Zygmunt Szefliński
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zygmunt Szefliński has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Beata Brzozowska
University of Warsaw
2 shared publications - Aleksandr Bancer
National Centre for Nuclear Research, 05-400 Otwock, Poland
1 shared publication Andrzej Rafalski
1 shared publication- Antoni Rucinski
Institute of Nuclear Physics PAS, Radzikowskiego 152, Krakow, 31-342, POLAND
1 shared publication - Bartłomiej Kociński
Biomedical Physics Division, Institute of Experimental Physics, Faculty of Physics , University of Warsaw , Poland
1 shared publication - Beata Pszczółkowska
Affiliation Biomedical Physics Division, Faculty of Physics, University of Warsaw, Warsaw, Poland
1 shared publication
Latest Publications
- Open Access
- 4 September 2025
- Published by Elsevier in Environmental and Experimental Botany
- Vol. 240
Influence of ploidy on radiation resilience in extremophilic alga Galdieria sulphuraria under extreme ionizing conditions
- 4 September 2025
- Published by Elsevier in Environmental and Experimental Botany
- Vol. 240
Open AccessInfluence of ploidy on radiation resilience in extremophilic alga Galdieria sulphuraria under extreme ionizing conditions
- Open Access
- 1 June 2024
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 30 (2) , 79-89
From radiobiology to radiotherapy: dose homogeneity in cells after alpha irradiation in measurements and Monte Carlo simulations
Introduction: Proton radiotherapy offers an advantage in sparing healthy tissue compared to photon therapy due to the specific interaction of protons with the patient’s body. In radiobiological experiments, alpha sources are commonly used instead of proton accelerators for convenience, but ensuring a uniform dose distribution is challenging. Properly designing the cell irradiation setup is crucial to reliably measure the average cellular response in such experiments. The objective of this research is to underscore the importance of dosimetric validation in radiobiological investigations. While Monte Carlo (MC) simulations offer valuable insights, their accuracy needs experimental confirmation. Once consistent results are obtained, the reliance on simulations becomes viable, as they are more efficient and less cumbersome compared to experimental procedures. Material and methods: The simulations are performed with three MC code-based tools: Geant4-DNA, GATE, and SRIM to model the alpha radiation source and calculate dose distributions for various cell irradiation scenarios. Dosimetric verification of the experimental setup containing a 241 Am source is performed using radiochromic films. Additionally, a clonogenic cell survival assay is carried out for the DU145 cell line. Results: The study introduces a novel source simulation model derived from dosimetric measurements. The comparison between dosimetric results obtained with simulations and measured experimentally yields a gamma (3%/3mm) parameter value exceeding 99%. Furthermore, the LQ model parameters fitted to survival data of DU145 cells irradiated with particles emitted from 241 Am source demonstrate consistency with previously published findings. Conclusions: Radiobiological experiments investigate cellular responses to various irradiation scenarios. Challenges arise with densely ionizing radiation used in clinical practice, particularly in ensuring uniform dose delivery for reliable experiments. MC codes aid in simulating dose distribution and designing irradiation systems for consistent cell treatment. However, experimental validation is essential before relying on simulation results. Once confirmed, these results offer a cost-effective and time-efficient approach to planning radiobiological experiments compared to traditional laboratory work.
- 1 June 2024
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 30 (2) , 79-89
Open AccessFrom radiobiology to radiotherapy: dose homogeneity in cells after alpha irradiation in measurements and Monte Carlo simulations
Introduction: Proton radiotherapy offers an advantage in sparing healthy tissue compared to photon therapy due to the specific interaction of protons with the patient’s body. In radiobiological experiments, alpha sources are commonly used instead of proton accelerators for convenience, but ensuring a uniform dose distribution is challenging. Properly designing the cell irradiation setup is crucial to reliably measure the average cellular response in such experiments. The objective of this research is to underscore the importance of dosimetric validation in radiobiological investigations. While Monte Carlo (MC) simulations offer valuable insights, their accuracy needs experimental confirmation. Once consistent results are obtained, the reliance on simulations becomes viable, as they are more efficient and less cumbersome compared to experimental procedures. Material and methods: The simulations are performed with three MC code-based tools: Geant4-DNA, GATE, and SRIM to model the alpha radiation source and calculate dose distributions for various cell irradiation scenarios. Dosimetric verification of the experimental setup containing a 241 Am source is performed using radiochromic films. Additionally, a clonogenic cell survival assay is carried out for the DU145 cell line. Results: The study introduces a novel source simulation model derived from dosimetric measurements. The comparison between dosimetric results obtained with simulations and measured experimentally yields a gamma (3%/3mm) parameter value exceeding 99%. Furthermore, the LQ model parameters fitted to survival data of DU145 cells irradiated with particles emitted from 241 Am source demonstrate consistency with previously published findings. Conclusions: Radiobiological experiments investigate cellular responses to various irradiation scenarios. Challenges arise with densely ionizing radiation used in clinical practice, particularly in ensuring uniform dose delivery for reliable experiments. MC codes aid in simulating dose distribution and designing irradiation systems for consistent cell treatment. However, experimental validation is essential before relying on simulation results. Once confirmed, these results offer a cost-effective and time-efficient approach to planning radiobiological experiments compared to traditional laboratory work.
- Open Access
- 7 May 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (10) , 5094
Ionization Detail Parameters for DNA Damage Evaluation in Charged Particle Radiotherapy: Simulation Study Based on Cell Survival Database
Details of excitation and ionization acts hide a description of the biological effects of charged particle traversal through living tissue. Nanodosimetry enables the introduction of novel quantities that characterize and quantify the particle track structure while also serving as a foundation for assessing biological effects based on this quantification. This presents an opportunity to enhance the planning of charged particle radiotherapy by taking into account the ionization detail. This work uses Monte Carlo simulations with Geant4-DNA code for a wide variety of charged particles and their radiation qualities to analyze the distribution of ionization cluster sizes within nanometer-scale volumes, similar to DNA diameter. By correlating these results with biological parameters extracted from the PIDE database for the V79 cell line, a novel parameter based on ionization details is proposed for the evaluation of radiation quality in terms of biological consequences, i.e., radiobiological cross section for inactivation. By incorporating the probability p of sub-lethal damage caused by a single ionization, we address limitations associated with the usually proposed nanodosimetric parameter for characterizing the biological effects of radiation. We show that the new parameter correlates well with radiobiological data and can be used to predict biological outcomes.- 7 May 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (10) , 5094
Open AccessIonization Detail Parameters for DNA Damage Evaluation in Charged Particle Radiotherapy: Simulation Study Based on Cell Survival Database
Details of excitation and ionization acts hide a description of the biological effects of charged particle traversal through living tissue. Nanodosimetry enables the introduction of novel quantities that characterize and quantify the particle track structure while also serving as a foundation for assessing biological effects based on this quantification. This presents an opportunity to enhance the planning of charged particle radiotherapy by taking into account the ionization detail. This work uses Monte Carlo simulations with Geant4-DNA code for a wide variety of charged particles and their radiation qualities to analyze the distribution of ionization cluster sizes within nanometer-scale volumes, similar to DNA diameter. By correlating these results with biological parameters extracted from the PIDE database for the V79 cell line, a novel parameter based on ionization details is proposed for the evaluation of radiation quality in terms of biological consequences, i.e., radiobiological cross section for inactivation. By incorporating the probability p of sub-lethal damage caused by a single ionization, we address limitations associated with the usually proposed nanodosimetric parameter for characterizing the biological effects of radiation. We show that the new parameter correlates well with radiobiological data and can be used to predict biological outcomes.