Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 20166-20182
Transient Synchronous Stability Assessment and Optimization of Grid-Following and Grid-Forming Converters Paralleled Connected to Grid System
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 20166-20182
Transient Synchronous Stability Assessment and Optimization of Grid-Following and Grid-Forming Converters Paralleled Connected to Grid System
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 9903-9923
Transient Stability Analysis for DC-Link Voltage Synchronization Grid-Forming Converter Considering Frequency-Related Varying Inertia and Internal Voltage
As the penetration of inverter-based resources increases rapidly, the power system's transient stability is facing severe challenges. Grid-forming converters (GFMC) with voltage–frequency support capability are in urgent need of investigation. Conventional power-synchronization-based GFMCs need a constant dc-link voltage (DV), which is not always available. DV synchronization control (DVSC) that can spontaneously maintain constant DV has better adaptability in practice. However, the transient stability of DVSC-based GFMC is relatively complicated and has been rarely studied due to its frequency-related varying inertia and internal voltage. In this article, the kinetic and potential energies of DVSC-based GFMC are analytically deduced, which captures the impact of frequency-related varying inertia and internal voltage. Based on the equal area criterion, the transient stable boundary of DVSC-based GFMC is accurately quantified through an iterative method. Further, the influence of different control parameters on transient stability is revealed. Experimental results verify the effectiveness of the transient stability analysis results.
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 9903-9923
Transient Stability Analysis for DC-Link Voltage Synchronization Grid-Forming Converter Considering Frequency-Related Varying Inertia and Internal Voltage
As the penetration of inverter-based resources increases rapidly, the power system's transient stability is facing severe challenges. Grid-forming converters (GFMC) with voltage–frequency support capability are in urgent need of investigation. Conventional power-synchronization-based GFMCs need a constant dc-link voltage (DV), which is not always available. DV synchronization control (DVSC) that can spontaneously maintain constant DV has better adaptability in practice. However, the transient stability of DVSC-based GFMC is relatively complicated and has been rarely studied due to its frequency-related varying inertia and internal voltage. In this article, the kinetic and potential energies of DVSC-based GFMC are analytically deduced, which captures the impact of frequency-related varying inertia and internal voltage. Based on the equal area criterion, the transient stable boundary of DVSC-based GFMC is accurately quantified through an iterative method. Further, the influence of different control parameters on transient stability is revealed. Experimental results verify the effectiveness of the transient stability analysis results.
- 15 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 16 (4) , 2636-2647
Centralized Control for Paralleled VSCs With Grid-Forming and Oscillation Suppression Capability
Paralleled multiple voltage source converters (VSCs) are adopted in photovoltaic (PV) or energy storage systems, and may suffer from oscillation and fault disturbance issues under various grid conditions. In this paper, a centralized control frame is proposed to suppress the active power oscillation and support the grid voltage/frequency via grid-forming (GFM) control. A virtual synchronous generator (VSG) control is applied as the centralized controller, which communicates with local controllers. The mutual damping and power angle feedback are adopted in the local controller to achieve an accurate active power sharing. The influence of key parameters such as the communication delay and mutual damping are analyzed. Finally, the proposed control is verified though the simulation and hierarchical controller-hardware-in-loop (CHIL) experiments.
- 15 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 16 (4) , 2636-2647
Centralized Control for Paralleled VSCs With Grid-Forming and Oscillation Suppression Capability
Paralleled multiple voltage source converters (VSCs) are adopted in photovoltaic (PV) or energy storage systems, and may suffer from oscillation and fault disturbance issues under various grid conditions. In this paper, a centralized control frame is proposed to suppress the active power oscillation and support the grid voltage/frequency via grid-forming (GFM) control. A virtual synchronous generator (VSG) control is applied as the centralized controller, which communicates with local controllers. The mutual damping and power angle feedback are adopted in the local controller to achieve an accurate active power sharing. The influence of key parameters such as the communication delay and mutual damping are analyzed. Finally, the proposed control is verified though the simulation and hierarchical controller-hardware-in-loop (CHIL) experiments.
- 15 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 13474-13489
Power Reserve Control of PV Grid-Tied Inverter With Transient Stability Constraint
To support the grid frequency, the power reserve control is adopted in the photovoltaic (PV) system without the energy storage. As an important part of the PV system, the influence of the dc-link voltage dynamics is ignored in the grid-tied inverter so that the PV source and grid-tied inverter cooperative control is rarely designed to enhance the transient stability. In this article, the dc-link voltage dynamics are taken into consideration for the transient stability analysis of the grid-following (GFL) control and the grid-forming (GFM) control. It is found that the dc-link voltage dynamics deteriorate the transient stability of the GFL inverter and the GFM inverter. By analogy with the mass-spring-damper system, the enhanced controls are proposed with the equivalent elasticity for the GFL inverter and the GFM inverter. To support the grid frequency and enhance the transient stability, the frequency deviation feedback and equivalent elasticity cooperative control is proposed to regulate the active power of the PV source. Simulation tests are performed on a 10 kW grid-tied PV system and experimental tests are performed on a 1500 W grid-tied PV system, where the effectiveness of enhanced controls is verified.
