Yuxuan Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuxuan Zhou has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Schmid
Swiss Federal Institute of Technology in Lausanne
1 shared publication - Catherine Dehollain
Swiss Federal Institutes of Technology
1 shared publication - Menghe Jin
Institute of Electrical and Micro Engineering, Swiss Federal Institute of Technology Lausanne (EPFL), Lausanne, Switzerland
1 shared publication - Mingfei Ban
College of Control and Information Engineering, Northeast Forestry University, Harbin 150040, China
1 shared publication - Mohammad Javad Karimi
Institute of Electrical and Micro Engineering, Swiss Federal Institute of Technology Lausanne, Lausanne, Switzerland
1 shared publication - Xianzhen Li
College of Computer and Control Engineering, Northeast Forestry University, Harbin, China
1 shared publication
Latest Publications
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (6) , 7721-7735
Improving Misalignment Tolerance for the Wireless Charging System Using Multiple Coils Coupler
This article proposes a new multiple coils coupler (MCC) comprising a transmitter with numerous circular auxiliary coils connected in series and a lightweight receiver with a circular coil to ensure high antimisalignment ability for the wireless charging system (WCS). First, the proposed MCC's rationality is verified by analyzing the misalignment performance of the asymmetric circular coupler with some auxiliary coils. Furthermore, a comprehensive elucidation is given, outlining the MCC's principle and structure from the magnetic field distribution and mutual inductance model. Second, combining the orthogonal experiments, Ansys Maxwell simulations, and data post-processing method, which feature a low workload and high efficiency, optimize the MCC's parameters. The design flow, misalignment performance, and parameter sensitivity analysis for the MCC are illustrated. Third, a series-series compensated WCS with a maximum system efficiency of 92.2% is constructed to demonstrate the proposed method. The experimental results show that the MCC maintains a relatively stable mutual inductance fluctuation of ±5% within a circular region whose radius is 135 mm (34% of the transmitter width). Besides, the charging current varies less than 5% within this circular region when the load resistance changes from 5 to 25 Ω.
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (6) , 7721-7735
Improving Misalignment Tolerance for the Wireless Charging System Using Multiple Coils Coupler
This article proposes a new multiple coils coupler (MCC) comprising a transmitter with numerous circular auxiliary coils connected in series and a lightweight receiver with a circular coil to ensure high antimisalignment ability for the wireless charging system (WCS). First, the proposed MCC's rationality is verified by analyzing the misalignment performance of the asymmetric circular coupler with some auxiliary coils. Furthermore, a comprehensive elucidation is given, outlining the MCC's principle and structure from the magnetic field distribution and mutual inductance model. Second, combining the orthogonal experiments, Ansys Maxwell simulations, and data post-processing method, which feature a low workload and high efficiency, optimize the MCC's parameters. The design flow, misalignment performance, and parameter sensitivity analysis for the MCC are illustrated. Third, a series-series compensated WCS with a maximum system efficiency of 92.2% is constructed to demonstrate the proposed method. The experimental results show that the MCC maintains a relatively stable mutual inductance fluctuation of ±5% within a circular region whose radius is 135 mm (34% of the transmitter width). Besides, the charging current varies less than 5% within this circular region when the load resistance changes from 5 to 25 Ω.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (3) , 636-647
Wirelessly Powered and Bi-Directional Data Communication System With Adaptive Conversion Chain for Multisite Biomedical Implants Over Single Inductive Link
A wirelessly powered and data communication system is presented which is implemented as a full system, designed for multisite implanted biomedical applications. The system is capable of receiving wireless power and data communication for each implant separately, using inductive links with different resonance frequencies. To achieve this, dual-band coils are presented in the system. In addition, the system provides bi-directional data communication, utilizing amplitude and load shift keying (ASK and LSK) modulation schemes over a single inductive link. The system employs a digitally assisted active rectifier and an automatic resonance tuning system, to improve the power transfer efficiency (PTE) through various coupling coefficients, while minimizing the reverse current and power dissipation. The power control unit enables closed-loop monitoring to prevent high or low power delivery, and it can detect inefficient or excessive wireless power transmission or prevent temperature elevation by limiting the voltage to a safe level. A separated-V b ASK demodulator is presented in the paper which is utilized within the data conversion chain, serving both the external and implanted units. The whole system is fabricated using a standard 180-nm 1.8/3.3 V CMOS process with a core area of 0.82 mm 2 . The system is tested with coupled multisite inductive links and offers the maximum overall PTE of 31.2%, from the Tx coil to the implant load.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (3) , 636-647
Wirelessly Powered and Bi-Directional Data Communication System With Adaptive Conversion Chain for Multisite Biomedical Implants Over Single Inductive Link
A wirelessly powered and data communication system is presented which is implemented as a full system, designed for multisite implanted biomedical applications. The system is capable of receiving wireless power and data communication for each implant separately, using inductive links with different resonance frequencies. To achieve this, dual-band coils are presented in the system. In addition, the system provides bi-directional data communication, utilizing amplitude and load shift keying (ASK and LSK) modulation schemes over a single inductive link. The system employs a digitally assisted active rectifier and an automatic resonance tuning system, to improve the power transfer efficiency (PTE) through various coupling coefficients, while minimizing the reverse current and power dissipation. The power control unit enables closed-loop monitoring to prevent high or low power delivery, and it can detect inefficient or excessive wireless power transmission or prevent temperature elevation by limiting the voltage to a safe level. A separated-V b ASK demodulator is presented in the paper which is utilized within the data conversion chain, serving both the external and implanted units. The whole system is fabricated using a standard 180-nm 1.8/3.3 V CMOS process with a core area of 0.82 mm 2 . The system is tested with coupled multisite inductive links and offers the maximum overall PTE of 31.2%, from the Tx coil to the implant load.