SKSireetorn Kuharat

Sireetorn Kuharat

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sireetorn Kuharat has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • FINITE ELEMENT STRESS ANALYSIS OF A BUMBLEBEE-INSPIRED MICRO AIR VEHICLE (MAV) WING

    by James Buxton, O. Anwar Bég, Tasveer A. Bég, M. M. Bhatti, S. Kuharat, Ali Kadir, Walid S. Jouri

    A computational study is described of the structural performance of a bumblebee-inspired wing for a Micro Aerial Vehicle (MAV) during the initial downstroke phase of take-off using Finite Element Analysis (FEA). A detailed three-dimensional model of the forewing and hindwing was developed to replicate the morphological and structural features of the insect wing. Static FEA was performed within the ANSYS Workbench to assess stress distribution, strain, and deformation under aerodynamic loading conditions experienced during the first wing stroke, based on a wingspan of 18[ ]mm and the species-specific flapping frequency of 130[ ]Hz. The results indicate that the natural venation pattern of the wing provides effective load distribution, reducing stress concentrations along the wingspan. Peak Von Mises stresses were localized along the leading edge, following the primary branch of the vein structure, while maximum deformation occurred at the wingtip, consistent with experimentally observed honeybee wing deformation. The static pressure case simulations reveal that maximum deformation (total displacement) is observed to consistently decrease with increasing Young’s Modulus. At 2[ ]GPa, the wing exhibits the highest displacement of 1189[ ] [ ]m, and this is strongly reduced to 793[ ] [ ]m at 3[ ]GPa, 595[ ] [ ]m at 4[ ]GPa, and 476[ ] [ ]m at 5[ ]GPa. The Von Mises elastic strain varied significantly with stiffness. The strain decreases when Young’s modulus increases for chitin, with values of [ ] at 2[ ]GPa, [ ] at 3[ ]GPa, [ ] at 4[ ]GPa, and [ ] at 5[ ]GPa. Notably, the Von Mises stress results remained nearly constant across all Young’s Modulus values, hovering around 4.93[ ]MPa. For the acceleration case, at 2[ ]GPa, the maximum total deformation was recorded as 1094[ ] [ ]m. When the modulus was increased to 3[ ]GPa, the displacement reduced to 723[ ] [ ]m, followed by 547[ ] [ ]m at 4[ ]GPa and 438[ ] [ ]m at 5[ ]GPa. As with the static simulation, in all cases, the displacement was concentrated toward the wing tip, with the largest deformation occurring along the outer regions of the bumblebee wing structure, away from the fixed support. Furthermore, the Von Mises strain recorded when the Young’s Modulus was set to 4[ ]GPa exceeds that computed in the other three cases (5, 3, and 2[ ]GPa). As with the static pressure simulations, the Von Mises stress sustains a consistent value across all the Young’s Modulus values, maintaining a peak value of approximately 4.27[ ]MPa. Peak Von Mises stress is observed at the leading edge, where the leading vein changes direction to follow the wing contours, which are most susceptible to loading and are subjected to the highest forces resulting from flight. The findings also demonstrate the potential of biomimetic venation layouts to enhance the strength-to-weight ratio in small-scale UAV wings, thereby supporting efficient lift production with minimal weight penalties.

  • CFD simulation of the Impact of Eagle Bioinspired Wing Slots for Reducing Induced Drag and Enhancing Flight Efficiency in UAVs

    by Issa Momodu, Anwar Beg, Sireetorn Kuharat

    This research examines the aerodynamic performance of three UAV wing configurations base wing, Model A with cambered wingslots, and Model B with symmetrical wingslots at low Reynolds numbers. Using CFD simulations in ANSYS FLUENT, key parameters such as lift coefficient, drag coefficient, induced drag, and lift-to-drag ratio were analysed across angles of attack from 0° to 15° and flight velocities of 8 m/s, 10 m/s, and 12 m/s. Results reveal that wing slots enhance aerodynamic efficiency by 12.5% at low angles of attack. Model A with cambered wingslots excels in pre-stall lift generation, while Model B with symmetrical wingslots achieves lower drag at lower angles. Both configu-rations significantly reduce induced drag by up to 29% during cruise conditions, highlighting their effectiveness in im-proving UAV performance.

