Shuhua Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuhua Xiao has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Botao Zhang
Guangzhou Electric Power Design Institute Co., Ltd., Guangzhou 510060, China
1 shared publication - Caiyan Lin
Guangdong Power Grid Huizhou Power Supply Bureau, Huizhou 516000, China
1 shared publication - Guoliang Huang
Guangdong Power Grid Huizhou Power Supply Bureau, Huizhou 516000, China
1 shared publication - Ji Shi
Guangdong Power Grid Huizhou Power Supply Bureau, Huizhou 516000, China
1 shared publication - Jialing Yang
School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou 510006, China
1 shared publication - Junhong Zhou
Huizhou Power Supply Bureau, Guangdong Power Grid Co., Ltd., China Southern Power Grid Co., Ltd., Huizhou 516000, China
1 shared publication
Latest Publications
- Open Access
Seismic Performance of Beam–Column Joints in Seawater Sand Concrete Reinforced with Steel-FRP Composite Bars
Steel fiber-reinforced polymer (FRP) composite bars (SFCBs) combine the ductility of steel reinforcement with the corrosion resistance and high strength of FRP, providing stable secondary stiffness that enhances the seismic resistance and safety of seawater sea–sand concrete structures. However, the seismic performance of SFCB-reinforced seawater sea–sand concrete beam–column joints remains underexplored. This study presents pseudo-static tests on SFCB-reinforced beam–column joints with varying column SFCB longitudinal reinforcement fiber volume ratios (64%, 75%, and 84%), beam reinforcement fiber volume ratios (60.9%, 75%, and 86%), and axial compression ratios (0.1 and 0.2). The results indicate that increasing the axial compression ratio enhances nodal shear capacity and bond strength, limits slip, and reduces crack propagation, but also accelerates bearing capacity degradation. Higher column reinforcement fiber volumes improve crack distribution and ductility, while beam reinforcement volume significantly affects energy dissipation and crack distribution, with moderate volumes (e.g., 75%) yielding optimal seismic performance. These findings provide insights for the seismic design of SFCB-composite-reinforced concrete structures in marine environments.
Open AccessSeismic Performance of Beam–Column Joints in Seawater Sand Concrete Reinforced with Steel-FRP Composite Bars
Steel fiber-reinforced polymer (FRP) composite bars (SFCBs) combine the ductility of steel reinforcement with the corrosion resistance and high strength of FRP, providing stable secondary stiffness that enhances the seismic resistance and safety of seawater sea–sand concrete structures. However, the seismic performance of SFCB-reinforced seawater sea–sand concrete beam–column joints remains underexplored. This study presents pseudo-static tests on SFCB-reinforced beam–column joints with varying column SFCB longitudinal reinforcement fiber volume ratios (64%, 75%, and 84%), beam reinforcement fiber volume ratios (60.9%, 75%, and 86%), and axial compression ratios (0.1 and 0.2). The results indicate that increasing the axial compression ratio enhances nodal shear capacity and bond strength, limits slip, and reduces crack propagation, but also accelerates bearing capacity degradation. Higher column reinforcement fiber volumes improve crack distribution and ductility, while beam reinforcement volume significantly affects energy dissipation and crack distribution, with moderate volumes (e.g., 75%) yielding optimal seismic performance. These findings provide insights for the seismic design of SFCB-composite-reinforced concrete structures in marine environments.
- Open Access
A Sustainable Steel-GFRP Composite Bars Reinforced Concrete Structure: Investigation of the Bonding Performance
Steel-fiber reinforced polymer (FRP) composite bars (SFCBs) can enhance the controllability of damage in concrete structures; thus, studying the interfacial bonding between them is fundamental and a prerequisite for achieving deformation coordination and collaboration. However, research on the interfacial bonding performance between SFCBs and concrete remains inadequate. This study conducted central pullout tests on SFCB-concrete specimens with different concrete strengths (C30, C50, and C70), bar diameters (12, 16 and 20 mm), and hoop reinforcement constraints, analyzing variations in failure modes, bond-slip curves, bond strength, etc. Additionally, finite element simulations were performed using ABAQUS software to further validate the bonding mechanism of SFCB-concrete. The results showed that the failure mode of the specimens was related to the confinement effect on the bars. Insufficient concrete cover and lack of hoop restraint led to splitting failure, whereas pullout failure occurred otherwise. For the specimens with pullout failure, the interfacial damage between the SFCB and concrete was mainly caused by the surface fibers wear of the bar and the shear of the concrete lugs, which indicated that the bond of the SFCB-concrete interface consisted mainly of mechanical interlocking forces. In addition, the variation of concrete strength as well as bar diameter did not affect the bond-slip relationship of SFCB-concrete. However, the bond strength of SFCB-concrete increased with the increase of concrete strength. For example, compared with C30 concrete, when the concrete strength was increased to C70, the bond strength of the specimens under the same conditions was increased to 50–101.6%. In contrast, the bond strength of the specimens decreased by 13.29–28.71% when the bar diameter was increased from 12 to 14 mm. These discoveries serve as valuable references for the implementation of sustainable SFCB-reinforced concrete structures.
Open AccessA Sustainable Steel-GFRP Composite Bars Reinforced Concrete Structure: Investigation of the Bonding Performance
Steel-fiber reinforced polymer (FRP) composite bars (SFCBs) can enhance the controllability of damage in concrete structures; thus, studying the interfacial bonding between them is fundamental and a prerequisite for achieving deformation coordination and collaboration. However, research on the interfacial bonding performance between SFCBs and concrete remains inadequate. This study conducted central pullout tests on SFCB-concrete specimens with different concrete strengths (C30, C50, and C70), bar diameters (12, 16 and 20 mm), and hoop reinforcement constraints, analyzing variations in failure modes, bond-slip curves, bond strength, etc. Additionally, finite element simulations were performed using ABAQUS software to further validate the bonding mechanism of SFCB-concrete. The results showed that the failure mode of the specimens was related to the confinement effect on the bars. Insufficient concrete cover and lack of hoop restraint led to splitting failure, whereas pullout failure occurred otherwise. For the specimens with pullout failure, the interfacial damage between the SFCB and concrete was mainly caused by the surface fibers wear of the bar and the shear of the concrete lugs, which indicated that the bond of the SFCB-concrete interface consisted mainly of mechanical interlocking forces. In addition, the variation of concrete strength as well as bar diameter did not affect the bond-slip relationship of SFCB-concrete. However, the bond strength of SFCB-concrete increased with the increase of concrete strength. For example, compared with C30 concrete, when the concrete strength was increased to C70, the bond strength of the specimens under the same conditions was increased to 50–101.6%. In contrast, the bond strength of the specimens decreased by 13.29–28.71% when the bar diameter was increased from 12 to 14 mm. These discoveries serve as valuable references for the implementation of sustainable SFCB-reinforced concrete structures.