Jean Christophe Marie Richard
Jean Christophe Marie Richard has a total of 156 co-authors. Here are the top co-authors by number of shared publications:
- Laurent Brochard
Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada
7 shared publications Alain Mercat
Vent'Lab, Medical Intensive Care Unit, Angers University Hospital, Angers, France; Medical intensive care unit, Angers University Hospital, Angers, France
6 shared publicationsLaurent Brochard
Keenan Research Centre, Li Ka Shing Knowledge Institute, St. Michael's Hospital, Unity Health, Toronto, Ontario, Canada; Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Ontario, Canada
5 shared publications- Alain Mercat
Department of Medical Intensive Care, University Hospital of Angers, CARE, SFR ICAT, Angers, France
3 shared publications Alice Hutin
National veterinary school of Alfort, IMRB, AfterROSC Network, 94700 Maisons-Alfort, France; SAMU of Paris and intensive care unit, Necker University Hospital, Assistance Publique-Hôpitaux de Paris (APHP), Paris 75015, France
3 shared publicationsArnaud Lesimple
Vent'Lab, Medical Intensive Care Unit, Angers University Hospital, Angers, France; Med(2)Lab laboratory, Air Liquide Medical Systems, Antony, France
3 shared publications
Latest Publications
- Open Access
- 17 March 2026
- Published by Elsevier in Resuscitation
- Vol. 223, 111062
Impact of tidal volume during cardiopulmonary resuscitation: an experimental pilot porcine study
- 17 March 2026
- Published by Elsevier in Resuscitation
- Vol. 223, 111062
Open AccessImpact of tidal volume during cardiopulmonary resuscitation: an experimental pilot porcine study
- Open Access
- 17 September 2024
- Published by Springer Nature in Intensive Care Medicine
- Vol. 50 (10) , 1647-1656
Pressure control plus spontaneous ventilation versus volume assist-control ventilation in acute respiratory distress syndrome. A randomised clinical trial
Purpose The aim of this study was to compare the effect of a pressure-controlled strategy allowing non-synchronised unassisted spontaneous ventilation (PC-SV) to a conventional volume assist-control strategy (ACV) on the outcome of patients with acute respiratory distress syndrome (ARDS). Methods Open-label randomised clinical trial in 22 intensive care units (ICU) in France. Seven hundred adults with moderate or severe ARDS (PaO2/FiO2 < 200 mmHg) were enrolled from February 2013 to October 2018. Patients were randomly assigned to PC-SV (n = 348) or ACV (n = 352) with similar objectives of tidal volume (6 mL/kg predicted body weight) and positive end-expiratory pressure (PEEP). Paralysis was stopped after 24 h and sedation adapted to favour patients’ spontaneous ventilation. The primary endpoint was in-hospital death from any cause at day 60. Results Hospital mortality [34.6% vs 33.5%, p = 0.77, risk ratio (RR) = 1.03 (95% confidence interval [CI] 0.84–1.27)], 28-day mortality, as well as the number of ventilator-free days and organ failure-free days at day 28 did not differ between PC-SV and ACV groups. Patients in the PC-SV group received significantly less sedation and neuro-muscular blocking agents than in the ACV group. A lower proportion of patients required adjunctive therapy of hypoxemia (including prone positioning) in the PC-SV group than in the ACV group [33.1% vs 41.3%, p = 0.03, RR = 0.80 (95% CI 0.66–0.98)]. The incidences of pneumothorax and refractory hypoxemia did not differ between the groups. Conclusions A strategy based on PC-SV mode that favours spontaneous ventilation reduced the need for sedation and adjunctive therapies of hypoxemia but did not significantly reduce mortality compared to ACV with similar tidal volume and PEEP levels.