  • Electro-osmotically modulated viscoelastic SWCNT-blood flow in symmetric/nonsymmetric stenosed arteries with heat generation using a fractional second grade model

    by Mahadev M. Channakote, O. Anwar Bég, S. Kuharat, M. Shekar, C. Siddabasappa

    This study examines the electro-osmotically modulated viscoelastic blood flow in arteries with both symmetric and nonsymmetric stenosis, accounting for heat generation and thermal buoyancy effects. Blood is modeled as a fractional second-grade fluid to more accurately capture its viscoelastic and memory-dependent behavior. The Debye–Hückel linearization is applied to analyze the electro-osmotic effects. The governing partial differential equations are reduced to a system of ordinary differential equations using appropriate scaling transformations. Analytical solutions are derived for the resulting nondimensional boundary value problem. Key flow characteristics, such as axial velocity, temperature distribution, electric potential, volumetric flow rate, and wall shear stress, are computed and illustrated graphically using the Mathematica software. The computations reveal that axial velocity decreases near the arterial walls but increases in the core region for both symmetric [ ] and nonsymmetric [ ] stenoses with rising Helmholtz–Smoluchowski velocity [ ], CNT volume fraction [ ], Debye length parameter [ ], and stenosis height [ ] Heat generation [ ] further enhances both velocity and temperature. Increasing [ ] reduces temperature and wall shear stress [ ], while higher flow rate [ ] and stenosis height [ ] are elevated [ ]. Nonsymmetric stenoses yield higher temperatures than symmetric ones. Trapping boluses grow in size and number with increasing [ ] for both stenosis types. These findings underscore the significant role of electro-osmotic and viscoelastic effects in hemodynamic regulation, with potential biomedical applications.

  • Thermomagnetic Bioconvection Flow in a Semitrapezoidal Enclosure Filled With a Porous Medium Containing Oxytactic Micro-Organisms: Modeling Hybrid Magnetic Biofuel Cells

    by K. Venkatadri, P. Rajarajeswari, O. Anwar Bég, V. Ramachandra Prasad, H. J. Leonard, S. Kuharat, Raja Rajeswari

    Hybrid fuel cells are becoming increasingly popular in 21st century energy systems engineering. These systems combine multiple features including various geometries, electromagnetic fluids, bacteria (micro-organisms), thermosolutal convection, and porous media. Motivated by these developments in the present work, we simulate the two-dimensional magnetohydrodynamic (MHD) natural triple convection flow in a semitrapezoidal enclosure saturated with electrically conducting water containing oxytactic micro-organisms and oxygen species. The Darcy–Brinkman model is deployed for porous media drag effects. The primitive governing partial differential conservation equations for mass, momentum, energy, oxygen species, and motile micro-organism species density are transformed using a vorticity–stream function formulation and nondimensional variables into a nonlinear boundary value problem. A numerical solution is obtained using a finite difference method with incremental time steps. The mathematical model features a number of controlling parameters, i.e., Prandtl number, Rayleigh number, bioconvective Rayleigh number, Darcy parameter, Hartmann (magnetic body force) number, Lewis number, Péclet number, oxygen diffusion ratio, and fraction of consumption oxygen to diffusion of oxygen parameter. Transport characteristics (streamlines, isotherms, oxygen isoconcentration, and motile micro-organism concentration) are computed for several of these parameters. Micro-organisms’ impact on the rate of heat transfer at the boundaries is found to be beneficial or destructive, depending on combination of other parameters in the simulations. Additionally, Nusselt number and oxygen species Sherwood number are computed at the hot vertical wall. The simulations are relevant to hybrid electromagnetic microbial fuel cells.


  • Open Access

    Computational hemodynamic simulation of non-Newtonian fluid-structure interaction in a curved stenotic artery

    by Sireetorn Kuharat, M. A. Chaudhry, O. Anwar Beg, Tasveer A. Bég

    This paper focuses on deploying Computational Fluid Dynamics (CFD) and Fluid-Structure Interaction (FSI) to investigate key characteristics associated with Cardiovascular Diseases (CVDs), a leading cause of global mortality. CVDs encompass various heart and blood vessel disorders, including coronary artery disease, stroke and atherosclerosis, which significantly impact arteries. Risk factors such as high blood pressure and obesity contribute to atherosclerosis, which is characterized by narrowed arteries due to fatty deposits, impeding blood flow and increasing heart attack and stroke risks. To simulate blood flow behaviour and its effects on artery stenosis formation, ANSYS-based CFD and monolithic (one-way) Fluid-Structure Interaction (FSI) analyses are deployed in this work. Extensive visualization of blood flow patterns relevant to patient-specific conditions is included using the non-Newtonian (Carreau shear-thinning) bio-rheological model. These simulations start with creating a three-dimensional patient artery model, followed by applying CFD/FSI methodologies to solve the equations iteratively with realistic boundary conditions. Velocity, pressure, wall shear stress (WSS), Von mises stress and strain characteristics are all computed for multiple curvature cases and different stenotic depths. Factors such as blood viscosity, density and its non-Newtonian behaviour due to red blood cells are considered. FSI analysis extends CFD by including the interaction between blood flow and deformable (elastic) arterial walls, accounting for the arterial mechanical properties and the flow-induced pressure changes. Here we do not consider the two-way case where deformation in turn affects the flow, only the one-way (monolithic) case where the blood flow distorts the arterial wall. This approach allows for deeper insight into the interaction between rheological blood flow and elastic arterial walls which aids in highlighting high stress zones, recirculation and hemodynamic impedance of potential use in identifying rupture or plaque formation, contributing significantly to the management and prevention of CVDs.


