Jan Schmidt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jan Schmidt has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Petr Fišer
CTU in Prague,Dept. of Digital Design,Prague,Czech Republic
3 shared publications - Ernst Klar
Department of General, Visceral, Vascular and Transplantation Surgery, University Medical Center Rostock, Rostock, Germany
2 shared publications M. M. Gebhard
Chirurgische Universitätsklinik Heidelberg
2 shared publicationsMiroslav Skrbek
CTU in Prague,Dept. of Digital Design,Prague,Czech Republic
2 shared publicationsC. Herfarth
Experimentelle Chirurgie der Universität Heidelberg
1 shared publication- Christian Blockhaus
Heart Centre Niederrhein, Department of Cardiology, Helios Clinic Krefeld, 47805 Krefeld, Germany
1 shared publication
Latest Publications
- 1 August 2024
- Published by Walter de Gruyter GmbH in it - Information Technology
- Vol. 66 (4-5) , 103-113
Structural bias in synthesis of sparsely-specified functions
Two-level logic minimization is a well-established process that efficiently minimizes functions described in the Sum-of-Products (SOP) form. Current two-level SOP minimizes, like Espresso and Boom, produce optimum or near-optimum results regarding the SOP size. However, in this article we show that an SOP minimization conducted in the standard, multi-output way, significantly worsens the result of the subsequent multi-level synthesis, especially for sparsely-specified functions, regardless of the optimization process and the tool used. In conclusion, we propose using a single-output two-level SOP minimization for sparsely specified functions. In this way, the obtained circuits are sometimes multiple times smaller, while no significant deterioration has been observed for any other functions.
- 1 August 2024
- Published by Walter de Gruyter GmbH in it - Information Technology
- Vol. 66 (4-5) , 103-113
Structural bias in synthesis of sparsely-specified functions
Two-level logic minimization is a well-established process that efficiently minimizes functions described in the Sum-of-Products (SOP) form. Current two-level SOP minimizes, like Espresso and Boom, produce optimum or near-optimum results regarding the SOP size. However, in this article we show that an SOP minimization conducted in the standard, multi-output way, significantly worsens the result of the subsequent multi-level synthesis, especially for sparsely-specified functions, regardless of the optimization process and the tool used. In conclusion, we propose using a single-output two-level SOP minimization for sparsely specified functions. In this way, the obtained circuits are sometimes multiple times smaller, while no significant deterioration has been observed for any other functions.
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 86-91
A Comparison of Logic Extraction Methods in Hardware-Translated Neural Networks
Small quantized neural networks with strong requirements on throughput and latency can be translated into logic circuits and synthesized by logic design tools. With networks having no state (memory), the circuits are combinational. To capture the function of the network (or a part of it) as a logic function, two approaches have been taken. The first one observes the inputs and outputs, while the network predicts a training set, and uses them directly as specification. The response to activation values that have not occurred in the training set remains unspecified. The other approach uses a complete set of activation values at the input of the examined part. We measured accuracy, the influence of logic minimization, and their impact on the final synthesized circuit on dense neural networks in different stages of low-magnitude pruning on the MNIST and JSC datasets. The results show that the first method can be used for functions with fan-in below 10–12 while not working against generalization. We also document the quantitative changes in quantized networks.
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 86-91
A Comparison of Logic Extraction Methods in Hardware-Translated Neural Networks
Small quantized neural networks with strong requirements on throughput and latency can be translated into logic circuits and synthesized by logic design tools. With networks having no state (memory), the circuits are combinational. To capture the function of the network (or a part of it) as a logic function, two approaches have been taken. The first one observes the inputs and outputs, while the network predicts a training set, and uses them directly as specification. The response to activation values that have not occurred in the training set remains unspecified. The other approach uses a complete set of activation values at the input of the examined part. We measured accuracy, the influence of logic minimization, and their impact on the final synthesized circuit on dense neural networks in different stages of low-magnitude pruning on the MNIST and JSC datasets. The results show that the first method can be used for functions with fan-in below 10–12 while not working against generalization. We also document the quantitative changes in quantized networks.
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 130-135
Adaptive Input Normalization for Quantized Neural Networks
Neural networks with quantized activation functions cannot adapt the quantization at the input of their first layer. Preprocessing is therefore required to adapt the range of input data to the quantization range. Such preprocessing usually includes an activation-wise linear transformation and is steered by the properties of the training set. We suggest to include the linear transform into the training process. Using the Jet Stream Classification task and an evaluation architecture of three quantized dense layers, we document that it improves accuracy, requires the same resources as standard preprocessing, plays a role in network pruning, and is reasonably stable with respect to initialization.
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 130-135
Adaptive Input Normalization for Quantized Neural Networks
Neural networks with quantized activation functions cannot adapt the quantization at the input of their first layer. Preprocessing is therefore required to adapt the range of input data to the quantization range. Such preprocessing usually includes an activation-wise linear transformation and is steered by the properties of the training set. We suggest to include the linear transform into the training process. Using the Jet Stream Classification task and an evaluation architecture of three quantized dense layers, we document that it improves accuracy, requires the same resources as standard preprocessing, plays a role in network pruning, and is reasonably stable with respect to initialization.