- 15 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 13474-13489
Power Reserve Control of PV Grid-Tied Inverter With Transient Stability Constraint
To support the grid frequency, the power reserve control is adopted in the photovoltaic (PV) system without the energy storage. As an important part of the PV system, the influence of the dc-link voltage dynamics is ignored in the grid-tied inverter so that the PV source and grid-tied inverter cooperative control is rarely designed to enhance the transient stability. In this article, the dc-link voltage dynamics are taken into consideration for the transient stability analysis of the grid-following (GFL) control and the grid-forming (GFM) control. It is found that the dc-link voltage dynamics deteriorate the transient stability of the GFL inverter and the GFM inverter. By analogy with the mass-spring-damper system, the enhanced controls are proposed with the equivalent elasticity for the GFL inverter and the GFM inverter. To support the grid frequency and enhance the transient stability, the frequency deviation feedback and equivalent elasticity cooperative control is proposed to regulate the active power of the PV source. Simulation tests are performed on a 10 kW grid-tied PV system and experimental tests are performed on a 1500 W grid-tied PV system, where the effectiveness of enhanced controls is verified.
- Open Access
- 27 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (5) , 2582
Characteristics Evaluation and Coordinated Control Strategy of Power-Electronics-Based MMC-HVDC Systems Connected with Wind Farms
Modular multilevel converter–high-voltage direct current (MMC-HVDC) systems are a key technology for integrating large-scale offshore wind farms due to their flexibility, controllability, and decoupled active and reactive power characteristics. However, offshore wind farms rely on power electronic converters, resulting in low inertia, which can worsen frequency fluctuations and affect system stability during major disturbances. Additionally, the decoupled power control of MMC-HVDC systems limits wind farms’ inertia contribution to the AC grid, exacerbating inertia deficiency. To address this, a coordinated inertia support strategy is proposed, utilizing a DC voltage–frequency mapping method that enables wind farms to perceive frequency variations without communication and rapidly provide inertia response. This strategy coordinates wind farms and MMC-HVDC systems to enhance frequency support. Simulations demonstrate that the proposed strategy overcomes MMC-HVDC’s decoupling effect, accelerates frequency recovery, and improves the inertia response speed, achieving faster power support and higher peak power output, thereby enhancing frequency stability. Furthermore, PSCAD/EMTDC simulations were conducted to analyze the transient characteristics of MMC-HVDC under AC-side faults, verifying that braking resistors (BRs) effectively suppress DC overvoltage, reducing wind farm power curtailment and improving system security. This study provides a new approach for frequency stability control in MMC-HVDC-based offshore wind integration and serves as a reference for further optimization of inertia support and fault protection strategies.
- 27 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (5) , 2582
Open AccessCharacteristics Evaluation and Coordinated Control Strategy of Power-Electronics-Based MMC-HVDC Systems Connected with Wind Farms
Modular multilevel converter–high-voltage direct current (MMC-HVDC) systems are a key technology for integrating large-scale offshore wind farms due to their flexibility, controllability, and decoupled active and reactive power characteristics. However, offshore wind farms rely on power electronic converters, resulting in low inertia, which can worsen frequency fluctuations and affect system stability during major disturbances. Additionally, the decoupled power control of MMC-HVDC systems limits wind farms’ inertia contribution to the AC grid, exacerbating inertia deficiency. To address this, a coordinated inertia support strategy is proposed, utilizing a DC voltage–frequency mapping method that enables wind farms to perceive frequency variations without communication and rapidly provide inertia response. This strategy coordinates wind farms and MMC-HVDC systems to enhance frequency support. Simulations demonstrate that the proposed strategy overcomes MMC-HVDC’s decoupling effect, accelerates frequency recovery, and improves the inertia response speed, achieving faster power support and higher peak power output, thereby enhancing frequency stability. Furthermore, PSCAD/EMTDC simulations were conducted to analyze the transient characteristics of MMC-HVDC under AC-side faults, verifying that braking resistors (BRs) effectively suppress DC overvoltage, reducing wind farm power curtailment and improving system security. This study provides a new approach for frequency stability control in MMC-HVDC-based offshore wind integration and serves as a reference for further optimization of inertia support and fault protection strategies.