- 17 September 2024
- Published by Springer Nature in Intensive Care Medicine
- Vol. 50 (10) , 1647-1656
Open AccessPressure control plus spontaneous ventilation versus volume assist-control ventilation in acute respiratory distress syndrome. A randomised clinical trial
Purpose The aim of this study was to compare the effect of a pressure-controlled strategy allowing non-synchronised unassisted spontaneous ventilation (PC-SV) to a conventional volume assist-control strategy (ACV) on the outcome of patients with acute respiratory distress syndrome (ARDS). Methods Open-label randomised clinical trial in 22 intensive care units (ICU) in France. Seven hundred adults with moderate or severe ARDS (PaO2/FiO2 < 200 mmHg) were enrolled from February 2013 to October 2018. Patients were randomly assigned to PC-SV (n = 348) or ACV (n = 352) with similar objectives of tidal volume (6 mL/kg predicted body weight) and positive end-expiratory pressure (PEEP). Paralysis was stopped after 24 h and sedation adapted to favour patients’ spontaneous ventilation. The primary endpoint was in-hospital death from any cause at day 60. Results Hospital mortality [34.6% vs 33.5%, p = 0.77, risk ratio (RR) = 1.03 (95% confidence interval [CI] 0.84–1.27)], 28-day mortality, as well as the number of ventilator-free days and organ failure-free days at day 28 did not differ between PC-SV and ACV groups. Patients in the PC-SV group received significantly less sedation and neuro-muscular blocking agents than in the ACV group. A lower proportion of patients required adjunctive therapy of hypoxemia (including prone positioning) in the PC-SV group than in the ACV group [33.1% vs 41.3%, p = 0.03, RR = 0.80 (95% CI 0.66–0.98)]. The incidences of pneumothorax and refractory hypoxemia did not differ between the groups. Conclusions A strategy based on PC-SV mode that favours spontaneous ventilation reduced the need for sedation and adjunctive therapies of hypoxemia but did not significantly reduce mortality compared to ACV with similar tidal volume and PEEP levels.
- Open Access
- 30 April 2024
- Published by Springer Nature in Research Square
Pressure versus volume assist-control ventilation in Acute Respiratory Distress Syndrome: a randomised clinical trial.
Background: To compare the effect of a pressure-controlled strategy allowing non-synchronized unassisted spontaneous ventilation (PC-SV) to a conventional volume assist-control strategy (ACV) on the outcome of patients with Acute Respiratory Distress Syndrome (ARDS). Methods: Open-label randomized clinical trial in 22 ICUs in France. Seven hundred adults with moderate or severe ARDS (PaO2/FiO2 < 200 mmHg) were enrolled from February 2013 to October 2018. Patients were randomly assigned to PC-SV (n=348) or ACV (n=352) with similar objectives of tidal volume (6 mL/kg predicted body weight) and positive end-expiratory pressure (PEEP). Paralysis was stopped after 24h and sedation adapted to favour patients’ spontaneous ventilation. The primary endpoint was in-hospital death from any cause at day 60. Findings: Hospital mortality (34.6% vs 33.5%, p=.77, RR=1.03 (95% CI, 0.84-1.27)), 28-day mortality, as well as the number of ventilator-free days and organ failure-free days at day 28 did not differ between PC-SV and ACV groups. Patients in the PC-SV group received significantly less sedation and neuro-muscular blocking agents than in the ACV group. A lower proportion of patients required adjunctive therapy of hypoxemia (including prone positioning) in the PC-SV group than in the ACV group (33.1% vs 41.3%, p=.03, RR=0.80 (95% CI, 0.66-0.98)). The incidences of pneumothorax and refractory hypoxemia did not differ between the groups. Interpretation: A strategy based on a pressure-controlled mode that favours spontaneous ventilation did not significantly reduce mortality compared to ACV with similar tidal volume and PEEP levels but reduced the need for sedation and adjunctive therapies of hypoxemia. Funding: French Ministry of Health (PHRC 49RC-09-04-01) Trial registration: ClinicalTrials.gov Identifier: NCT01862016
- 30 April 2024
- Published by Springer Nature in Research Square
Open AccessPressure versus volume assist-control ventilation in Acute Respiratory Distress Syndrome: a randomised clinical trial.
