*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yueqi Qiu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Diffusion Weighted Fast Spin Echo With RF ‐Encoded Slabs for Portable Low‐Field MRI Systems

    by Philip K. Lee, Yueqi Qiu, Suen Chen, Changyue Wang, Zhiyong Zhang

    Purpose: To develop a robust diffusion weighted (DW) acquisition with clinically feasible scan times for portable MRI systems. Methods: A linear reconstruction model including: tailored RF‐encoding schemes, motion‐induced phases, and systematic phase errors was developed for slab diffusion weighted fast spin echo (FSE) data acquired with quadratic phase increment. Systematic phases imparted by diffusion gradients were obtained using a calibration phantom. Trace‐weighted DW‐FSE was compared to DW‐EPI in vivo on a portable 110 mT H‐based system. A high‐NEX DW‐FSE acquisition was performed in healthy volunteers followed by Monte Carlo retrospective undersampling to evaluate expected image quality and mean diffusivity variation in a DWI protocol with clinically feasible scan times. Results: CPMG calibration and polynomials fitted to systematic phase errors enabled accurate estimation of motion‐induced phases. Accounting of different phase sources reduced ghosting artifacts and improved SNR efficiency by enabling RF‐encoding. RF‐encoded slab DW‐FSE obtained in vivo trace‐weighted images without distortion artifacts and with voxel sizes 5× smaller than DW‐EPI. The retrospectively undersampled acquisition showed that 12 cm slice coverage with voxel size 2.5 × 2.5 × 5 mm 3 could be achieved in 12 min scan time. The mean diffusivity standard deviation between Monte Carlo trials was 0.2 × 10 −3 mm 2 /s. Conclusion: Diffusion weighted FSE is a robust, distortionless approach for high SNR efficiency DWI on portable MRI systems. Multiband quadratic phase increment DW‐FSE leverages the low SAR and higher peak B 1 provided by low field strengths and is less dependent on performant hardware compared to DW‐EPI.

  • A Fast and Reliable Eddy Current Measurement Method in Portable Low-Field MRI

    by Suen Chen, Yueqi Qiu, Sijie Zhong, Philip Kenneth Lee, Hao Chen, Zhiyong Zhang

    Portable permanent low-field magnetic resonance imaging (MRI) is gaining increasing attention due to its low cost, safer scanning, and broad range of applications, such as emergency. However, frequent relocation of portable systems may alter their eddy current performances, which can degrade image quality unless timely recalibration is performed. Conventional eddy current measurement method relies on image-phase analysis and typically require several hours in low-field MRI due to low signal-to-noise ratios (SNR). In this work, a fast eddy current measurement method using field probes, which consists of an array of six 1H probes, is presented. The acquisition time was reduced by a factor of 100, from 9 hours to 5 minutes, while successfully reducing residual eddy currents to within ± 0.03% of the applied gradient amplitude over whole measurement. To overcome the poor SNR, the probe size was increased by leveraging the reduced susceptibility effects in low-field. Measurement sequences were optimized to address challenges such as field inhomogeneity and residual magnetism effects in low-field. Gradient pre-emphasis parameters were adjusted according to the derived eddy current parameters. To evaluate correction efficiency, phantom and volunteer experiments were conducted by acquiring eddy current maps, fast spin-echo, and diffusion-weighted echo-planar imaging images. It was found that corrections obtained using the field probe method outperformed those obtained by image-phase based method within the same measurement iterations, providing more stable reduction of eddy-current-induced artifacts. These results demonstrate the potential of the proposed method as a reliable timely solution for eddy currents correction in portable permanent low-field MRI.


  • High‐Accelerated Parallel Imaging With the Inherent Local Feature in PE ‐ xSPEN MRI

    by Ke Dai, Eddy Solomon, Philip K. Lee, Guangyu Tao, Yueqi Qiu, Hao Chen, Lucio Frydman, Zhiyong Zhang

    Purpose: To achieve highly accelerated high‐resolution imaging with PE‐xSPEN that efficiently utilizes the spatiotemporal encoded signals to physically distinguish contributions from distinct spatial locations prior to k‐space acquisition, enabling the differentiation of aliased localized information in k‐space. Methods: In the conventional k‐space, undersampling along the phase‐encoding dimension results in aliasing and overlapping replicas of the object along the spatial direction. The modulated hyperbolic phase arising from the PE‐xSPEN encoding induces coupling between the and dimensions. So that for a given k‐space location, the signal is predominantly contributed by local voxels. While undersampling along the PE dimension still causes aliased spatial replicas, these replicas remain distinguishable even without multi‐channel coils after applying the traditional inverse Fourier transform along the undersampled dimension. Combining with parallel imaging, this approach enhances unfolding efficiency compared to traditional Fourier‐encoded signals. Results: Combining with GRAPPA, the undersampled signals along the dimension can be reconstructed with fewer residual aliasing in PE‐xSPEN compared to the traditional Fourier‐encoded signals. The performance gain is demonstrated by MRI simulation, phantom tests, and in vivo brain experiments on 3T scanner. Conclusion: The proposed PE‐xSPEN GRAPPA framework utilizes hyperbolic phase modulation to control aliasing artifacts and generate ‐dependent coil response, reducing artifacts and noise amplification.