- Open Access
- 10 June 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (suppl_1) , i119
176-08: Break of circular catheter stuck in a right-inferior pulmonary vein during cryoballon pulmonary vein isolation
Case Report: We report a fifty-year-old male with paroxysmal atrial fibrillation presenting with EHRA III symptoms who underwent pulmonary vein isolation (PVI). The PVI was planned with a 28mm cryoballon under deep sedation. After uncomplicated transseptal puncture, angiography of the left atrium (LA) was done showing four independent pulmonary veins (PV). Heparin was given to maintain an activated clotting time of >300s. Following successful left PV isolation, the circular diagnostic catheter (CDC) was advanced in the right inferior PV (RIPV) and one successful freeze was delivered. After thawing of the cryoballon, it turned out not to be possible to remove the CDC from the RIPV. The fluoroscopy showed that the CDC was stuck in a small branch of the RIPV. While pulling the CDC the patient started to cough. The surrounding lung tissues seemed to be tightened and dragged together with the CDC. While turning the CDC, the shaft of the CDC broke close to the holder of the steerable sheath. With use of the remaining shaft, we further tried to remove the CDC from the PV, however, the CDC was again completely torn from the base of the circular part in the branch of RIPV. We then removed the proximal shaft and isolated the superior right PV with one freeze using a newly unpacked CDC. Final LA angiography demonstrated neither obstructions of major PVs nor exit of contrast agent out of LA, although the circular part of the CDC remained in the small branch of RIPV. After the procedure the patient showed no complaints such as cough, dyspnea or other symptoms. A pericardial effusion was also excluded. Discussion: Due to the tying in a small branch of the RIPV the CDC was stuck and we could not recover the catheter anymore. No practical way to resolve this situation has been described yet. Further catheter pulling was not an option due to the risk of a fatal bleeding because the surrounding lung tissue was tied. Another option could be an open-heart surgery. As the remaining part of the catheter did not move at all, we decided to leave the remaining circular part after a consultation with heart surgery unit. After a follow-up of one month the patient showed neither AF event nor clinical symptoms such as cough, dyspnea. We here reported a break of the CDC shaft during PVI with cryoballoon, which has been not yet reported.
- 10 June 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (suppl_1) , i119
Open Access176-08: Break of circular catheter stuck in a right-inferior pulmonary vein during cryoballon pulmonary vein isolation
Case Report: We report a fifty-year-old male with paroxysmal atrial fibrillation presenting with EHRA III symptoms who underwent pulmonary vein isolation (PVI). The PVI was planned with a 28mm cryoballon under deep sedation. After uncomplicated transseptal puncture, angiography of the left atrium (LA) was done showing four independent pulmonary veins (PV). Heparin was given to maintain an activated clotting time of >300s. Following successful left PV isolation, the circular diagnostic catheter (CDC) was advanced in the right inferior PV (RIPV) and one successful freeze was delivered. After thawing of the cryoballon, it turned out not to be possible to remove the CDC from the RIPV. The fluoroscopy showed that the CDC was stuck in a small branch of the RIPV. While pulling the CDC the patient started to cough. The surrounding lung tissues seemed to be tightened and dragged together with the CDC. While turning the CDC, the shaft of the CDC broke close to the holder of the steerable sheath. With use of the remaining shaft, we further tried to remove the CDC from the PV, however, the CDC was again completely torn from the base of the circular part in the branch of RIPV. We then removed the proximal shaft and isolated the superior right PV with one freeze using a newly unpacked CDC. Final LA angiography demonstrated neither obstructions of major PVs nor exit of contrast agent out of LA, although the circular part of the CDC remained in the small branch of RIPV. After the procedure the patient showed no complaints such as cough, dyspnea or other symptoms. A pericardial effusion was also excluded. Discussion: Due to the tying in a small branch of the RIPV the CDC was stuck and we could not recover the catheter anymore. No practical way to resolve this situation has been described yet. Further catheter pulling was not an option due to the risk of a fatal bleeding because the surrounding lung tissue was tied. Another option could be an open-heart surgery. As the remaining part of the catheter did not move at all, we decided to leave the remaining circular part after a consultation with heart surgery unit. After a follow-up of one month the patient showed neither AF event nor clinical symptoms such as cough, dyspnea. We here reported a break of the CDC shaft during PVI with cryoballoon, which has been not yet reported.
- 1 January 1997
- Published by Springer Nature
- p. 407-411
Oktreotid reduziert den Blutfluß in minderperfundierten Arealen des Pankreas bei akuter Pankreatitis
- 1 January 1997
- Published by Springer Nature
- p. 407-411
Oktreotid reduziert den Blutfluß in minderperfundierten Arealen des Pankreas bei akuter Pankreatitis