Background: To compare the effect of a pressure-controlled strategy allowing non-synchronized unassisted spontaneous ventilation (PC-SV) to a conventional volume assist-control strategy (ACV) on the outcome of patients with Acute Respiratory Distress Syndrome (ARDS). Methods: Open-label randomized clinical trial in 22 ICUs in France. Seven hundred adults with moderate or severe ARDS (PaO2/FiO2 < 200 mmHg) were enrolled from February 2013 to October 2018. Patients were randomly assigned to PC-SV (n=348) or ACV (n=352) with similar objectives of tidal volume (6 mL/kg predicted body weight) and positive end-expiratory pressure (PEEP). Paralysis was stopped after 24h and sedation adapted to favour patients’ spontaneous ventilation. The primary endpoint was in-hospital death from any cause at day 60. Findings: Hospital mortality (34.6% vs 33.5%, p=.77, RR=1.03 (95% CI, 0.84-1.27)), 28-day mortality, as well as the number of ventilator-free days and organ failure-free days at day 28 did not differ between PC-SV and ACV groups. Patients in the PC-SV group received significantly less sedation and neuro-muscular blocking agents than in the ACV group. A lower proportion of patients required adjunctive therapy of hypoxemia (including prone positioning) in the PC-SV group than in the ACV group (33.1% vs 41.3%, p=.03, RR=0.80 (95% CI, 0.66-0.98)). The incidences of pneumothorax and refractory hypoxemia did not differ between the groups. Interpretation: A strategy based on a pressure-controlled mode that favours spontaneous ventilation did not significantly reduce mortality compared to ACV with similar tidal volume and PEEP levels but reduced the need for sedation and adjunctive therapies of hypoxemia. Funding: French Ministry of Health (PHRC 49RC-09-04-01) Trial registration: ClinicalTrials.gov Identifier: NCT01862016
- Open Access
- 13 June 2023
- Published by Societe de Reanimation de Langue Francaise in Médecine Intensive Réanimation
- Vol. 32 (Hors-série) , 39-50
La ventilation en pression positive : de la ventilation manuelle aux ventilateurs modernes.
La ventilation en pression positive est née dans les années 50 à l’occasion de l’épidémie de poliomyélite devant l’impérieuse nécessité de prendre en charge un afflux massif de patients en détresse respiratoire. Des solutions technologiques et organisationnelles, pragmatiques, basées sur le besoin, ont été mises en place donnant ainsi naissance à la réanimation. Par la suite, l’innovation s’est organisée et industrialisée. Les ventilateurs de réanimation ont progressé de générations en générations, pour accompagner l’incroyable explosion des connaissances autour de la ventilation. De la pression expiratoire positive à la ventilation non invasive, les ventilateurs se sont modernisés. Ils embarquent aujourd’hui de multiples possibilités de traitements qui ont transformé le pronostic des malades de réanimation. La récente pandémie COVID-19 nous a rappelé que l’histoire n’était pas finie. Des solutions innovantes plus sobres, plus flexibles, mais tout aussi efficaces voient le jour pour couvrir les besoins qui ne cessent d’augmenter.
- 13 June 2023
- Published by Societe de Reanimation de Langue Francaise in Médecine Intensive Réanimation
- Vol. 32 (Hors-série) , 39-50
Open AccessLa ventilation en pression positive : de la ventilation manuelle aux ventilateurs modernes.
La ventilation en pression positive est née dans les années 50 à l’occasion de l’épidémie de poliomyélite devant l’impérieuse nécessité de prendre en charge un afflux massif de patients en détresse respiratoire. Des solutions technologiques et organisationnelles, pragmatiques, basées sur le besoin, ont été mises en place donnant ainsi naissance à la réanimation. Par la suite, l’innovation s’est organisée et industrialisée. Les ventilateurs de réanimation ont progressé de générations en générations, pour accompagner l’incroyable explosion des connaissances autour de la ventilation. De la pression expiratoire positive à la ventilation non invasive, les ventilateurs se sont modernisés. Ils embarquent aujourd’hui de multiples possibilités de traitements qui ont transformé le pronostic des malades de réanimation. La récente pandémie COVID-19 nous a rappelé que l’histoire n’était pas finie. Des solutions innovantes plus sobres, plus flexibles, mais tout aussi efficaces voient le jour pour couvrir les besoins qui ne cessent d’augmenter.
