Juarez de Jesus Carmo Junior
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Juarez de Jesus Carmo Junior has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Diogo Cavaco
Department of Cardiology, Hospital de Santa Cruz, Carnaxide, Portugal; Department of Cardiology, Hospital da Luz, Lisboa, Portugal
2 shared publications - Francisco Moscoso Costa
Department of Cardiology, Hospital Santa Cruz , Lisbon
2 shared publications - Gabriel Rodrigues
Kasturba Medical College, Manipal Academy of Higher Education
2 shared publications - Pedro Adragão
Hospital de Santa Cruz, Lisbon, Portugal
2 shared publications - Pedro Carmo
Hospital Santa Cruz , Lisbon , Portugal
2 shared publications - Sara Guerreiro
Cardiology Department, Hospital de Santa Cruz, Unidade Local de Saúde de Lisboa Ocidental , Avenida Prof. Dr. Reinaldo dos Santos, 2790-134 Carnaxide, Lisbon
2 shared publications
Latest Publications
- Open Access
- 15 February 2024
- Published by Revista de Enfermagem, UFPE Online in Revista de Enfermagem UFPE on line
- Vol. 18 (1) , 20
Tecnologias lúdicas na assistência de enfermagem às crianças com câncer: revisão integrativa
Objetivo: identificar, com base em produções científicas, quais as tecnologias lúdicas têm sido incorporadas pelo enfermeiro ao cuidado de crianças durante o tratamento do câncer. Método: revisão integrativa de estudos disponíveis nas bases de dados MEDLINE, SCOPUS, CINAHL, LILACS e bibliotecas virtuais BVS e SCIELO nos últimos dez anos realizada em seis etapas. Resultados: foram identificados 16 estudos agrupados em três categorias temáticas: a tecnologia digital como recurso lúdico na assistência às crianças com câncer; ludicidade por meio de diferentes recursos ante às crianças com câncer; uso do brinquedo terapêutico na assistência às crianças com câncer. Conclusão: diversificadas tecnologias lúdicas para a abordagem das crianças no tratamento do câncer podem ser empregadas na assistência, colaborando para aperfeiçoar a prática da Enfermagem no contexto pediátrico, por meio de uma perspectiva agradável e participativa para as crianças, no que tange aos processos de cuidados, procedimentos e orientações.
- 15 February 2024
- Published by Revista de Enfermagem, UFPE Online in Revista de Enfermagem UFPE on line
- Vol. 18 (1) , 20
Open AccessTecnologias lúdicas na assistência de enfermagem às crianças com câncer: revisão integrativa
Objetivo: identificar, com base em produções científicas, quais as tecnologias lúdicas têm sido incorporadas pelo enfermeiro ao cuidado de crianças durante o tratamento do câncer. Método: revisão integrativa de estudos disponíveis nas bases de dados MEDLINE, SCOPUS, CINAHL, LILACS e bibliotecas virtuais BVS e SCIELO nos últimos dez anos realizada em seis etapas. Resultados: foram identificados 16 estudos agrupados em três categorias temáticas: a tecnologia digital como recurso lúdico na assistência às crianças com câncer; ludicidade por meio de diferentes recursos ante às crianças com câncer; uso do brinquedo terapêutico na assistência às crianças com câncer. Conclusão: diversificadas tecnologias lúdicas para a abordagem das crianças no tratamento do câncer podem ser empregadas na assistência, colaborando para aperfeiçoar a prática da Enfermagem no contexto pediátrico, por meio de uma perspectiva agradável e participativa para as crianças, no que tange aos processos de cuidados, procedimentos e orientações.