  • Multiband Fast Spin Echo on portable low‐field systems

    by Philip K. Lee, Yueqi Qiu, Changyue Wang, Zhiyong Zhang

    Purpose: To improve the SNR efficiency of Fast Spin Echo (FSE) using RF‐encoded multiband imaging and to develop techniques that correct artifacts from non‐Carr–Purcell–Meiboom–Gill (CPMG) magnetization arising from system imperfections. Methods: Optimal refocusing pulse band phase modulations that satisfy the CPMG condition were calculated for different multiband factors. Fast recovery was used to enhance T2 contrast. Quadratic phase refocusing pulses, phase encode and slice select gradient reshaping, and zeroth‐order phase calibrations were tested to reduce residual non‐CPMG magnetization. Image contrast of T2‐weighted and T1‐weighted imaging and SNR improvements were evaluated in phantom and in vivo experiments on an in‐house portable 110 mT system. Results: The peak of multiband refocusing pulses using the obtained optimal phase modulations varies closely with the expected increase of . Modulations satisfying the CPMG phase condition provide similar peak reductions to previously proposed subband modulation schemes. Quadratic phase increment reduced shading from residual non‐CPMG magnetization, and bipolar phase encoding reduced residual ghosting. Zeroth‐order RF phase calibrations on the excitation and tipup, and slice select reshaping that minimized residual phase on 2D maps calculated from even and odd echo images improved contrast with long T2 species. RF‐encoded multiband FSE improved SNR by a factor close to the theoretical expected improvement of . Conclusion: RF‐encoded multiband imaging is a viable approach for improving SNR efficiency on low‐field portable systems.


  • Toward Contact-Free Motion Sensing Technique in Low-Field MRI Using Beat Pilot Tone

    by Suen Chen, Haoyu Sun, Suma Anand, Michael Lustig, Yueqi Qiu, Sijie Zhong, Hao Chen, Zhiyong Zhang

    Low-field magnetic resonance imaging (MRI) suffers from fundamentally low signal-to-noise ratio (SNR), which is typically mitigated by acquiring multiple sets of imaging data and averaging them. However, this approach lengthens the scan time and can make images highly susceptible to motion artifacts. In this article, a novel contact-free radio frequency (RF) motion sensor beat pilot tone (BPT), which has high temporal resolution and is easy to be integrated into both MR system and imaging workflow, was first introduced in a 0.25 T permanent C-shaped MRI system. We improved the portability of BPT by integrating it into a 10 cm × 5 cm × 2 cm device and retained its adjustability in power and frequency. We compared BPT with another contact-free motion sensing technology, pilot tone (PT), for detecting the same motion. The results indicate that the motion modulation achieved by BPT is over six times that of PT, demonstrating that BPT has higher detection sensitivity. A phantom experiment was performed to suggest BPT has no adverse impact on imaging. We conducted series of in vivo experiments and demonstrated that BPT has the ability to detect different motion patterns, such as shaking and nodding head motion, respiratory motion, and cardiac motion. With BPT signal guidance, we successfully reconstructed motion-resolved images of a head scan under in-plane motion and abdominal imaging under free-breathing. SNR of images is higher than previous low-field images, and the motion artifacts are reduced, which shows the potential for wide application of BPT in low-field MRI.


  • Spatiotemporal encoding MRI in a portable low‐field system

    by Yueqi Qiu, Ke Dai, Sijie Zhong, Suen Chen, Changyue Wang, Hao Chen, Lucio Frydman, Zhiyong Zhang

    Purpose: Demonstrate the potential of spatiotemporal encoding (SPEN) MRI to deliver largely undistorted 2D, 3D, and diffusion weighted images on a 110 mT portable system.Methods: SPEN's quadratic phase modulation was used to subsample the low‐bandwidth dimension of echo planar acquisitions, delivering alias‐free images with an enhanced immunity to image distortions in a laboratory‐built, low‐field, portable MRI system lacking multiple receivers.Results: Healthy brain images with different SPEN time‐bandwidth products and subsampling factors were collected. These compared favorably to EPI acquisitions including topup corrections. Robust 3D and diffusion weighted SPEN images of diagnostic value were demonstrated, with 2.5 mm isotropic resolutions achieved in 3 min scans. This performance took advantage of the low specific absorption rate and relative long TEs associated with low‐field MRI.Conclusion: SPEN MRI provides a robust and advantageous fast acquisition approach to obtain faithful 3D images and DWI data in low‐cost, portable, low‐field systems without parallel acceleration.