- Open Access
- 30 November 2022
- Published by MDPI AG in Healthcare
- Vol. 10 (12) , 2416
Responses of Bilevel Ventilators to Unintentional Leak: A Bench Study
Background: The impact of leaks has mainly been assessed in bench models using continuous leak patterns which did not reflect real-life leakage. We aimed to assess the impact of the pattern and intensity of unintentional leakage (UL) using several respiratory models. Methods: An active artificial lung (ASL 5000) was connected to three bilevel-ventilators set in pressure mode; the experiments were carried out with three lung mechanics (COPD, OHS and NMD) with and without upper airway obstruction. Triggering delay, work of breathing, pressure rise time, inspiratory pressure, tidal volume, cycling delay and the asynchrony index were measured at 0, 6, 24 and 36 L/min of UL. We generated continuous and inspiratory UL. Results: Compared to 0 L/min of UL, triggering delays were significantly higher with 36 L/min of UL (+27 ms) and pressure rise times were longer (+71 ms). Cycling delays increased from −4 [−250–169] ms to 150 [−173–207] ms at, respectively 0 L/min and 36 L/min of UL and work of breathing increased from 0.15 [0.12–0.29] J/L to 0.19 [0.16–0.36] J/L. Inspiratory leakage pattern significantly increased triggering delays (+35 ms) and cycling delays (+263 ms) but decreased delivered pressure (−0.94 cmH2O) compared to continuous leakage pattern. Simulated upper airway obstruction significantly increased triggering delay (+199 ms), cycling delays (+371 ms), and decreased tidal volume (−407 mL) and pressure rise times (−56 ms). Conclusions: The pattern of leakage impacted more the device performances than the magnitude of the leakage per se. Flow limitation negatively reduced all ventilator performances.
- 30 November 2022
- Published by MDPI AG in Healthcare
- Vol. 10 (12) , 2416
Open AccessResponses of Bilevel Ventilators to Unintentional Leak: A Bench Study
Background: The impact of leaks has mainly been assessed in bench models using continuous leak patterns which did not reflect real-life leakage. We aimed to assess the impact of the pattern and intensity of unintentional leakage (UL) using several respiratory models. Methods: An active artificial lung (ASL 5000) was connected to three bilevel-ventilators set in pressure mode; the experiments were carried out with three lung mechanics (COPD, OHS and NMD) with and without upper airway obstruction. Triggering delay, work of breathing, pressure rise time, inspiratory pressure, tidal volume, cycling delay and the asynchrony index were measured at 0, 6, 24 and 36 L/min of UL. We generated continuous and inspiratory UL. Results: Compared to 0 L/min of UL, triggering delays were significantly higher with 36 L/min of UL (+27 ms) and pressure rise times were longer (+71 ms). Cycling delays increased from −4 [−250–169] ms to 150 [−173–207] ms at, respectively 0 L/min and 36 L/min of UL and work of breathing increased from 0.15 [0.12–0.29] J/L to 0.19 [0.16–0.36] J/L. Inspiratory leakage pattern significantly increased triggering delays (+35 ms) and cycling delays (+263 ms) but decreased delivered pressure (−0.94 cmH2O) compared to continuous leakage pattern. Simulated upper airway obstruction significantly increased triggering delay (+199 ms), cycling delays (+371 ms), and decreased tidal volume (−407 mL) and pressure rise times (−56 ms). Conclusions: The pattern of leakage impacted more the device performances than the magnitude of the leakage per se. Flow limitation negatively reduced all ventilator performances.