- 4 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 8990-9003
Transient Stability Evaluation and Decoupled Control for Grid-Following Converters Considering Nonideal Alternating Current Control
In most previous studies about transient synchronization stabilities of grid-following converters (GFLC), alternating current control (ACC) dynamics are often neglected. However, the bandwidth of the ACC cannot be selected too high in some low-switching cases, such as large wind turbines. The adverse effects of ACC must be considered to avoid over-optimistic evaluation of transient stability. There are seldom quantitative and analytic large signal analyses that take the ACC dynamics into account. To fill this gap, an iteration-based accurate transient stability evaluation method is proposed in this article. First, the model of the ACC and line dynamics are deduced. The time-domain analytic solution of current dynamics is obtained. Furthermore, the multivariate implicit function equation set concerning current-frequency-power angle's mapping relation under the critical stable condition is constructed and the transient stability boundary is solved based on the proposed iterative algorithm. The interaction mechanism between the phase-locked-loop (PLL) and ACC is accurately quantified. A simplified transient stability criterion is deduced to preliminarily estimate the adverse effects of ACC on GFLC's transient stability. In addition, a stability-enhanced decoupled PLL strategy is proposed to enable the setting of PLL bandwidth unconstrained by the interaction from ACC, which significantly improves the dynamic response of the GFLC. Simulation and experiments verify the effectiveness and superiority of the proposed stability evaluation method and decoupled PLL strategy.
- 4 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 8990-9003
Transient Stability Evaluation and Decoupled Control for Grid-Following Converters Considering Nonideal Alternating Current Control
In most previous studies about transient synchronization stabilities of grid-following converters (GFLC), alternating current control (ACC) dynamics are often neglected. However, the bandwidth of the ACC cannot be selected too high in some low-switching cases, such as large wind turbines. The adverse effects of ACC must be considered to avoid over-optimistic evaluation of transient stability. There are seldom quantitative and analytic large signal analyses that take the ACC dynamics into account. To fill this gap, an iteration-based accurate transient stability evaluation method is proposed in this article. First, the model of the ACC and line dynamics are deduced. The time-domain analytic solution of current dynamics is obtained. Furthermore, the multivariate implicit function equation set concerning current-frequency-power angle's mapping relation under the critical stable condition is constructed and the transient stability boundary is solved based on the proposed iterative algorithm. The interaction mechanism between the phase-locked-loop (PLL) and ACC is accurately quantified. A simplified transient stability criterion is deduced to preliminarily estimate the adverse effects of ACC on GFLC's transient stability. In addition, a stability-enhanced decoupled PLL strategy is proposed to enable the setting of PLL bandwidth unconstrained by the interaction from ACC, which significantly improves the dynamic response of the GFLC. Simulation and experiments verify the effectiveness and superiority of the proposed stability evaluation method and decoupled PLL strategy.
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 626-636
Power Supporting Control of Grid-Forming Converters Under Grid Voltage Sags for Transient Stability Enhancement and Overcurrent Limitation
There is an increasing demand for grid-forming controlled voltage source converters (GFM-VSC). However, to maintain its voltage source characteristics, the GFM-VSC under grid voltage sags may face the conflicts between transient stability enhancement and overcurrent limitation. In this paper, the power supporting control method is proposed for GFM-VSC to solve this conflict by tuning the active power and voltage magnitude reference. The active power reference is introduced as an extra variable, therefore, the power angle during grid fault and the voltage magnitude can be tuned in the same time to increase the design of freedom. Firstly, the feasible region for power angle and voltage magnitude is shaped considering the constraints in transient stability and current limiting. Under the constraint of feasible region, three optimal control modes are designed to determine the power and voltage reference, concluding the maximum active power, maximum reactive power control and optimal transient control modes. Finally, the performance of the proposed control method is verified by experimental results. Compared with existing fault ride-through methods, the proposed method could achieve higher power supporting capability while maintaining the voltage source characteristics, since which makes full utilization of power angle and voltage boundaries.