- Open Access
- 9 November 2023
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 44 (Supplement)
Leadless vs. transvenous single-chamber pacing - propensity-matched comparison of outcomes
Background: Clinical Trials have demonstrated the safety and efficacy of the leadless pacemaker. However, real-world outcome comparisons between patients receiving conventional VVI and leadless pacemakers are still scarce. The aim of this study was to evaluate short and long-term complications of patients receiving leadless pacemakers in comparison to a population of conventional VVI. Methods: We conducted a single-centre retrospective study of patients receiving the leadless or a conventional VVI between 2014 and 2022. Propensity score matching was performed on 725 patients (156 leadless and 569 conventional) and according to age, sex, coronary artery disease (CAD), chronic kidney disease (CKD), haemodialysis and AF, with a 1:1 matching protocol without replacement (matching tolerance 5%). Complications that occurred up to one month after implantation were considered acute and included access site BARC ≥ 3 bleeding events, pacemaker pocket hematoma requiring medical intervention (either drainage o antibiotic therapy), femoral access infection, pneumothorax, pericardial effusion, cardiac tamponade, and dysfunction of the implanted device. Long-term complications were defined as those occurring at least one month after implantation and included device infection, need for reintervention, and device upgrades due to left ventricular dysfunction. The primary outcome was a composite of acute and long-term complications. Results: A total of 312 patients (80 [73 - 86] years, 63% male, 79% with AF and 7% on dialysis) were included, 156 within each group. The main indication for PM implantation was AF with low ventricular rate (48%), followed by atrioventricular block (31%) and sick sinus syndrome (13%). In total, 19 patients (16%) had a previously implanted device, and 14 (4%) had previously been submitted to lead extraction, of which 10 (71%) were due to device-related infection. All of these were more frequent in patients receiving the leadless pacemaker (p = 0.001). During a median follow-up of 26 [11 - 47] months, a total of 32 patients (10%) had a complication related to the implantation of the device – table 1. While intra-hospital complications showed only a tendency towards higher incidence in the VVI group (5% vs 3%; p = 0.124), overall complications (16% vs 5%) and long-term complications (12% vs 2%) were higher in the VVI group (p < 0.001 for both). The Kaplan-Meier curves for the primary outcome showed a significantly lower event-rate for patients receiving the leadless pacemaker – Figure 1. Conclusions: In this propensity-matched study, leadless pacemaker implantation was associated with a lower incidence of complications during follow-up, in comparison to conventional VVI pacemaker.
- 9 November 2023
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 44 (Supplement)
Open AccessLeadless vs. transvenous single-chamber pacing - propensity-matched comparison of outcomes
Background: Clinical Trials have demonstrated the safety and efficacy of the leadless pacemaker. However, real-world outcome comparisons between patients receiving conventional VVI and leadless pacemakers are still scarce. The aim of this study was to evaluate short and long-term complications of patients receiving leadless pacemakers in comparison to a population of conventional VVI. Methods: We conducted a single-centre retrospective study of patients receiving the leadless or a conventional VVI between 2014 and 2022. Propensity score matching was performed on 725 patients (156 leadless and 569 conventional) and according to age, sex, coronary artery disease (CAD), chronic kidney disease (CKD), haemodialysis and AF, with a 1:1 matching protocol without replacement (matching tolerance 5%). Complications that occurred up to one month after implantation were considered acute and included access site BARC ≥ 3 bleeding events, pacemaker pocket hematoma requiring medical intervention (either drainage o antibiotic therapy), femoral access infection, pneumothorax, pericardial effusion, cardiac tamponade, and dysfunction of the implanted device. Long-term complications were defined as those occurring at least one month after implantation and included device infection, need for reintervention, and device upgrades due to left ventricular dysfunction. The primary outcome was a composite of acute and long-term complications. Results: A total of 312 patients (80 [73 - 86] years, 63% male, 79% with AF and 7% on dialysis) were included, 156 within each group. The main indication for PM implantation was AF with low ventricular rate (48%), followed by atrioventricular block (31%) and sick sinus syndrome (13%). In total, 19 patients (16%) had a previously implanted device, and 14 (4%) had previously been submitted to lead extraction, of which 10 (71%) were due to device-related infection. All of these were more frequent in patients receiving the leadless pacemaker (p = 0.001). During a median follow-up of 26 [11 - 47] months, a total of 32 patients (10%) had a complication related to the implantation of the device – table 1. While intra-hospital complications showed only a tendency towards higher incidence in the VVI group (5% vs 3%; p = 0.124), overall complications (16% vs 5%) and long-term complications (12% vs 2%) were higher in the VVI group (p < 0.001 for both). The Kaplan-Meier curves for the primary outcome showed a significantly lower event-rate for patients receiving the leadless pacemaker – Figure 1. Conclusions: In this propensity-matched study, leadless pacemaker implantation was associated with a lower incidence of complications during follow-up, in comparison to conventional VVI pacemaker.