- Open Access
- 23 September 2022
- Published by Springer Nature in Critical Care
- Vol. 26 (1) , 1-13
A novel capnogram analysis to guide ventilation during cardiopulmonary resuscitation: clinical and experimental observations
Background: Cardiopulmonary resuscitation (CPR) decreases lung volume below the functional residual capacity and can generate intrathoracic airway closure. Conversely, large insufflations can induce thoracic distension and jeopardize circulation. The capnogram (CO2 signal) obtained during continuous chest compressions can reflect intrathoracic airway closure, and we hypothesized here that it can also indicate thoracic distension. Objectives: To test whether a specific capnogram may identify thoracic distension during CPR and to assess the impact of thoracic distension on gas exchange and hemodynamics. Methods: (1) In out-of-hospital cardiac arrest patients, we identified on capnograms three patterns: intrathoracic airway closure, thoracic distension or regular pattern. An algorithm was designed to identify them automatically. (2) To link CO2 patterns with ventilation, we conducted three experiments: (i) reproducing the CO2 patterns in human cadavers, (ii) assessing the influence of tidal volume and respiratory mechanics on thoracic distension using a mechanical lung model and (iii) exploring the impact of thoracic distension patterns on different circulation parameters during CPR on a pig model. Measurements and main results: (1) Clinical data: 202 capnograms were collected. Intrathoracic airway closure was present in 35%, thoracic distension in 22% and regular pattern in 43%. (2) Experiments: (i) Higher insufflated volumes reproduced thoracic distension CO2 patterns in 5 cadavers. (ii) In the mechanical lung model, thoracic distension patterns were associated with higher volumes and longer time constants. (iii) In six pigs during CPR with various tidal volumes, a CO2 pattern of thoracic distension, but not tidal volume per se, was associated with a significant decrease in blood pressure and cerebral perfusion. Conclusions: During CPR, capnograms reflecting intrathoracic airway closure, thoracic distension or regular pattern can be identified. In the animal experiment, a thoracic distension pattern on the capnogram is associated with a negative impact of ventilation on blood pressure and cerebral perfusion during CPR, not predicted by tidal volume per se.
- 23 September 2022
- Published by Springer Nature in Critical Care
- Vol. 26 (1) , 1-13
Open AccessA novel capnogram analysis to guide ventilation during cardiopulmonary resuscitation: clinical and experimental observations
Background: Cardiopulmonary resuscitation (CPR) decreases lung volume below the functional residual capacity and can generate intrathoracic airway closure. Conversely, large insufflations can induce thoracic distension and jeopardize circulation. The capnogram (CO2 signal) obtained during continuous chest compressions can reflect intrathoracic airway closure, and we hypothesized here that it can also indicate thoracic distension. Objectives: To test whether a specific capnogram may identify thoracic distension during CPR and to assess the impact of thoracic distension on gas exchange and hemodynamics. Methods: (1) In out-of-hospital cardiac arrest patients, we identified on capnograms three patterns: intrathoracic airway closure, thoracic distension or regular pattern. An algorithm was designed to identify them automatically. (2) To link CO2 patterns with ventilation, we conducted three experiments: (i) reproducing the CO2 patterns in human cadavers, (ii) assessing the influence of tidal volume and respiratory mechanics on thoracic distension using a mechanical lung model and (iii) exploring the impact of thoracic distension patterns on different circulation parameters during CPR on a pig model. Measurements and main results: (1) Clinical data: 202 capnograms were collected. Intrathoracic airway closure was present in 35%, thoracic distension in 22% and regular pattern in 43%. (2) Experiments: (i) Higher insufflated volumes reproduced thoracic distension CO2 patterns in 5 cadavers. (ii) In the mechanical lung model, thoracic distension patterns were associated with higher volumes and longer time constants. (iii) In six pigs during CPR with various tidal volumes, a CO2 pattern of thoracic distension, but not tidal volume per se, was associated with a significant decrease in blood pressure and cerebral perfusion. Conclusions: During CPR, capnograms reflecting intrathoracic airway closure, thoracic distension or regular pattern can be identified. In the animal experiment, a thoracic distension pattern on the capnogram is associated with a negative impact of ventilation on blood pressure and cerebral perfusion during CPR, not predicted by tidal volume per se.