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 626-636
Power Supporting Control of Grid-Forming Converters Under Grid Voltage Sags for Transient Stability Enhancement and Overcurrent Limitation
There is an increasing demand for grid-forming controlled voltage source converters (GFM-VSC). However, to maintain its voltage source characteristics, the GFM-VSC under grid voltage sags may face the conflicts between transient stability enhancement and overcurrent limitation. In this paper, the power supporting control method is proposed for GFM-VSC to solve this conflict by tuning the active power and voltage magnitude reference. The active power reference is introduced as an extra variable, therefore, the power angle during grid fault and the voltage magnitude can be tuned in the same time to increase the design of freedom. Firstly, the feasible region for power angle and voltage magnitude is shaped considering the constraints in transient stability and current limiting. Under the constraint of feasible region, three optimal control modes are designed to determine the power and voltage reference, concluding the maximum active power, maximum reactive power control and optimal transient control modes. Finally, the performance of the proposed control method is verified by experimental results. Compared with existing fault ride-through methods, the proposed method could achieve higher power supporting capability while maintaining the voltage source characteristics, since which makes full utilization of power angle and voltage boundaries.
- 17 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 12130-12134
An Online Power Angle Remote Estimation Method for GFL-GFM-Converters Paralleled System
Complicated dynamic interactions in multi-grid-connected converter (GCC) systems have unexpected impacts on the overall response of the system. Online state sharing among different GCCs can enhance the coordination of the whole system. However, due to the significant communication delay, the power angle and frequency states cannot be transmitted rapidly enough. In this letter, an innovative power angle remote estimation method is proposed to realize real-time power angle and frequency information sharing among different GCCs with the local measurement of voltage and power. This method decouples interactive information by revealing the transient response mechanism of the network. The proposed method could inspire distributed cooperative control and online transient stability analysis for multi-GCC systems.
- 17 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 12130-12134
An Online Power Angle Remote Estimation Method for GFL-GFM-Converters Paralleled System
Complicated dynamic interactions in multi-grid-connected converter (GCC) systems have unexpected impacts on the overall response of the system. Online state sharing among different GCCs can enhance the coordination of the whole system. However, due to the significant communication delay, the power angle and frequency states cannot be transmitted rapidly enough. In this letter, an innovative power angle remote estimation method is proposed to realize real-time power angle and frequency information sharing among different GCCs with the local measurement of voltage and power. This method decouples interactive information by revealing the transient response mechanism of the network. The proposed method could inspire distributed cooperative control and online transient stability analysis for multi-GCC systems.
- 19 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (6) , 6974-6988
Transient Stability Analysis for Grid-Tied VSG Considering High-Order Nonlinear Interactions Between Active and Reactive Power Control Loops
Transient stability issues of power converter systems have attracted much attention. Generally, the converter systems behave in high-order nonlinear dynamics due to multiple cascaded control loops, which become obstacles for transient stability analysis. Considering the dynamic coupling between active power and reactive power control loops, the grid-tied virtual synchronous generators (VSG) system is a third-order nonlinear system. Including the equal area criterion (EAC), many conventional methods are only applicable to second-order systems and cannot fully capture damping effects. To fill this gap, a novel iterative EAC method is proposed to handle the transient stability of the third-order VSG system. First, an implicit relationship from the output voltage to the power angle is derived by integral substitution. From energy aspects, the dynamic relations between voltage, power angle, and frequency are approximated by algebraic equations through iterative calculation. The impact of nonlinear damping is also fully captured quantitatively. Both conservatism and quantity of computation are improved compared with previous studies. Furthermore, the critical clearing angles under different disturbance forms and degrees are derived. In addition, some discussions about current limiters’ influence and different controller parameters’ influence are given. Simulation and hardware-in-the-loop experiments based on RT-Lab are conducted to verify the accuracy of the proposed method.
- 19 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (6) , 6974-6988
Transient Stability Analysis for Grid-Tied VSG Considering High-Order Nonlinear Interactions Between Active and Reactive Power Control Loops
Transient stability issues of power converter systems have attracted much attention. Generally, the converter systems behave in high-order nonlinear dynamics due to multiple cascaded control loops, which become obstacles for transient stability analysis. Considering the dynamic coupling between active power and reactive power control loops, the grid-tied virtual synchronous generators (VSG) system is a third-order nonlinear system. Including the equal area criterion (EAC), many conventional methods are only applicable to second-order systems and cannot fully capture damping effects. To fill this gap, a novel iterative EAC method is proposed to handle the transient stability of the third-order VSG system. First, an implicit relationship from the output voltage to the power angle is derived by integral substitution. From energy aspects, the dynamic relations between voltage, power angle, and frequency are approximated by algebraic equations through iterative calculation. The impact of nonlinear damping is also fully captured quantitatively. Both conservatism and quantity of computation are improved compared with previous studies. Furthermore, the critical clearing angles under different disturbance forms and degrees are derived. In addition, some discussions about current limiters’ influence and different controller parameters’ influence are given. Simulation and hardware-in-the-loop experiments based on RT-Lab are conducted to verify the accuracy of the proposed method.