Tanzim Jim Hassan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tanzim Jim Hassan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Akshay Ram Ramchandra
School of Electrical Engineering and Computer Science, University of North Dakota, Grand Forks, ND, USA
1 shared publication- Alain J. Kassab
Centecorp LLC , 147 Parsons Rd, Longwood, FL 32779 , USA
1 shared publication Barathwaja Subash Chandar
School of Electrical Engineering and Computer Science, University of North Dakota, Grand Forks, ND, USA
1 shared publication- Charles T. Price
International Hip Dysplasia Institute, Orlando, FL, USA
1 shared publication F. Moslehy
University of Central Florida,Department of Mechanical and Aerospace Engineering,Orlando,Florida,USA
1 shared publication- Farishta Rahman
School of Electrical Engineering and Computer Science, University of North Dakota, Grand Forks, ND, USA
1 shared publication
Latest Publications
- Open Access
- 29 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 82289-82317
UAS-Guided Analysis of Electric and Magnetic Field Distribution in High-Voltage Transmission Lines (Tx) and Multi-Stage Hybrid Machine Learning Models for Battery Drain Estimation
Unmanned aerial systems/vehicles (UAS/UAVs) are widely employed for inspecting high-voltage (HV) Tx lines, characterized by elevated electric (E) and magnetic (H) fields. Operating on batteries, these UAVs are equipped with various electrical sensors, microprocessors, and motors, all susceptible to E/H field effects. This paper explores the distribution of E/H fields in multiple HVTx lines and a microwave tower. Data was collected from one 250 kV DC , four AC Tx lines (69kV, 230kV, 345kV, and 500kV), and one microwave tower, utilizing DJI UAVs (M2EA, M30, and M300) equipped with onboard setups. Measurements included E field in V/m, H field in mG, Battery voltage in V, Battery current in A, Battery percentage, Battery Temperature in F, latitude, and longitude. Preliminary findings highlight larger E/H field levels within AC Tx lines than DC Tx lines. The paper discusses conditions influencing E/H field strength during UAV operation. Additionally, a proposed multi-staged random forest regressor (RFR) and k-nearest neighbor (KNN) hybrid machine learning (ML) model forecasts UAV battery drain. Results indicate that the hybrid RFR and KNN model yields lower MAPE values compared to standalone models.
- 29 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 82289-82317
Open AccessUAS-Guided Analysis of Electric and Magnetic Field Distribution in High-Voltage Transmission Lines (Tx) and Multi-Stage Hybrid Machine Learning Models for Battery Drain Estimation
Unmanned aerial systems/vehicles (UAS/UAVs) are widely employed for inspecting high-voltage (HV) Tx lines, characterized by elevated electric (E) and magnetic (H) fields. Operating on batteries, these UAVs are equipped with various electrical sensors, microprocessors, and motors, all susceptible to E/H field effects. This paper explores the distribution of E/H fields in multiple HVTx lines and a microwave tower. Data was collected from one 250 kV DC , four AC Tx lines (69kV, 230kV, 345kV, and 500kV), and one microwave tower, utilizing DJI UAVs (M2EA, M30, and M300) equipped with onboard setups. Measurements included E field in V/m, H field in mG, Battery voltage in V, Battery current in A, Battery percentage, Battery Temperature in F, latitude, and longitude. Preliminary findings highlight larger E/H field levels within AC Tx lines than DC Tx lines. The paper discusses conditions influencing E/H field strength during UAV operation. Additionally, a proposed multi-staged random forest regressor (RFR) and k-nearest neighbor (KNN) hybrid machine learning (ML) model forecasts UAV battery drain. Results indicate that the hybrid RFR and KNN model yields lower MAPE values compared to standalone models.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A System for Measuring Sound Transmission Through Joints
Sound transmission in the human body can be affected by the tissue composition along the sound path and surrounding structures. Therefore, acoustic transmission may correlate with pathologies involving structural changes. Previous studies utilized sound transmission to detect a variety of pulmonary, gastrointestinal, vascular, cardiac conditions, and developmental dysplasia of the hip (DDH) [1] [2] [3] [4] [5] [6] . The objective of this study is to design and test a reliable system capable of providing adequate acoustic stimulus, and simultaneously measure transmitted signals at multiple skin surface locations. The study objectives include determining: (1) the static load needed to reach a target SNR (>20 dB) at the measurement points and a target coherence (>0.8) between excitation and measurement points; (2) the exciter sensitivity to static load changes; and (3) the exciter input maximum power and corresponding acceleration. These results will help guide the choice of optimal exciter that: (1) can withstand sufficient static load (~500g), which would provide coupling to the bone to reach a target SNR and coherence; (2) has low sensitivity to load (low variability for a load change ~100 gm); (3) can provide sufficient acoustic excitation energy to maintain the target SNR and coherence; (4) be available at a reasonable cost (~<$500); (5) ensures patient comfort (with no subject discomfort reported for a contact area of ~ 2 cm 2 ).
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A System for Measuring Sound Transmission Through Joints
Sound transmission in the human body can be affected by the tissue composition along the sound path and surrounding structures. Therefore, acoustic transmission may correlate with pathologies involving structural changes. Previous studies utilized sound transmission to detect a variety of pulmonary, gastrointestinal, vascular, cardiac conditions, and developmental dysplasia of the hip (DDH) [1] [2] [3] [4] [5] [6] . The objective of this study is to design and test a reliable system capable of providing adequate acoustic stimulus, and simultaneously measure transmitted signals at multiple skin surface locations. The study objectives include determining: (1) the static load needed to reach a target SNR (>20 dB) at the measurement points and a target coherence (>0.8) between excitation and measurement points; (2) the exciter sensitivity to static load changes; and (3) the exciter input maximum power and corresponding acceleration. These results will help guide the choice of optimal exciter that: (1) can withstand sufficient static load (~500g), which would provide coupling to the bone to reach a target SNR and coherence; (2) has low sensitivity to load (low variability for a load change ~100 gm); (3) can provide sufficient acoustic excitation energy to maintain the target SNR and coherence; (4) be available at a reasonable cost (~<$500); (5) ensures patient comfort (with no subject discomfort reported for a contact area of ~ 2 cm 2 ).