- Open Access
- 7 July 2022
- Published by Springer Nature in Research Square
A novel capnogram analysis to guide ventilation during continuous chest compressions resuscitation. From clinical to experimental observations
Background: Cardio-Pulmonary Resuscitation (CPR) decreases lung volume below the functional residual capacity and can generate intrathoracic airway closure. Conversely, large insufflations can induce thoracic distension and jeopardize circulation. The capnogram (CO2 signal) obtained during continuous chest compressions can reflect intrathoracic airway closure and we hypothesized here that it can also indicate thoracic distension. Objectives: to test whether a specific capnogram may identify thoracic distension during CPR and assess its impact on gas exchange and hemodynamics. Methods: 1. In out-of-hospital cardiac arrest patients, we identified on capnograms three patterns: intrathoracic airway closure, thoracic distension or regular pattern. An algorithm was designed to identify them automatically.2. To link CO2 patterns with ventilation, we conducted three experiments:i) Reproducing the CO2 patterns in human cadavers. ii) Assessing the influence of tidal volume and respiratory mechanics on thoracic distension using a mechanical lung model. iii) Exploring the impact of thoracic distension patterns on different circulation parameters during CPR on a pig model. Measurements and main results: Clinical data: 202 patients were included. Intrathoracic airway closure was present in 35%, thoracic distension in 22% and regular pattern in 43%. Experiments:i) Higher insufflated volumes reproduced thoracic distension CO2 patterns in 5 cadavers. ii) In the mechanical lung model, thoracic distension patterns were associated with higher volumes and longer time constants. iii) In six pigs during CPR with various tidal volumes, a CO2 pattern of thoracic distension, but not tidal volume per se, was associated with a significant decrease in blood pressure and cerebral perfusion. Conclusions: During CPR, intrathoracic airway closure, thoracic distension or regular pattern can be identified by capnogram analysis. A thoracic distension pattern on the capnogram may indicate a negative impact of ventilation on blood pressure and cerebral perfusion during CPR, not predicted by tidal volume per se.
- 7 July 2022
- Published by Springer Nature in Research Square
Open AccessA novel capnogram analysis to guide ventilation during continuous chest compressions resuscitation. From clinical to experimental observations
Background: Cardio-Pulmonary Resuscitation (CPR) decreases lung volume below the functional residual capacity and can generate intrathoracic airway closure. Conversely, large insufflations can induce thoracic distension and jeopardize circulation. The capnogram (CO2 signal) obtained during continuous chest compressions can reflect intrathoracic airway closure and we hypothesized here that it can also indicate thoracic distension. Objectives: to test whether a specific capnogram may identify thoracic distension during CPR and assess its impact on gas exchange and hemodynamics. Methods: 1. In out-of-hospital cardiac arrest patients, we identified on capnograms three patterns: intrathoracic airway closure, thoracic distension or regular pattern. An algorithm was designed to identify them automatically.2. To link CO2 patterns with ventilation, we conducted three experiments:i) Reproducing the CO2 patterns in human cadavers. ii) Assessing the influence of tidal volume and respiratory mechanics on thoracic distension using a mechanical lung model. iii) Exploring the impact of thoracic distension patterns on different circulation parameters during CPR on a pig model. Measurements and main results: Clinical data: 202 patients were included. Intrathoracic airway closure was present in 35%, thoracic distension in 22% and regular pattern in 43%. Experiments:i) Higher insufflated volumes reproduced thoracic distension CO2 patterns in 5 cadavers. ii) In the mechanical lung model, thoracic distension patterns were associated with higher volumes and longer time constants. iii) In six pigs during CPR with various tidal volumes, a CO2 pattern of thoracic distension, but not tidal volume per se, was associated with a significant decrease in blood pressure and cerebral perfusion. Conclusions: During CPR, intrathoracic airway closure, thoracic distension or regular pattern can be identified by capnogram analysis. A thoracic distension pattern on the capnogram may indicate a negative impact of ventilation on blood pressure and cerebral perfusion during CPR, not predicted by tidal volume per se.