- Open Access
- 24 May 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (Supplement)
Association between left ventricular wall-thickness by CT and endocardial voltage potentials in patients with ischemic cardiomyopathy
Funding Acknowledgements: Type of funding sources: None. Background: Although cardiac magnetic resonance (CMR) is the gold standard for planning ventricular tachycardia (VT) ablation, its accuracy is hindered in patients with implanted cardiac defibrillators (ICD) and resynchronization therapy (CRT). Cardiac computed tomography (CT) has emerged as an alternative for ablation planning in these patients. This pilot study aimed to evaluate the relationship between wall thickness (WT) on CT and voltage of electrical potentials on endocardial electroanatomic mapping (EAM) in patients with ischemic cardiomyopathy. Methods: Single centre retrospective study enrolling consecutive patients with ischemic cardiomyopathy referred for endocardial VT ablation that underwent cardiac CT for procedure planning since 2021. Patients were excluded if EAM had < 1000 data points. ADAS 3D® software was used to analyse CT images, automatically segmenting the left ventricle (LV) into the 17 American Heart Association segments and calculating end-diastolic WT for each one. Four standardized views (anterior-posterior, posterior-anterior, superior, and inferior) of the segmented LV on ADAS 3D® were used to aid in manual segmentation of the EAM. The endocardial voltage maps were created using CARTO3® software (Figure 1). For each patient, EAM was interpreted to create 2 different bulls’ eye maps, according to the presence or absence of bipolar potentials < 0.5 (dense scar) or < 1.5mV (low voltage). Only segments with >20% extension of low bipolar voltage were considered as altered. Results: We included a cohort of 8 patients (mean age 67±12 years, 87.5% male, median LVEF of 32% [IQR 25-49]). All but one patient had implanted cardiac device (6 ICD, 1 CRT-D). Cardiac CT was performed 1 day (IQR 0-2) before the ablation. Overall, 136 segments were analysed, 8 of which did not have voltage information. Of the remaining 128, 51 (39.8%) had dense scar and 57 (41.9%) had low voltage. There was a good correlation between mean WT and the presence or absence of both dense scar (area under de curve (AUC) 0.799, p<0.001) and low voltage (AUC 0.838, p<0.001) in each LV segment. Conclusion: WT measured by CT appears to have a strong correlation with dense scar and low voltage in EAM in patients with ischemic cardiomyopathy undergoing VT ablation. This technique may be useful to plan interventions in patients in whom CMR is not feasible.
- 24 May 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (Supplement)
Open AccessAssociation between left ventricular wall-thickness by CT and endocardial voltage potentials in patients with ischemic cardiomyopathy
Funding Acknowledgements: Type of funding sources: None. Background: Although cardiac magnetic resonance (CMR) is the gold standard for planning ventricular tachycardia (VT) ablation, its accuracy is hindered in patients with implanted cardiac defibrillators (ICD) and resynchronization therapy (CRT). Cardiac computed tomography (CT) has emerged as an alternative for ablation planning in these patients. This pilot study aimed to evaluate the relationship between wall thickness (WT) on CT and voltage of electrical potentials on endocardial electroanatomic mapping (EAM) in patients with ischemic cardiomyopathy. Methods: Single centre retrospective study enrolling consecutive patients with ischemic cardiomyopathy referred for endocardial VT ablation that underwent cardiac CT for procedure planning since 2021. Patients were excluded if EAM had < 1000 data points. ADAS 3D® software was used to analyse CT images, automatically segmenting the left ventricle (LV) into the 17 American Heart Association segments and calculating end-diastolic WT for each one. Four standardized views (anterior-posterior, posterior-anterior, superior, and inferior) of the segmented LV on ADAS 3D® were used to aid in manual segmentation of the EAM. The endocardial voltage maps were created using CARTO3® software (Figure 1). For each patient, EAM was interpreted to create 2 different bulls’ eye maps, according to the presence or absence of bipolar potentials < 0.5 (dense scar) or < 1.5mV (low voltage). Only segments with >20% extension of low bipolar voltage were considered as altered. Results: We included a cohort of 8 patients (mean age 67±12 years, 87.5% male, median LVEF of 32% [IQR 25-49]). All but one patient had implanted cardiac device (6 ICD, 1 CRT-D). Cardiac CT was performed 1 day (IQR 0-2) before the ablation. Overall, 136 segments were analysed, 8 of which did not have voltage information. Of the remaining 128, 51 (39.8%) had dense scar and 57 (41.9%) had low voltage. There was a good correlation between mean WT and the presence or absence of both dense scar (area under de curve (AUC) 0.799, p<0.001) and low voltage (AUC 0.838, p<0.001) in each LV segment. Conclusion: WT measured by CT appears to have a strong correlation with dense scar and low voltage in EAM in patients with ischemic cardiomyopathy undergoing VT ablation. This technique may be useful to plan interventions in patients in whom CMR is not feasible.
- Open Access
- 1 August 2017
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 38 (suppl_1)
4113Long-term evaluation of the Ross procedure: clinical and echocardiographic follow-up at 20 years
Background: Ross surgery is a technically complex procedure used in children and young adults requiring replacement of the aortic valve (AV), in which the native pulmonary valve is switched to the aortic position - autograft (Ag) - and a cryopreserved homograft (Hg) is implanted in a pulmonary position.
- 1 August 2017
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 38 (suppl_1)
Open Access4113Long-term evaluation of the Ross procedure: clinical and echocardiographic follow-up at 20 years
Background: Ross surgery is a technically complex procedure used in children and young adults requiring replacement of the aortic valve (AV), in which the native pulmonary valve is switched to the aortic position - autograft (Ag) - and a cryopreserved homograft (Hg) is implanted in a pulmonary position.