 9.6% higher than that in the morning (10:00 AM) indicates its suitability for applications requiring moderately high temperature. The present numerical investigation focuses on improving the overall performance of the system without the involvement of any additional cost. The system can be used in various applications like crop drying, space heating, etc. Owing to different outlet air temperatures during the day, the applications can either be utilized independently or can be combined to be used at different times according to the temperature requirement.