- Open Access
- 1 May 2021
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 18 (5) , 857-864
Response to Ventilator Adjustments for Predicting Acute Respiratory Distress Syndrome Mortality. Driving Pressure versus Oxygenation
Rationale: Clinicians commonly use short-term physiologic markers to assess the benefit of ventilator adjustments. Improved arterial oxygen tension/pressure (PaO2)/fraction of inspired oxygen (Fi O2) after ventilator adjustment in acute respiratory distress syndrome is associated with lower mortality. However, as driving pressure (ΔP) reflects lung stress and strain, changes in ΔP may more accurately reflect benefits or harms of ventilator adjustments compared with changes in oxygenation. Objectives: We aimed to compare the association between mortality and the changes in PaO2/Fi O2 and ΔP following protocolized ventilator changes. Methods: We assessed associations between mortality and changes in PaO2/Fi O2 (ΔPaO2/Fi O2) and ΔP (ΔΔP) after postrandomization positive end-expiratory pressure (PEEP) and tidal volume adjustment in reanalyses of the ALVEOLI (Assessment of Low Tidal Volume and Elevated End-Expiratory Volume to Obviate Lung Injury) and ExPress (Expiratory Pressure) trials. We included subjects with available pre- and postintervention PaO2/Fi O2 and ΔP (372 in ALVEOLI and 596 in ExPress). In each separate trial cohort, we performed multivariable Cox regression testing the association between ΔPaO2/Fi O2 and ΔΔP with mortality. Results: In ALVEOLI, when analyzed as separate variables, ΔPaO2/Fi O2 was associated with mortality only in subjects in whom PEEP increased, whereas ΔΔP was associated with mortality irrespective of direction of PEEP change. When modeled together, improved ΔPaO2/Fi O2 was not associated with mortality, whereas ΔΔP remained associated with mortality (adjusted hazard ratio [aHR], 1.50 per 5 cm H2O increase; 95% confidence interval [95% CI], 1.21–1.85). When modeled together in ExPress, ΔΔP (aHR, 1.42; 95% CI, 1.14–1.78) was more strongly associated with mortality than ΔPaO2/Fi O2 (aHR, 0.95 per 25 mm Hg increase; 95% CI, 0.90–1.00). Conclusions: Reduced ΔP following protocolized ventilator changes was more strongly and consistently associated with lower mortality than was increased PaO2/Fi O2, making ΔΔP more informative about benefit from ventilator adjustments. Our results reinforce the primacy of ΔP, rather than oxygenation, as the key variable associated with outcome.
- 1 May 2021
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 18 (5) , 857-864
Open AccessResponse to Ventilator Adjustments for Predicting Acute Respiratory Distress Syndrome Mortality. Driving Pressure versus Oxygenation
Rationale: Clinicians commonly use short-term physiologic markers to assess the benefit of ventilator adjustments. Improved arterial oxygen tension/pressure (PaO2)/fraction of inspired oxygen (Fi O2) after ventilator adjustment in acute respiratory distress syndrome is associated with lower mortality. However, as driving pressure (ΔP) reflects lung stress and strain, changes in ΔP may more accurately reflect benefits or harms of ventilator adjustments compared with changes in oxygenation. Objectives: We aimed to compare the association between mortality and the changes in PaO2/Fi O2 and ΔP following protocolized ventilator changes. Methods: We assessed associations between mortality and changes in PaO2/Fi O2 (ΔPaO2/Fi O2) and ΔP (ΔΔP) after postrandomization positive end-expiratory pressure (PEEP) and tidal volume adjustment in reanalyses of the ALVEOLI (Assessment of Low Tidal Volume and Elevated End-Expiratory Volume to Obviate Lung Injury) and ExPress (Expiratory Pressure) trials. We included subjects with available pre- and postintervention PaO2/Fi O2 and ΔP (372 in ALVEOLI and 596 in ExPress). In each separate trial cohort, we performed multivariable Cox regression testing the association between ΔPaO2/Fi O2 and ΔΔP with mortality. Results: In ALVEOLI, when analyzed as separate variables, ΔPaO2/Fi O2 was associated with mortality only in subjects in whom PEEP increased, whereas ΔΔP was associated with mortality irrespective of direction of PEEP change. When modeled together, improved ΔPaO2/Fi O2 was not associated with mortality, whereas ΔΔP remained associated with mortality (adjusted hazard ratio [aHR], 1.50 per 5 cm H2O increase; 95% confidence interval [95% CI], 1.21–1.85). When modeled together in ExPress, ΔΔP (aHR, 1.42; 95% CI, 1.14–1.78) was more strongly associated with mortality than ΔPaO2/Fi O2 (aHR, 0.95 per 25 mm Hg increase; 95% CI, 0.90–1.00). Conclusions: Reduced ΔP following protocolized ventilator changes was more strongly and consistently associated with lower mortality than was increased PaO2/Fi O2, making ΔΔP more informative about benefit from ventilator adjustments. Our results reinforce the primacy of ΔP, rather than oxygenation, as the key variable associated with outcome.
