CSCarmen Salvador-Ribés

Carmen Salvador-Ribés

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Carmen Salvador-Ribés has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Consuelo Olivas

    Medical Imaging Department, La Fe University and Polytechnic Hospital, Valencia, Spain

    2 shared publications
  • Carina Soler-Pons

    Biomedical Imaging Research Group (GIBI230), La Fe Health Research Institute, Valencia, Spain

    1 shared publication
  • Dimos Baltas

    Division of Medical Physics, Department of Radiation Oncology, Faculty of Medicine, University Medical Center Freiburg, Freiburg, Germany

    1 shared publication
  • Irene Torres-Espallardo

    Medical Imaging Department, La Fe University and Polytechnic Hospital, Valencia, Spain

    1 shared publication
  • Irene Torres-Espallardo

    Nuclear Medicine Department and Clinical Area of Medical Imaging, Hospital Universitario y Politécnico La Fe, Valencia, Spain

    1 shared publication
  • José Pérez-Calatayud

    Department of Radiation Oncology, La Fe University and Polytechnic Hospital, Valencia, Spain

    1 shared publication

Latest Publications

  • Open Access

    Open-source phantom with dedicated in-house software for image quality assurance in hybrid PET systems

    by Carmen Salvador-Ribés, Carina Soler-Pons, María Jesús Sánchez-García, Tobias Fechter, Consuelo Olivas, Irene Torres-Espallardo, José Pérez-Calatayud, Dimos Baltas, Michael Mix, Luis Martí-Bonmatí, et al.

    Patients’ diagnosis, treatment and follow-up increasingly rely on multimodality imaging. One of the main limitations for the optimal implementation of hybrid systems in clinical practice is the time and expertise required for applying standardized protocols for equipment quality assurance (QA). Experimental phantoms are commonly used for this purpose, but they are often limited to a single modality and single quality parameter, lacking automated analysis capabilities. In this study, we developed a multimodal 3D-printed phantom and software for QA in positron emission tomography (PET) hybrid systems, with computed tomography (CT) or magnetic resonance (MR), by assessing signal, spatial resolution, radiomic features, co-registration and geometric distortions. Phantom models and Python software for the proposed QA are available to download, and a user-friendly plugin compatible with the open-source 3D-Slicer software has been developed. The QA viability was proved by characterizing a Philips-Gemini-TF64-PET/CT in terms of signal response (mean, µ), intrinsic variability for three consecutive measurements (daily variation coefficient, CoVd) and reproducibility over time (variation coefficient across 5 months, CoVm). For this system, averaged recovery coefficient for activity concentration was µ = 0.90 ± 0.08 (CoVd = 0.6%, CoVm = 9%) in volumes ranging from 7 to 42 ml. CT calibration-curve averaged over time was $$\text{HU}=(951\pm 12)\times \text{density}-(944\pm 15)$$ with variability of slope and y-intercept of (CoVd = 0.4%, CoVm = 1.2%) and (CoVd = 0.4%, CoVm = 1.6%), respectively. Radiomics reproducibility resulted in (CoVd = 18%, CoVm = 30%) for PET and (CoVd = 15%, CoVm = 22%) for CT. Co-registration was assessed by Dice-Similarity-Coefficient (DSC) along 37.8 cm in superior-inferior (z) direction (well registered if DSC ≥ 0.91 and Δz ≤ 2 mm), resulting in 3/7 days well co-registered. Applicability to other scanners was additionally proved with Philips-Vereos-PET/CT (V), Siemens-Biograph-Vison-600-PET/CT (S) and GE-SIGNA-PET/MR (G). PET concentration accuracy was (µ = 0.86, CoVd = 0.3%) for V, (µ = 0.87, CoVd = 0.8%) for S, and (µ = 1.10, CoVd = 0.34%) for G. MR(T2) was well co-registered with PET in 3/4 cases, did not show significant distortion within a transaxial diameter of 27.8 cm and along 37 cm in z, and its radiomic variability was CoVd = 13%. Open-source QA protocol for PET hybrid systems has been presented and its general applicability has been proved. This package facilitates simultaneously simple and semi-automated evaluation for various imaging modalities, providing a complete and efficient QA solution.


  • Open Access

    Control de calidad para PET/RM basado en maniquíes experimentales con evaluación de factores de degradación por movimiento respiratorio

    by Carmen Salvador-Ribés, África Almendros-Riaza, Consuelo Olivas, María del Pilar Morcillo-Toledo, Irene Torres-Espallardo, Sonia Ginés-Cárdenas, Pilar Bello, Moisés Sáez-Beltrán, Luís Martí-Bonmatí, Montserrat Carles

    El objetivo de este estudio es crear una prueba de control de calidad (CC) basada en maniquíes experimentales para equipos híbridos PET/RM. Se ha validado un método que minimiza el error en los mapas de atenuación (MA) para medidas de maniquíes con PET/RM, y se ha implementado en el CC para evaluar el impacto de distintos factores de degradación por movimiento respiratorio. Se empleó el maniquí MRI-QUASAR-Motion con insertos de impresión-3D, así como la herramienta Duetto para generar los MA a partir de tomografías computarizadas (MA-TC). Mediante coeficientes de recuperación (CR), se cuantificó el impacto de la compensación de movimiento en los MA, la discriminación de ciclos irregulares y el promediado para las fases respiratorias co-registradas en imágenes PET. No se observaron mejoras significativas al compensar el movimiento en los MA (p=0.31) ni al discriminar ciclos irregulares (p=0.16). Tampoco se observaron diferencias significativas entre estimar la concentración en cada fase respiratoria y promediar su valor (RCconcentración=0.982±0.013) o estimarlo en la imagen promedio de las fases respiratorias (RCconcentración=0.978±0.009). Nuestra prueba de CC permite recomendar evitar el postproceso que implica la compensación de movimiento respiratorio en los MA, la discriminación de ciclos respiratorios irregulares y el co-registro de las fases respiratorias.