  • Open Access

    Electro-osmotically Modulated Viscoelastic SWCNT-Blood flow in Symmetric/Nonsymmetric Stenosed Arteries with heat generation using a Fractional Second Grade Model

    by Mahadev M Channakote, O. Anwar Bég, S. Kuharat, M. Shekar, C. Siddabasappa

    The current study aims to analyse the electro-osmotically driven non-Newtonian blood flow containing single-walled carbon nanotubes (SWCNTs) in symmetric and non-symmetric stenosed arteries. This nanoscale formulation considers the impact of SWCNTs on flow characteristics, with a key focus on the thermal and electrical properties of blood. The fractional viscoelastic second grade Reiner-Rivlin differential model is deployed for rheological effects and employs Caputo's definition. Heat generation and thermal buoyancy (natural convection) are also considered. The Debye-Hückel linearization approximation is used to analyse the electro-osmotic dynamics. The system of partial differential equations relevant to the problem is simplified to an ordinary differential equation system by virtue of suitable scaling transformations. Analytical solutions are derived for the non-dimensional boundary value problem. Axial velocity, temperature, electrical potential, volumetric flow rate, axial pressure gradient, pressure rise, and wall shear stress have been computed and selected characteristics have been visualized with the aid of graphs using Mathematica software. The computations show that there is a depletion in the velocity at the walls whereas there is a strong elevation in the core zone for both symmetric (n=2) and non-symmetric (n=6) shapes of stenosis with increasing positive values of Helmholtz-Smoluchowski velocity (UHS), non-Newtonian fractional viscoelastic parameter (λ), carbon nanotube (CNT) volume fraction (ϕ), electro-osmotic Debye length parameter (m) and stenosis height (ϵ). With increasing heat generation parameter (β>0), axial velocity is enhanced across the arterial section and temperature is enhanced. Temperature and wall shear stress (τ_w ) are both strongly reduced with greater carbon nanotube (CNT) volume fraction (ϕ). An increment in volume flow rate (Q) and stenosis height (ϵ) enhances wall shear stress values. A non-symmetric shape of stenosis (n =6) generally produces higher temperatures than the symmetric shape case (n =2). An assessment of trapping phenomena shows that size and number of trapping boluses are increased with higher volumetric flow rate (Q) for both the non-symmetric and symmetric stenotic cases.

  • Open Access

    Finite element stress analysis and topological optimization of a commercial aircraft seat structure

    by Christian Amaze, Sireetorn Kuharat, O. Anwar Bég, Ali Kadir, Walid Jouri, Tasveer A. Bég

    In recent years, the Finite Element Method (FEM) has emerged as a cornerstone in the field of seating design, particularly within the aircraft industry. Over the past decade, significant advancements in Finite Element (FE) analysis techniques have revolutionized the seat industry, enabling the creation of safer and more cost-effective seat designs. The accuracy of FE analysis plays a pivotal role in this transformation. In the process of constructing a reliable finite element model, the selection and precise manipulation of key parameters are paramount. These crucial parameters encompass element size, time scale, analysis type, and material model. Properly defining and implementing these parameters ensures that the FE model produces accurate results, closely mirroring real-world performance. Verification of Finite Element Analysis (FEA) results is commonly accomplished through experimental methods. Notably, when the parameters are appropriately integrated into the modelling process, FE analysis outcomes closely align with experimental results. This study aims to leverage the power of FEM in performing static stress analysis and topology optimization of aircraft seats using the SOLIDWORKS commercial finite element platform. By simulating loading conditions, this research calculates static stresses and displacements experienced by the aircraft seat. Through a comprehensive topology optimization study, the weight of the airplane seat is remarkably reduced by up to 30%, while still prioritizing passenger safety. The success of this optimization showcases the potential for substantial weight savings in aircraft seat design without compromising safety standards.