- Open Access
Reliability and limits of transport-ventilators to safely ventilate severe patients in special surge situations
Background: Several Intensive Care Units (ICU) have been overwhelmed by the surge of COVID-19 patients thus necessitating to extend ventilation capacity outside the ICU where air and oxygen pressure are not always available. Transport ventilators requiring only O 2 source may be used to deliver volume-controlled ventilation. Objective: To evaluate the performances of four transport ventilators compared to an ICU ventilator simulating severe respiratory conditions. Materials and methods: Two pneumatic transport ventilators, (Oxylog 3000, Draeger; Osiris 3, Air Liquide Medical Systems) and two turbine transport ventilators (Elisee 350, ResMed; Monnal T60, Air Liquide Medical Systems) were compared to an ICU ventilator (Engström Carestation – GE Healthcare) using a Michigan training test lung. We tested each ventilator with different set volumes Vt set (350, 450, 550 ml) and different compliances (20 or 50 ml/cmH 2 O) and a resistance of 15 cmH 2 0/L/sec based on values recently described in COVID-19 Acute Respiratory Distress Syndrome. Volume error was measured, as well as the trigger time delay during assist-control ventilation simulating spontaneous breathing activity with a P 0.1 of 4 cmH 2 0. Results: Grouping all conditions, the volume error was 2.9 ± 2.2 % for Engström Carestation; 3.6 ± 3.9 % for Osiris 3; 2.5 ± 2.1 % for Oxylog 3000; 5.4 ± 2.7 % for Monnal T60 and 8.8 ± 4.8 % for Elisee 350. Grouping all conditions, trigger delay was 42 ± 4 ms, 65 ± 5 ms, 151 ± 14 ms, 51 ± 6 and 64 ± 5 ms for Engström Carestation, Osiris 3, Oxylog 3000, Monnal T60 and Elisee 350, respectively. Conclusions: In special surge situations such as COVID-19 pandemic, most transport ventilators may be used to safely deliver volume-controlled ventilation in locations where only oxygen pressure supply is available with acceptable volume accuracy. Performances regarding triggering function are generally acceptable but vary across ventilators.
Open AccessReliability and limits of transport-ventilators to safely ventilate severe patients in special surge situations
Background: Several Intensive Care Units (ICU) have been overwhelmed by the surge of COVID-19 patients thus necessitating to extend ventilation capacity outside the ICU where air and oxygen pressure are not always available. Transport ventilators requiring only O 2 source may be used to deliver volume-controlled ventilation. Objective: To evaluate the performances of four transport ventilators compared to an ICU ventilator simulating severe respiratory conditions. Materials and methods: Two pneumatic transport ventilators, (Oxylog 3000, Draeger; Osiris 3, Air Liquide Medical Systems) and two turbine transport ventilators (Elisee 350, ResMed; Monnal T60, Air Liquide Medical Systems) were compared to an ICU ventilator (Engström Carestation – GE Healthcare) using a Michigan training test lung. We tested each ventilator with different set volumes Vt set (350, 450, 550 ml) and different compliances (20 or 50 ml/cmH 2 O) and a resistance of 15 cmH 2 0/L/sec based on values recently described in COVID-19 Acute Respiratory Distress Syndrome. Volume error was measured, as well as the trigger time delay during assist-control ventilation simulating spontaneous breathing activity with a P 0.1 of 4 cmH 2 0. Results: Grouping all conditions, the volume error was 2.9 ± 2.2 % for Engström Carestation; 3.6 ± 3.9 % for Osiris 3; 2.5 ± 2.1 % for Oxylog 3000; 5.4 ± 2.7 % for Monnal T60 and 8.8 ± 4.8 % for Elisee 350. Grouping all conditions, trigger delay was 42 ± 4 ms, 65 ± 5 ms, 151 ± 14 ms, 51 ± 6 and 64 ± 5 ms for Engström Carestation, Osiris 3, Oxylog 3000, Monnal T60 and Elisee 350, respectively. Conclusions: In special surge situations such as COVID-19 pandemic, most transport ventilators may be used to safely deliver volume-controlled ventilation in locations where only oxygen pressure supply is available with acceptable volume accuracy. Performances regarding triggering function are generally acceptable but vary across ventilators.