Charles J. Stark
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Charles J. Stark has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Catherine A. Wu
Department of Cardiothoracic Surgery, Stanford University School of Medicine, Falk Cardiovascular Research Center, 300 Pasteur Drive, Stanford, CA 94305, USA
2 shared publications - Yiping Joseph Woo
Department of Cardiothoracic Surgery, Stanford University School of Medicine, Palo Alto, CA, USA
2 shared publications - Akshay Venkatesh
Department of Medicine, School of Medicine, University of Washington, Seattle, WA 98105, USA
1 shared publication Andrei Alexandru Mircea
Department of Biomedical Engineering Northwestern University Evanston IL USA
1 shared publicationBasil M. Baccouche
Department of Cardiothoracic Surgery (Y.Z., S.Y., M.H.P., A.V., C.J.S., N.A.T., S.K.W., S. Ethiraj, R.J.W., L.E.L., S.H.L., D.M.M., C.A.W., S.H., B.P., D.R., H.B., M.A.W., B.M.B., P.K.P., S. Elde, H.W., Y.J.W.), Stanford University, CA
1 shared publicationBipul Pokhrel
Department of Cardiothoracic Surgery (Y.Z., S.Y., M.H.P., A.V., C.J.S., N.A.T., S.K.W., S. Ethiraj, R.J.W., L.E.L., S.H.L., D.M.M., C.A.W., S.H., B.P., D.R., H.B., M.A.W., B.M.B., P.K.P., S. Elde, H.W., Y.J.W.), Stanford University, CA
1 shared publication
Latest Publications
- 27 November 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 14 (1) , 211-218
Glycidyl methacrylate and methacrylic anhydride characterization for silk fibroin methacrylation in tissue engineering
The field of tissue engineering has been an ever-evolving discipline with a principal direction of creating artificial constructs to improve biological tissue types.
- 27 November 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 14 (1) , 211-218
Glycidyl methacrylate and methacrylic anhydride characterization for silk fibroin methacrylation in tissue engineering
The field of tissue engineering has been an ever-evolving discipline with a principal direction of creating artificial constructs to improve biological tissue types.
- Open Access
- 22 July 2025
- Published by Wiley in The Journal of Physiology
- Vol. 604 (13) , 5139-5158
Advances in cardiac devices and bioelectronics augmented with artificial intelligence
Diagnostic bioelectronics such as the electrocardiogram have become increasingly prevalent in the management of cardiovascular diseases like atrial fibrillation. While these devices provide meaningful clinical value, their complex and profuse data output requires considerable labour and training from clinicians to diagnose disease. This abundant production of complex data has made diagnostic bioelectronics a prime target for artificial intelligence (AI) integration. AI‐integrated diagnostic bioelectronics have already left the clinic as widely prevalent wearable smartwatches equipped with single‐lead electrocardiography sensors. Meanwhile, substantial innovation is also taking place at the intersection of other sensing modalities in the form of edge computing. Here, we overview the implementation and embedding of AI into diagnostic bioelectronics of multiple sensing modalities, including electrocardiography, photoplethysmography, echocardiography, and others, and discuss the recent advances made by medical device companies and researchers alike at the interface between the heart and AI. image
- 22 July 2025
- Published by Wiley in The Journal of Physiology
- Vol. 604 (13) , 5139-5158
Open AccessAdvances in cardiac devices and bioelectronics augmented with artificial intelligence
Diagnostic bioelectronics such as the electrocardiogram have become increasingly prevalent in the management of cardiovascular diseases like atrial fibrillation. While these devices provide meaningful clinical value, their complex and profuse data output requires considerable labour and training from clinicians to diagnose disease. This abundant production of complex data has made diagnostic bioelectronics a prime target for artificial intelligence (AI) integration. AI‐integrated diagnostic bioelectronics have already left the clinic as widely prevalent wearable smartwatches equipped with single‐lead electrocardiography sensors. Meanwhile, substantial innovation is also taking place at the intersection of other sensing modalities in the form of edge computing. Here, we overview the implementation and embedding of AI into diagnostic bioelectronics of multiple sensing modalities, including electrocardiography, photoplethysmography, echocardiography, and others, and discuss the recent advances made by medical device companies and researchers alike at the interface between the heart and AI. image
- 1 April 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 17 (4) , e013196
Large Animal Translational Validation of 3 Mitral Valve Repair Operations for Mitral Regurgitation Using a Mitral Valve Prolapse Model: A Comprehensive In Vivo Biomechanical Engineering Analysis
BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P =0.02) and remodeling techniques (0.30±0.15 N; P =0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P =0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P =0.02) and triangular resectional techniques (0.36±0.27 N; P =0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P =0.02) or 6 neochordae (0.19±0.16 N; P =0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae ( P =0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P =0.01) and 2 neochordae (0.29±0.18 N; P =0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.
- 1 April 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 17 (4) , e013196
Large Animal Translational Validation of 3 Mitral Valve Repair Operations for Mitral Regurgitation Using a Mitral Valve Prolapse Model: A Comprehensive In Vivo Biomechanical Engineering Analysis
BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P =0.02) and remodeling techniques (0.30±0.15 N; P =0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P =0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P =0.02) and triangular resectional techniques (0.36±0.27 N; P =0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P =0.02) or 6 neochordae (0.19±0.16 N; P =0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae ( P =0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P =0.01) and 2 neochordae (0.29±0.18 N; P =0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.